The first step is to check whether the appearance of the inverter is defective, including whether the indicator light is in normal operation, whether the mission control function of the operation panel is complete, and carefully observe the appearance of the inverter under the operating condition, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the promised value range to prevent the inverter from overloading; If an abnormal situation is found, useful measures should be taken to prevent the problem from expanding, and the inverter problem should be quickly eliminated within the smallest range as far as possible.
The second step is to check whether the power supply equipment is operating normally and whether the fundamental line is damaged when repairing the inverter, so as to ensure that the line operation is always in a stable state; Check whether the cooling mechanism itself and its operation are safe and reliable, and whether the inverter is affected by grease and dust during operation. If too much grease and dust accumulate, it will directly block the operation of the air cooler, resulting in the deviation of the heat dissipation effect of the inverter, resulting in an abnormal increase in the temperature of the inverter, and causing the operation of the inverter. Therefore, it is necessary for the inverter to regularly clean the dust and oil around the cooler to ensure the smooth exhaust of the cooler.
The third step is to detect the heat dissipation and thermal conductivity of the inverter under the operating condition when the inverter is repaired, check whether the radiator is operating normally, do a good job in the daily maintenance of the radiator, sort out the dust on the radiator, and prevent the heat dissipation function of the inverter from being affected by dust accumulation; When installing the inverter, it is necessary to install it in accordance with the relevant specifications, select the device in the area of a good operating environment, eliminate the bad influence of the harsh environment on the operation of the inverter, and especially prevent the inverter from being installed in an environment with dusty, humid and corrosive substances.
|
More on that
|
Protection function of the Reynolds soft starter
1. Overload protection function: The soft starter introduces a current control loop, so that the change of motor current can be tracked and detected at any time. By increasing the setting of overload current and the anti-time control mode, the overload protection function is realized, so that when the motor is overloaded, the thyristor is turned off and an alarm signal is issued.
...
|
|
The way to set the parameters of the inverter - Reynolds
There are many setting parameters of the inverter, and each parameter has a certain range of choice, and the inverter can not work normally due to the improper setting of a single parameter in use, therefore, the relevant parameters must be set correctly.
...
|
|
How to measure a frequency converter with a multimeter – Reynolds
How to use a multimeter to measure the quality of the inverter, it needs to be noted that for personal safety, it is necessary to ensure that the machine is powered off, and remove the inverter input power line R, S, T and output line U, V, W before operation! First of all, the multimeter is hit to the "secondary pipe" file, and then through the multimeter ...
|
|
The main failure mode of mechanical parts – Reynolds
The top failure modes of mechanical parts:
Failure: The mechanical part cannot complete its normal function within the planning and booking period and under the regular conditions.
Ways in which mechanical parts fail: overall cracking, plastic deformation, corrosion, abrasion, gluing, and touch exhaustion
General ...
|
|
Features of the unit tandem inverter - Reynolds
(1) The multi-pronged PWM control method is selected, and the output voltage waveform is close to the sine wave.
(2) The rectifier circuit is multiplied, the number of pulses is as high as 36, the power factor is high, and the input harmonic is small.
(3) Modular design, compact structure ...
|
|
Two Reynolds technologies were included in the "2020 Water Conservancy Technology Key Promotion Catalogue"
In May 2020, Reynolds was recommended by relevant departments to apply for the Ministry of Water Resources's "2020 Key Promotion and Guidance Catalogue of Advanced and Practical Water Conservancy Technologies".
|
|
Inverter starts the overload adjustment parameter - Reynolds
Motor overload: There is no need to set overload maintenance parameters in frequency conversion.
The inverter generally acquiesces to the motor overload maintenance based on the motor power. Generally, it is 1.2 times and 60 seconds will report an overload failure. The overload factor is not the same for different frequency converters.
...
|
|
The difference between frequency converter and power saver - Reynolds
Many people don't have a clear idea of the detailed differences and uses of AC converters and power savers. Power savers are generally divided into lighting appliances and power savers. Using high-voltage filtering and energy absorption skills, it automatically absorbs the energy of the reverse potential of high-voltage power equipment, and continuously feeds back ...
|
|
Key points for the selection of AC contactors - Reynolds
1. Select varieties according to the above series according to the purpose and requirements of use
Note that the main circuit load type is strictly differentiated, whether it is DC or communication.
The communication contactor is different from the DC contactor, and is only suitable for DC-1 to DC-5 loads when used for DC loads.
|
|
The main circuit of the inverter is composed of Reynolds
When it comes to inverter repair, it's not enough to understand the above fundamental circuits, but also to understand the following primary circuits. The main circuit is mainly composed of rectifier circuit, current limiting circuit, filter circuit, braking circuit, inverter circuit and detection and sampling circuit.
...
|
|
Introducing the Reynolds JJR8000 series of intelligent soft starters
JJR8000 series of intelligent motor soft starter is the use of power electronics skills, microprocessor skills and modern control theory skills to produce today's international first-class starting equipment, the product can constrain the starting voltage of the asynchronous motor when starting, can be used in fans, water...
|
|
Features of electronic single-phase current transmitter – Reynolds
Single-phase current transmitter is a kind of electric power test substation developed for the power measurement of single-phase communication in motor experiments on the basis of motor experiment and testing technology research, in accordance with IEC and relevant national specifications for motor experiments. The use of advanced filtering technology, reasonable software algorithms, ...
|
|
Dust design considerations for frequency converters - Reynolds frequency converters
1) The air duct of the inverter cabinet should be planned reasonably, and the exhaust should be clear and smooth, so as to avoid the formation of vortex in the cabinet and the accumulation of dust in a fixed direction.
2) The top air outlet of the inverter cabinet should be equipped with a protective top cover to avoid debris from falling directly.
|
|
Progressive method of robustness of automatic control cabinets – Reynolds
1. Appropriate working environment
1. The ambient temperature is suitable
All manufacturers have certain rules for active temperature control cabinets. The PLC promises that the ambient temperature is usually about 0 to 55 ° C, so during the equipment process, this heating element is not placed in the PLC; The PLC should have adequate ventilation and ...
|
|
Rated current analysis of inverter leakage circuit breaker
The output of the inverter is controlled by PWM (pulse width modulation, similar to high-speed switching), so a high frequency leakage current will occur, if you want to install a general leakage disconnect switch on the primary side of the inverter, it is recommended to select a sensitivity current of more than 200mA for each inverter and the action time is 0.1 seconds ...
|
|
Inverter installation and heat dissipation treatment - Reynolds
The inverter has power loss during operation and converts it into heat energy, which increases its own temperature. Roughly speaking, the power loss of every 1kVA inverter capacity is about 40W-50W. Therefore, when installing the inverter, it is necessary to consider the heat dissipation of the inverter, and how to run the inverter.
|
|
Reynolds inverter parameter problem
1. What are the factory recovery parameters of Reynolds inverter?
N600 = 100 (often press the WR button for 3-5 seconds), it is necessary to be in the shutdown state to be effective.
2. In the parameters of the N308 motor of the inverter, is the [motor leakage inductance reactance] specified sub-leakage inductance or rotor leakage inductance react?
Decide...
|
|
Inverter control method - Reynolds
The output voltage of low-voltage general frequency conversion is 380-650V, the output power is 0.75-400kW, and the operating frequency is 0-400Hz. Its control methods have gone through the following four generations. 1U/f=C Sinusoidal Pulse Width Modulation (SPWM) Manipulation MethodIts Characteristics ...
|
|
Introduction to the function of the inverter - Reynolds inverter
In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to collect, distribute, and transmit electrical energy. The connection methods of the bus bar are ...
|
|
The heat dissipation method of Reynolds switching power supply
1. Transfer heat pipes for heat dissipation.
In many applications, the heat generated from the base steel plate of the power module is transferred through the heat transfer components to the distant heat pipe surface. In this way, the temperature of the base steel plate of the power module will be equal to the temperature of the heat pipe heat dissipation surface, the temperature of the heat transfer parts, and the temperature of the two contact ...
|
|