Introducing the Reynolds JJR5000 series of soft starters

Create Date: 2024-8-30 12:03:23|Source: RENLE/RENOLDS

Reynolds JJR5000 series all-digital intelligent AC motor soft starter adopts power electronics technology, microprocessor technology and modern control theory technology, which is a new type of starting equipment at the current level. This product can limit the starting current of asynchronous motor start-up, and is widely used in heavy-duty equipment such as fans, pumps, conveyors, compressors, etc., and is an ideal alternative to step-down starting equipment such as star/delta conversion and auto-coupling step-down magnetron step-down. Typical application introduction.

                               Introducing the Reynolds JJR5000 series of soft starters

Water pump - use the soft stop function to alleviate the water hammer phenomenon when the pump is shut down, and save system maintenance costs.

Ball Mill – Utilizes voltage ramp start-up to reduce gear torque wear and reduce maintenance workload, i.e. save time and money.

Fan – reduces belt wear and mechanical shock, saving maintenance costs.

Compressor - use current limiting to achieve smooth start-up, reduce motor heat generation, and extend service life.

Crusher – Utilize clogging protection and quick protection to avoid mechanical failure or blockage that can cause the motor to overheat and burn out.

Conveyor Machinery – Smooth and gradual start-up with soft start to avoid product displacement and liquid spillage.

Features of the Reynolds JJR5000 series soft starters:

Three starting modes: the voltage ramp start mode can obtain the largest output torque, the constant current soft start mode can obtain the largest starting current limit, and the heavy-load start mode can be applied to the heavy-load mode.

Parking method: Voltage slope is soft, free parking.

Programmable delayed start mode, programmable interlock control.

No phase sequence requires input power.

The start time and stop time can be modified digitally.

Overcurrent, three-phase current unbalanced, overheated, phase missing, current unbalanced, overheated, phase missing functions.

Dynamic fault memory function, easy to find the cause of the fault, ** record five more faults.

You can find the largest starting current and the largest operating current online.

The fieldbus fully dynamic control monitoring starter is easy to network. (Optional)

Chinese character display function: the LCD screen displays various working condition parameters, and there are text prompts for programming and fault conditions.

More on that
Reynolds servo motor selection steps Reynolds servo motor selection steps

According to the requirements of the operating conditions, the appropriate load inertia accounting formula is selected to calculate the load inertia of the organization. According to the load inertia and servo motor inertia, the appropriate servo motor standard is selected. Combined with the inertia and load inertia of the primary servo motor, the acceleration torque and deceleration are calculated.

Renault is available in a variety of product ranges Renault is available in a variety of product ranges

JJR1000系列:   JJR1011;JJR1017;JJR1022;JJR1030;JJR1037;JJR1045;JJR1055;JJR1075;JJR1090;JJR1115;JJR1132;JJR1160;JJR1200;JJR1250;JJR1320;JJR1400;JJR1500;JJR1600 ...

The breaking capacity of the industrial control appliance switch The breaking capacity of the industrial control appliance switch

Assuming Icu=60KA, then when a faulty current of 60KA is generated in the line, the circuit breaker can safely cut off the circuit without abnormal conditions such as contact welding and blasting. Pay attention to the extreme breaking ...

The main circuit of the inverter is composed of Reynolds The main circuit of the inverter is composed of Reynolds

When it comes to inverter repair, it's not enough to understand the above fundamental circuits, but also to understand the following primary circuits. The main circuit is mainly composed of rectifier circuit, current limiting circuit, filter circuit, braking circuit, inverter circuit and detection and sampling circuit. ...

The inverter needs to rectify and then invert the cause - Reynolds The inverter needs to rectify and then invert the cause - Reynolds

Special inverter suppliers remind you that in daily industrial production, there are inverters that do not require rectifier units, which are the so-called alternating current inverters. However, the vast majority of the market is AC-DC-AC frequency converter, which also contains a rectifier unit, which is a certain level of technology and market competition.

General Purpose Inverter Repair Inspection – Reynolds General Purpose Inverter Repair Inspection – Reynolds

The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the ...

The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy The Reynolds booth was presented at the Industrial Automation Exhibition Center in Parma, Italy

Shanghai Reynolds Technology Co., Ltd. is an enterprise specializing in the design and production of high and low voltage soft starters, high and low voltage variable frequency speed regulation, intelligent electrical, new energy electrical and high and low voltage power transmission and transformation equipment, which are widely used in electric power, metallurgy, petroleum and petrochemical, military, mining, chemical industry, ...

The reason why the inverter burns the power supply inlet end - Reynolds The reason why the inverter burns the power supply inlet end - Reynolds

1. It is necessary to consider the touch and current size of the incoming terminal, if the terminal standard is small, perhaps the conductive function of the terminal is poor, which will directly cause the current carrying capacity of the terminal to be small and heated. 2. The inlet at the end of the inlet line must be pressed well and the like, if it is not pressed, it may cause ...

Inverter breakdown factor – Reynolds Inverter breakdown factor – Reynolds

1. Overpressure leads to brake pipe breakdown. The so-called overvoltage of the inverter refers to the fact that the inverter voltage composed of various reasons exceeds the additional voltage, which is reflected in the DC voltage of the inverter DC bus. Overvoltage alarm generally appears when the machine is shut down, and its main ...

The solution to the low or high output of the differential pressure transmitter – ifm The solution to the low or high output of the differential pressure transmitter – ifm

When the differential pressure flowmeter (V-cone flowmeter) is used in the field, it often encounters such and such problems, but the reason for it is investigated, as long as it is installed correctly, the primary problem is on the secondary surface differential pressure transmitter, and the following is the first to introduce these problems to us ...

The inverter uses a power-saving method – Reynolds The inverter uses a power-saving method – Reynolds

As an electronic electric, the inverter itself also consumes electricity (about 3-5% of the rated power). A 1.5 hp air conditioner consumes 20-30W of electricity, which is equivalent to the length of a lamp. The inverter works under the power frequency and has the function of saving electricity, which is practical. However, the conditions are: First, high power and ...

The external configuration of the inverter is solved - Reynolds The external configuration of the inverter is solved - Reynolds

With the improvement of the degree of automation of packaging machinery, packaging machine inverter (hereinafter referred to as VFD) plays an increasingly important role in packaging machinery. Capsule filling machine, high-speed tablet press, bottling production line, aluminum-plastic packaging machine, cartoning machine, each equipment will use VFD, mainly ...

Applicable mode of inverter maintenance - Reynolds inverter Applicable mode of inverter maintenance - Reynolds inverter

CNC cutting machine 1. Gradual reduction method The so-called gradual reduction method is to narrow the scope of shortcomings step by step by elaborating the shortcomings and judging the measurement parameters.

Parameter setting of acceleration and deceleration time of Reynolds universal inverter Parameter setting of acceleration and deceleration time of Reynolds universal inverter

The acceleration time of the Reynolds inverter is the time required for the output frequency to rise from 0 to the high frequency, and the deceleration time is the time required to decrease from the high frequency to 0. Generally, the frequency converter uses the frequency setting signal to rise and fall to confirm the acceleration and deceleration time. The rise of the frequency setting must be limited when the motor accelerates.

Reynolds inverter FAQ - parameter class Reynolds inverter FAQ - parameter class

1. What are the factory parameters of inverter rehabilitation? N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective. 2. In the parameters of the N308 motor of the inverter, [motor leakage inductance reactance] is the specified sub...

Inverter composition and various functions - Reynolds Inverter composition and various functions - Reynolds

Rectifier circuit: rectify 50HZ communication power into direct current. Frequency conversion circuit: The rectified direct current is inverted into a variable frequency communication current. Control part: control the frequency of communication electricity output by the inverter circuit. Maintenance circuit: maintenance and blockage of overcurrent and phase loss ...

The soft starter output is out of phase fault The soft starter output is out of phase fault

Soft Starter Repair Problem: F 04 (Input Phase Loss): There are several factors that cause this problem, some of which are listed below: (1) Check whether the wiring between the incoming power supply and the motor is loose; (2) Whether the output is connected to the load, and whether the load is matched with the motor; (3) ...

The difference between the voltage type and the current type of inverter - Reynolds The difference between the voltage type and the current type of inverter - Reynolds

Energy storage elements are different, the voltage type energy storage element is a capacitor, and the current type is an inductor. In fact, the general inverter uses power electronic circuits, which is a process of communication to DC - DC energy storage - DC to communication. It is also often said that the rectifier link --〉 energy storage link --〉 inverter ring ...

Inverter starts the overload adjustment parameter - Reynolds Inverter starts the overload adjustment parameter - Reynolds

Motor overload: There is no need to set overload maintenance parameters in frequency conversion. The inverter generally acquiesces to the motor overload maintenance based on the motor power. Generally, it is 1.2 times and 60 seconds will report an overload failure. The overload factor is not the same for different frequency converters. ...

Difference Between Soft Starter and Inverter – Reynolds Difference Between Soft Starter and Inverter – Reynolds

Soft starters and frequency converters are two completely different products. The inverter is used in the local area where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator, which is used when starting a motor, and the output only changes the voltage and does not change the frequency. Change...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top