Inverter dust handling – Reynolds inverters

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

1. Plan a special inverter room: When the power of the inverter used is large or the number is large, a special inverter room can be planned. The doors, windows and cable holes in the room should be sealed to prevent dust from entering; It is necessary to plan air filtration equipment and circulation channels to adhere to the normal circulation of indoor air; Make sure the indoor temperature is below 40°C. Unified management, which is conducive to viewing and maintenance.

                              Inverter dust handling – Reynolds inverters

2. Installed in a cabinet with fans and filtration equipment: when the user does not have the conditions to set up a special inverter room, the dust cabinet can be considered. Fans and filters should be planned to ensure sufficient air flow in the cabinet. The user should check the fan on time to eradicate the dust on the filter screen and avoid the temperature exceeding the specified value due to the lack of ventilation.

3. The selection of dustproof inverters can be stronger: when selecting the specifications and models of inverters on the market, in addition to the quotation and function, the adaptability to the environment should also be considered. Some inverters do not have a cooling fan, relying on its shell to naturally dissipate heat in the air, compared with the air-cooled inverter, although the volume is larger, but the sealing function of the device is good, not affected by dust, the maintenance is simple, the failure rate is low, the operation life is long, and it is particularly suitable for the use of corrosive industrial gases and dust.

4. Reduce the no-load operation time of the inverter: In the industrial production process, the general inverter is generally often connected to the power supply, and the start/stop and rotation direction of the motor are controlled by the "forward/reverse/common end" control terminal (or the button on the control panel) of the inverter. Some equipment may be open and stopped, and the fan is still working when the inverter is no-loaded, which will absorb dust, which is unnecessary. During the production operation, the no-load time of the inverter should be minimized to reduce the impact of dust on the inverter.

5. Establish the principle of punctual dust removal: the user should determine the time distance of punctual dust removal according to the influence of dust on the inverter. Dust collection can be done with an electric vacuum cleaner or compressed air. In the future, it is also necessary to pay attention to check the tumbling condition of the inverter fan and check whether the electrical connection points are loose and heated.

More on that
The difference between a soft starter and an inverter – Reynolds The difference between a soft starter and an inverter – Reynolds

The inverter changes the output frequency and voltage together, that is, changes the n0 on the motor running curve, so that the motor running curve moves parallel downward. Therefore, the inverter can make the motor reach its maximum torque with a small starting current, that is, the inverter can start the heavy-duty load.

Reynolds frequency converters are remotely controlled for wiring Reynolds frequency converters are remotely controlled for wiring

1. Connect X (switching input) drive terminal to control the inverter start-stop/positive rotation; 2. Connect to the AI (analog input) terminal to control the frequency of the inverter (perhaps made into PID closed-loop control automatic adjustment frequency) ​ 3. ...

The basic principle of vector control of frequency converters The basic principle of vector control of frequency converters

The basic principle of vector control is to control the excitation current and torque current of the asynchronous motor according to the principle of magnetic field orientation through the measurement and control of the stator current vector of the asynchronous motor, and then achieve the purpose of controlling the torque of the asynchronous motor. Specifically, the stator of the asynchronous motor ...

Reynolds inverter overhaul process Reynolds inverter overhaul process

1) Query and query fault phenomena. The fault phenomenon of the inverter is varied, for example, the same type of problem may have different problem phenomena, and different types of problems may have the same kind of problem, which brings difficulties to find the problem. However, the problem phenomenon is the fundamental basis for repairing the inverter ...

Introduction to the key components of the inverter - Reynolds Introduction to the key components of the inverter - Reynolds

There are many kinds of components of the inverter, different components have different functions, and different components have different specializations! In addition to the composition and application of Aideley inverter, there are also key components of inverter to provide for the operation of inverter.

Inverter composition and various functions - Reynolds Inverter composition and various functions - Reynolds

Rectifier circuit: rectify 50HZ communication power into direct current. Frequency conversion circuit: The rectified direct current is inverted into a variable frequency communication current. Control part: control the frequency of communication electricity output by the inverter circuit. Maintenance circuit: maintenance and blockage of overcurrent and phase loss ...

Precautions for installation of Reynolds low-voltage inverters Precautions for installation of Reynolds low-voltage inverters

1. Safety precautions 1. The primary requirement is to have certain electrical professional knowledge, and understand the job site, understand the equipment status, and have certain electrical operation technology. 2. Determine the electrical ...

Reynolds universal inverter start-up mode Reynolds universal inverter start-up mode

1. Direct launch The universal inverter insists on starting at the beginning of the time according to the set starting frequency and starting frequency, and then accelerates to a given frequency according to the selected acceleration time Second, the speed of the tracking start Universal inverter ...

Control method of Reynolds inverter Control method of Reynolds inverter

The fulfillment device commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system. Typical wiring method for the main circuit of a Reynolds frequency converter ...

Servo drive failure and solution Servo drive failure and solution

1. When the servo motor of the robot is running at a very low speed, it is fast and slow, just like a creeping machine. Low-speed prostrate servo motors are usually caused by low system gain. Please adjust the parameter N.10.N.11.N.12 to adjust the system gain appropriately, or the automatic gain adjustment function of the running driver ...

Inverter installation and heat dissipation treatment - Reynolds Inverter installation and heat dissipation treatment - Reynolds

The inverter has power loss during operation and converts it into heat energy, which increases its own temperature. Roughly speaking, the power loss of every 1kVA inverter capacity is about 40W-50W. Therefore, when installing the inverter, it is necessary to consider the heat dissipation of the inverter, and how to run the inverter.

Reynolds soft starter features: Reynolds soft starter features:

The Reynolds soft engine is a new type of software launcher that can assist users in quickly launching and closing the computer system. It was developed by Reynolds and its main function is to provide a fast, safe and reliable software launcher that can assist users in quickly launching and closing ...

Reynolds soft starter manual Reynolds soft starter manual

Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, and is a new type of starting equipment at the international advanced level. This product can effectively limit the starting current of asynchronous motor start-up, and is widely used in ...

Parameter setting of acceleration and deceleration time of Reynolds universal inverter Parameter setting of acceleration and deceleration time of Reynolds universal inverter

The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to drop from the high frequency to 0. Usually, the inverter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. When the motor accelerates, the rise of the frequency setting must be constrained ...

Frequency converters need to be replaced regularly – Reynolds Frequency converters need to be replaced regularly – Reynolds

The inverter is composed of many electronic parts, such as semiconductor components, etc., in the application and protection involves the replacement of a related component, because of the composition or physical characteristics of the inverter, it will deteriorate in a certain period of time, which will reduce the characteristics of the inverter, and even ...

Reynolds inverter control method Reynolds inverter control method

The actuator commonly used in the industrial field of Reynolds inverter has good speed regulation performance and simple and convenient operation method. Therefore, it is widely used in the automation system. Typical wiring method for the main circuit of a Reynolds frequency converter ...

The external configuration of the inverter is solved - Reynolds The external configuration of the inverter is solved - Reynolds

With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...

The inverter prepares the braking resistance factor – Reynolds The inverter prepares the braking resistance factor – Reynolds

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to avoid the capacitor voltage being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and avoid energy waste. However, the capacitance of the capacitor is ...

Inverter replacement component requirements - Reynolds Inverter replacement component requirements - Reynolds

1) Find out the basic parameters and appearance of the equipment that needs to be replaced. The basic parameters include the rated operating current, the capacitance of the capacitor, the resistance value of the resistor, the value of the GTR Darlington device (current amplification factor), the switching characteristics and saturation voltage of the IGBT (including IPM) device, etc.

Reynolds drives use the most energy-efficient method Reynolds drives use the most energy-efficient method

As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the additional power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical. But the conditions are: At the top of the list, great success ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top