Schneider intermediate relays
Schneider 24VDC intermediate relays are the most common components in control systems. Generally, 2 normally open and 2 normally closed are the most commonly used, but sometimes 4 normally open and 4 normally closed contacts are not enough. Both have different coil and base models.
...
|
|
The difference between the highest frequency and the basic frequency of the inverter - Schneider
1. There are two ways to say the fundamental frequency:
(1) The frequency corresponding to the maximum output voltage of the inverter is called the fundamental frequency;
(2) When the output voltage of the inverter is equal to the additional voltage, the minimum output frequency is called the fundamental frequency. The fundamental frequency is expressed in fBA.
...
|
|
Schneider considers the safety of lithium batteries from four perspectives
In China, the trend of UPS switching to lithium batteries will become more and more rapid. As a global leader in data center infrastructure solutions and services, Schneider Electric found that in addition to the purchase price factor, Chinese customers are now choosing the weight of UPS lithium batteries after accurate positioning and inquiry of shopping malls.
|
|
There is a remote code execution vulnerability in Schneider industrial equipment
Recently, Armis security researchers have reported that Schneider Electric's programmable logic manipulators (PLCs) have serious and unpatched gaps in long-distance code fulfillment, allowing intruders to manipulate their various industrial systems.
Schneider ...
|
|
Inverter trip protection circuit – Schneider
After the maintenance function of the inverter is caused by the operation of the problem, it will trip immediately, and the fault code will be displayed together, and the tripping alarm indication circuit of the peripheral inverter will send out an audible and visual alarm to remind the operator to clean up the problem in time.
Inverter hopping ...
|
|
Advantages of the Schneider Magelis GXU touchscreen
1. Save capital contribution
Focus on central function (true color LCD, serial communication interface, USB connection, Ethernet interface, etc.)
2. Save space
Compact structure planning, only 38mm thick
The fuselage is reserved for communication wiring ...
|
|
Measures to reduce the interference of Schneider inverters themselves
(1) Add inductance and capacitance on the input side of Schneider inverter to form an LC filtering network
(2) The power cord of the Schneider inverter is supplied directly from the transformer side.
(3) If conditions permit, a separate ...
|
|
Technical causes of Schneider low-voltage circuit breaker accidents
(1) Operational failure
Operation failure is manifested by the dragging or misoperation of the circuit breaker. Because the fundamental and important function of the high-voltage circuit breaker is to act correctly and quickly remove the fault of the power grid. If the circuit breaker is dragged or misoperated, it will pose a serious threat to the power grid, first of all: (1) expansion ...
|
|
Precautions for the use of Schneider AC contactors
There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A
When installing, it should be in accordance with the regulations...
|
|
Schneider Category VI unshielded RJ45 information module
Product Introduction
compose
1. RJ45 module body, 8 IDC contact pins
2. Crimping module
3. Back cover 7751S (optional)
Operating temperature range
-40°C to +70°C (65°C for non-stop use)
...
|
|
Schneider inverter enters the parameter setting method
1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct
2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification
3. Next, set the function parameters to launch the ...
|
|
The energy-saving effect of using frequency converter for fan and pump loads
Why is the use of inverter for fan and pump loads to save energy?
According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...
|
|
Schneider electrical circuit control fault range
In general, depending on the phenomenon of equipment problems, the scope of the problem can be roughly confirmed as follows:
1) All button functions fail, and there is a high possibility of power supply or fuse problems.
2) Some buttons are invalid, and some of the buttons are functioning normally ...
|
|
Selection and control of the inverter installation - Schneider
Frequency converters are widely used equipment in modern industry. If you want to complete the functions of soft stop, soft start, stepless speed regulation or special requirements for speed rise and fall, you need the more advanced speed control equipment in modern asynchronous motors - frequency converters. The main circuit of the equipment is selected to communicate - DC - communication ...
|
|
Is there a restriction on the installation direction when Schneider installs the inverter?
It should be basically stored in the plate, the problem is that the plate with a fully enclosed structure is large in size, takes up a lot of space, and the cost is higher. This can be done by:
(1) The planning of the disc should be based on the heat dissipation required by the actual device;
(2) Profit ...
|
|
Schneider instrumentation maintenance precautions
1. When installing and adjusting the appearance, the original status should be recorded for rehabilitation.
2. When repairing the appearance of fine instruments, if you accidentally bounce small parts away, you should first determine the direction where you can fly.
|
|
The control mode of low-voltage inverter - Schneider
From the perspective of skills alone, the control method of the low-voltage inverter also indicates its skill portal to a certain extent. Here, we've broken down the following manipulation methods:
1. Sinusoidal pulse width modulation
Sinusoidal Pulse Width Modulation (SPWM) is characterized by the simple structure of the control circuit, the cost of ...
|
|
Schneider instrumentation winter insulation measures
The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on.
Selection method
Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...
|
|
Schneider inverter Eplan file download
Product line:
Frequency converters and soft starters
Solution(s):
All Eplan software users can visit the Eplan website (directly from the Eplan software). The EPLAN database includes ...
|
|
Schneider circuit breaker maintenance
1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences:
(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the action of the arc, and the insulation between the fractures after the main contact is broken is destroyed.
|