In the design of the power converter, firstly, the circuit topology is determined according to the load requirements, the composition and backup mode of the power converter are determined, the main parameters of the power converter are input voltage range, output voltage accuracy, load stability, voltage stability, output ripple, efficiency and dynamic indicators, in order to achieve the purpose of protecting the load and the power converter, the power converter has overcurrent protection overvoltage protection and undervoltage protection capabilities, and after the fault is revoked, the power converter can resume normal operation, The power converter responds quickly to changes in bus voltage and load. Therefore, the dynamic characteristics of the power converter (start-up characteristics, input voltage step characteristics, load step transient characteristics) are also important characteristics of the power converter. In addition, in order to meet the requirements of the space environment, the power converter needs to consider the space radiation resistance, reliability index and design life index, which are mainly related to the circuit topology, thermal design, component quality level and component parameter derating.

On the basis of the analysis task requirements, the selection of suitable circuit forms, especially the power stage circuit, should strive to be simple and reliable, give priority to the single-ended circuit topology, choose the mature circuit and standard circuit that have been tested by flight, and also have good fault isolation measures at the input end and the adaptability of the output to the load fault. The selection of circuits is closely related to the selection of components, especially some discrete components, such as power tubes, rectifier diodes, filter capacitors, etc., should be preferred to fly proven high-reliability products and derated.

In the electromagnetic compatibility design of the power converter, an EMI filter is added at the input end to reduce the influence of the input reflected ripple voltage on the spacecraft power supply system, and a filter circuit is added at the output end to reduce the impact of output ripple and noise on the electrical equipment, and the oscillation frequency of the pulse width modulator of the power converter should be selected after coordinating with the working frequency of the load equipment as far as possible. The wiring, isolation, and grounding inside the power converter should be designed based on the principle of electromagnetic compatibility of the electrical system.
RKC converter – the design essentials of the power converter

More on that
Common faults and solutions of RKC temperature controllers Common faults and solutions of RKC temperature controllers

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done. 2. Temperature controller ...

How to set the parameters of the RKC rs400 thermostat? How to set the parameters of the RKC rs400 thermostat?

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key data will change rapidly, press the SET key again ...

RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules

1. Under what circumstances should I use a thermostat to expand the module? The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches. For example, a large area ...

RKC Level Gauge – Precautions for the installation of float level gauges RKC Level Gauge – Precautions for the installation of float level gauges

1. The specific gravity of the liquid to be measured must be greater than the specific gravity of the float 2. The measured medium should not contain ferromagnetic impurities 3. The float level gauge should be installed in an unobstructed position when the float moves up and down 4. Magnets are not allowed to be close around the float level gauge, otherwise it will affect the float.

The debugging method of the temperature controller The debugging method of the temperature controller

Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm. 1. Turn on the smart thermostat ...

RKC thermostat Digital display controller parameter setting method RKC thermostat Digital display controller parameter setting method

A digital display controller is a simple controller with indication, control, remote transmission and alarm functions. As a secondary instrument commonly used in sensors, it is very important to operate and use it correctly. Applications such as level control, temperature control, pressure control and parameter value display of measured variables. ...

How to set the parameters of the RCRS400 thermostat How to set the parameters of the RCRS400 thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again ...

RK Level Gauge - Four common types of faults and solutions for float level gauges RK Level Gauge - Four common types of faults and solutions for float level gauges

1. The indicated value is large (or out of range). According to the investigation of our staff, this kind of problem often appears in the atmospheric pressure workshop. When we find that the counterweight of the float in the float level gauge is at a low point, the liquid level must be very high at this time, and the glass plate is inconsistent with the indication of the instrument.

RK thermostat - the use and adjustment of temperature control instruments RK thermostat - the use and adjustment of temperature control instruments

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to add the set value, press the v key to decrease the setting value, press and hold the △ key or √ key The data will change rapidly, press the SET key again ...

What should I pay attention to when operating the RKC thermostat? What should I pay attention to when operating the RKC thermostat?

The instrument can be cleaned only after the power is off; To remove stains from the monitor, use a soft cloth or cotton paper; The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the keys will be damaged or scratched. ...

RK Thermostat - 5 Common Faults of Thermostat and Solutions RK Thermostat - 5 Common Faults of Thermostat and Solutions

1. After heating for a period of time, it is found that the temperature has not changed, and the temperature has been displayed at the time of the ambient temperature. In this case, you need to check that the SV value setting value is set, whether the OUT value indicator of the meter is not lit, and whether the No. 3 and 4 segments of the universal meter are 12VD ...

RKC thermostat - introduction of the three output modes of the thermostat RKC thermostat - introduction of the three output modes of the thermostat

The first output method is relay output, which is output for temperature control through the switching signal of the relay on/off, which is used to directly control the load less than 5A, or directly control the contactor and the intermediate relay, and control the high-power load externally through the contactor. The second ...

Specifications and models of RLC thermostats Specifications and models of RLC thermostats

CH102 (48×48×100mm) CH402 (48×96×100mm) CH902 (96×96×100mm) 1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L ...

RK Level Gauge - Introduction to the characteristics of float level gauge RK Level Gauge - Introduction to the characteristics of float level gauge

It is suitable for measuring the level and interface of the liquid medium in the container. In addition to on-site instructions, it can also be equipped with remote transmitters, alarm switches, and detection functions. The indication is novel, the reading is intuitive, eye-catching, and the direction of the observation indicator can be changed according to the user's needs. Large measuring range ...

How the thermostat works – RKC How the thermostat works – RKC

Thermostat, according to the temperature change of the working environment, physical deformation occurs inside the switch, so as to produce some special effects, a series of automatic control elements that produce on-on or off-action actions, or different principles of electronic components at different temperatures and working states to give ...

RKC thermostat operation attention and its main features RKC thermostat operation attention and its main features

RKC thermostat operation attention · Clean the instrument only after the power is off; · Please use a soft cloth or cotton paper to remove stains on the monitor; · The display is easy to be scratched, it is forbidden to use hard object to operate the panel buttons, otherwise the keys will be damaged or scratched.   Key features: ...

RLC Thermostat - Overview and characteristics of mechanical thermostats RLC Thermostat - Overview and characteristics of mechanical thermostats

Mechanical thermostats are suitable for indoor temperature control in industrial, commercial and residential buildings. The mechanical thermostat uses an inflatable diaphragm box to sense the temperature and compare it with the user's set temperature to automatically control the air conditioning equipment to achieve the purpose of indoor constant temperature. For commercial, industrial and civil construction, available ...

RKC Level Gauge – How to install a buoy level gauge RKC Level Gauge – How to install a buoy level gauge

1. Welding and installation of the lower support of the guide wire: determine the position at the bottom of the container according to the requirements of the movement direction of the float of the level gauge, and weld or rivet the lower support of the fixed guide wire. If the equipment does not have welding conditions, the heavy anchor fixing method can be used to fix the guide wire under the support. For example, the liquid level wave in the container ...

Difference Between Thermocouple and RTD Difference Between Thermocouple and RTD

In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different. This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.

RRKC thermostats – about output and control performance RRKC thermostats – about output and control performance

When using a temperature controller to control a heater, it is necessary to convert the control calculation results of the temperature controller into electricity and apply it to the heater. Electromagnetic relays, solid state relays or phase controllers are usually used for conversion. Depending on the conversion method, the output of the temperature controller is different ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top