There are many setting parameters of the inverter, and each parameter has a certain range of choice, and the inverter can not work normally due to the improper setting of a single parameter in use, therefore, the relevant parameters must be set correctly.
First, the control method
i.e. speed control, rotation control, PID control, or other methods. After the control method is adopted, it is generally necessary to carry out static or dynamic identification according to the control accuracy.
Second, * low operating frequency
That is, the smallest speed of the motor operation, when the motor is running at low speed, its heat dissipation function is very poor, and the motor runs at low speed for a long time, which will cause the motor to burn out.
And at low speeds, the current in the cable will also increase, which will also cause the cable to heat up.
3. High operating frequency
The general frequency converter has a large frequency of 60Hz, and some even to 400Hz, and the high frequency will make the motor run at high speed, which is for the general motor, its bearing can not run beyond the rated speed for a long time, and whether the rotor of the motor can accept such centrifugal force.
Fourth, the carrier frequency
The higher the carrier frequency setting, the greater the weight of the higher harmonics, which is closely related to the length of the cable, the heating of the motor, the heating of the cable and the heating of the inverter.
5. Motor parameters
The inverter sets the power, current, voltage, speed, and maximum frequency of the motor in the parameters, and these parameters can be directly obtained from the motor nameplate.
6. Frequency hopping
At a certain frequency point, resonance may occur, especially when the whole device is relatively high; When operating the compressor, avoid the surge point of the compressor.
|
More on that
|
Safety standards for AC drives – Reynolds
International electrical safety standards: The requirements are in line with international electrical safety standards, such as CE standards in Europe and UL specifications in United States. These specifications specify the requirements for electrical safety functions, mechanical safety functions, EMC functions, etc.
...
|
|
The relationship between Reynolds motion control and frequency converters
Motion control has obvious period characteristics, it is a variety of high-tech generalization, used to push industrial automation, office automation and home automation to a higher stage. Nowadays, motion control is mainly composed of variable frequency drive (VFD), electric motor, control ...
|
|
The factor that causes the breakdown of the inverter – Reynolds
1. Overpressure leads to brake pipe breakdown.
The so-called overvoltage of the inverter refers to the fact that the inverter voltage formed due to various reasons exceeds the additional voltage, which is concentrated in the DC voltage of the inverter DC bus.
The overvoltage alarm generally appears at the time of shutdown, and its main ...
|
|
Soft start uses common faults and solutions - Reynolds
In the process of daily use of soft starters, it is inevitable to encounter some improper use or failure of soft starters in the process of use
1. The user starts ...
|
|
Reynolds high-speed permanent magnet synchronous motor dedicated driver
The state proposes to "peak carbon emissions" by 2030 and complete "carbon neutrality" by 2060. Carbon neutrality is to try to reduce carbon dioxide emissions, and eventually achieve net zero emissions, that is, to make carbon dioxide emissions even offset.
However, due to economic development, CO2 emissions are stable ...
|
|
Reynolds inverter control panel and code function description
1. Clarification of the function of the control panel
1. FUN button; Press the FUN button to enter the settings menu F00;
2. Press and hold the up or down button to scroll to the code you need to set;
3. At this moment, press the FUN button to confirm, and adjust the entry parameters to the required value;
4. After the adjustment is completed, ...
|
|
Difference Between Soft Starter and Inverter – Reynolds
Soft starters and frequency converters are two completely different products. The inverter is used in the local area where speed regulation is required, and its output not only changes the voltage but also changes the frequency at the same time; A soft starter is actually a voltage regulator, which is used when starting a motor, and the output only changes the voltage and does not change the frequency. Change...
|
|
Structural characteristics of Reynolds RHY series inverter governor
1. Advanced technology: (PC or PLC) is used to make the equipment complete the intelligent constant pressure variable supply water supply according to the requirements of water supply and fire protection;
2. High efficiency and energy saving: the system can set the pressure according to the demand, and the system can actively adjust according to the set pressure.
|
|
Frequency conversion cabinet external conduit wiring method - Reynolds
When it is required to wiring outside the frequency conversion cabinet, it is generally necessary to use the conduit for wiring, which requires suitable mechanical pressure and unsuitable mechanical damage, moisture-proof and corrosion-resistant. Conduits include the following two wiring methods:
1. Kim ...
|
|
Dust design considerations for frequency converters - Reynolds frequency converters
1) The air duct of the inverter cabinet should be planned reasonably, and the exhaust should be clear and smooth, so as to avoid the formation of vortex in the cabinet and the accumulation of dust in a fixed direction.
2) The top air outlet of the inverter cabinet should be equipped with a protective top cover to avoid debris from falling directly.
|
|
Reynolds-5G empowers the paper industry to improve quality and efficiency of the industrial IoT control system
From September 23rd to September 25th, 2020, the 2020 China International Paper Technology Exhibition was held in Hall D1 of Suzhou International Expo Center.
|
|
Inverter power and box structure selection - Reynolds
First, the selection of inverter power
The system power is equal to the product of the inverter power and the motor power, and the system power is higher only when both are operating at a higher power. From the perspective of power, when selecting the power of the inverter, we should pay attention to the following points:
1) ...
|
|
The abnormal installation of the inverter in the power frequency motor leads to hazards
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the precise control and speed regulation of the motor, and improve the power and accuracy of the progressive motor. However, if it is not properly used and used, the following damages may occur:
...
|
|
The water pump is controlled by a frequency converter – Reynolds
1. The constant pressure water supply of the inverter increases the comfort of water supply by 3 times
2. Constant water pressure, reducing pipe bursts and leakage by 80%
3. High efficiency and energy saving, power saving effect up to 20%-60% (depending on the actual situation)
4. The use of frequency converters can realize multi-point pressure in different time periods.
|
|
Misunderstanding of inverter selection - Reynolds
1. In order to save power, the inverter is selected
Many manufacturers and salesmen praise how high the power-saving rate of the inverter is, and the user also believes that it is true, and the inverter is selected at a high cost simply in order to save electricity, but the results are greatly disappointed.
Whether the inverter can save power after using it is determined by the load driven by it.
|
|
Progressive method of robustness of automatic control cabinets – Reynolds
1. Appropriate working environment
1. The ambient temperature is suitable
All manufacturers have certain rules for active temperature control cabinets. The PLC promises that the ambient temperature is usually about 0 to 55 ° C, so during the equipment process, this heating element is not placed in the PLC; The PLC should have adequate ventilation and ...
|
|
How to deal with the inlet water of the inverter - Reynolds
Inverters are widely used in all walks of life, in a variety of applications, inverters will inevitably encounter rainy and humid climate, resulting in internal wetness, or accidentally into the water, in fact, as long as it is found in time, it can still be rescued.
If it is in the unpowered state ...
|
|
Reynolds inverter code function description
F09 second acceleration time 0.10 - 999.9sec; 5.0sec; △ The first acceleration and deceleration parameters and the second acceleration and deceleration parameters are switched by terminal X3 (see F55);
F10 second deceleration time 0.10 - 999.9sec; 5.0sec; △ The first acceleration and deceleration parameters and the second acceleration and deceleration parameters ...
|
|
Introduction to the key components of the inverter - Reynolds
There are many kinds of components of the inverter, different components have different functions, and different components have different specializations! In addition to the composition and application of Aideley inverter, there are also key components of inverter to provide for the operation of inverter.
|
|
The difference between servo and inverter - Reynolds
Overload can be different
Servo drives generally have 3 times the overload ability, which can be used to overcome the inertial moment of the inertial load at the moment of start-up, while the frequency converter generally allows 1.5 times the overload.
Handling precision