Schneider instrumentation maintenance precautions

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

1、安装、调节外表时,应记实本来的地位,以便康复。

  2、修补精细仪器外表时,如不慎将小零件弹飞,应首先断定可以飞落的方位,切勿东找一下,西翻一下,可采纳磁铁扫描和视野扫描方法实施找寻。

  3、检验时不用自觉乱敲乱碰,以防扩展缺点,越修越坏。

                            Schneider instrumentation maintenance precautions

  4、不用带电插拔各类控制板和插头。

  5、检验外表外部电路时,假设装置元件的接点和电路板上涂了绝缘清漆,测量各点参数时可用普通手缝针焊在万用表的表笔上,以便刺穿漆层直接测量各点,而不用大面积剥离漆层。

  6、在湿润环境下检验外表缺点时,对印刷线路用万用表测其各点能否迟滞很有必要,由于这种情况下的重要缺点是铜箔腐蚀。

  7、检测电源中的滤波电容时,应先将电解电容器的正负极短路一下,而且短路时不用用表笔线来代替导线对电容器实施放电,由于这样随意烧断芯线。可以取一只带灯头引线的220V,60——100W的灯,接于电容器的两头,在放电霎时灯泡会闪光。

  8、运用逻辑笔、示波器检测信号时,要留心不使探针一起接触两个测量引脚,由于这种情况的本质是在加电的情况下构成短路。

More on that
Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker

Circuit breaker action time test. The closing and opening control lines of the circuit breaker mechanical characteristics tester are respectively connected to the secondary control line of the circuit breaker, and the lead wires of each break of the circuit breaker are connected to the mechanical characteristics of the circuit breaker with the test wiring.

There is no indication on the UPS boot panel that UPS is not working - Schneider There is no indication on the UPS boot panel that UPS is not working - Schneider

Fault analysis: judging from the fault phenomenon, the fault is in the mains input, battery and mains detection part and battery voltage detection loop: 1. Check whether the mains input wire is incinerated; 2. If the mains input is stable...

Diode selection and substitution method - Schneider Diode selection and substitution method - Schneider

1. Selection of detection diode Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Despite the ...

Precautions for the use of Schneider AC contactors Precautions for the use of Schneider AC contactors

There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A When installing, it should be in accordance with the regulations...

Schneider inverter maintenance power settings, waveform test problems Schneider inverter maintenance power settings, waveform test problems

1. After the inverter is repaired, the power number needs to be modified, don't forget it Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...

Advantages of Schneider molded case circuit breaker Advantages of Schneider molded case circuit breaker

The contact orientation is 100% secure As for the circuit breaker, the indication of the handle can also be said to be the fault indicator of the circuit breaker, if it is "blurred" for a while, it may cause irreparable damage. Therefore, according to the requirements of the national standard, in any case, the hand of the circuit breaker ...

How to prevent counterfeiting from Schneider switch sockets How to prevent counterfeiting from Schneider switch sockets

1. Logo The logo of the product is a status symbol, so it will be made very exquisitely. Schneider switches are also very careful in the production of logo, each letter is like an independent work of art, and let's see that the letter "A" is flat and wide. But the imitation ...

Functions of input/output pins P0, P1, P2, P3 – Schneider Functions of input/output pins P0, P1, P2, P3 – Schneider

P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...

Rebecca · Lowell · Edwards Schneider Electric's first Global Head of Communications Rebecca · Lowell · Edwards Schneider Electric's first Global Head of Communications

GENEVA – Rebecca Lowell Edwards, who has been with the International Olympic Committee for the past 18 months·· has joined Schneider Electric as the company's first global communications chief. In the new work that starts today, love ...

Schneider instruments measure error factors Schneider instruments measure error factors

When measuring, because various elements will constitute a small number of errors, these elements need to be understood and effectively solved, so that the errors in the whole measurement process can be reduced to the smallest. When measuring, the main errors that constitute errors are system errors and random errors, and system errors have the following conditions: misreading, ...

Schneider inverter series at a glance Schneider inverter series at a glance

1. ATV11 series The Schneider ATV11 series is primarily used in three-phase asynchronous motor inverters with a power range of 0.18 to 2.2 kW. 2. ATV12 series ATV12 Schneider inverter for power scale 0.18k...

Pay attention to the problem when using UPS power supply - Schneider Pay attention to the problem when using UPS power supply - Schneider

1. The parameters set in the host cannot be changed at will during use. In particular, the parameters of the battery pack will directly affect the service life. With the change of ambient temperature, the float charge voltage should be adjusted accordingly. Generally, 25 °C is the standard, and when the ambient temperature rises or falls by 1 °C, the float charge ...

Methods to reduce the interference of Schneider inverters themselves Methods to reduce the interference of Schneider inverters themselves

When there are high-frequency impact loads such as welding machines, electroplating power supplies, electrolytic power supplies, or slip ring power supply near the power supply system of Schneider inverter, the inverter itself is simply protected due to interference. It is recommended that users choose the following methods: ...

Schneider circuit breaker technical issues Schneider circuit breaker technical issues

1. Overload maintenance failure: The circuit breaker should be tripped for maintenance when the current exceeds the rated current, but sometimes the overload maintenance failure may be due to some reasons. This may be due to incorrect overload maintenance settings, long overload periods, thermal aging due to successive overloads, etc. 2 ...

Schneider ATS48 soft starter issue Schneider ATS48 soft starter issue

1. What type of ATS48 power supply is? The control power supply of ATS48 selects communication input, and supplies power to the controller, input and output ports through internal power processing; The control power supply of Q series products is 220V-415V; Handling of the Y-Series ...

Schneider servo motor advantages Schneider servo motor advantages

Schneider servo motor is one of the brands of servo motor, the performance is relatively good, is a brand made in Germany, in China ** degree is relatively high. Servo motor refers to the servo system, (servomechanism) in which the mechanical components are controlled.

Precautions for the selection of Schneider foot switches Precautions for the selection of Schneider foot switches

The foot switch series is XPE, and it should be noted when selecting: 1) Raw materials: metal and plastic, which are used in heavy-duty, high-risk, light-duty, low-risk occasions. 2) Pedal: divided into single pedal and double pedal (type end plus D). 3) With or without maintenance cover ...

Analysis of common problems of Schneider inverter Analysis of common problems of Schneider inverter

1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA? Because the maximum output frequency parameter of the inverter is "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...

Analysis of 10 reasons for frequent tripping of Schneider leakage switches Analysis of 10 reasons for frequent tripping of Schneider leakage switches

1. Defective device If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action. 2. Leakage switch with ...

The operation essentials of Schneider disconnectors The operation essentials of Schneider disconnectors

Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it is able to disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. Secondly, the Schneider barrier switch can be used with the circuit breaker to change the operation of the system.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top