RKC Level Gauge – Precautions for the installation of float level gauges

Create Date: 2024-8-30 12:03:23|Source: RKC

1. The specific gravity of the liquid to be measured must be greater than the specific gravity of the float

2. The measured medium should not contain ferromagnetic impurities

3. The float level gauge should be installed in an unobstructed position when the float moves up and down

4. Magnets are not allowed to be close around the float level gauge, otherwise it will affect the normal operation of the float level gauge

5. The installation position of the float level gauge should be far away from the feed port, otherwise it will cause malfunction due to the fluctuation of the feed port
RKC Level Gauge – Precautions for the installation of float level gauges

More on that
RLC Thermostat – The reason why the temperature control meter shows HHH RLC Thermostat – The reason why the temperature control meter shows HHH

The reasons why the temperature control table shows HHH are as follows: 1. The thermocouple signal line is reversed, or short. 2. If the temperature control meter is in normal use before, it is recommended to check whether the signal line of the thermocouple is broken. 3. The wire inside the thermocouple is broken. 4 ...

RRKC thermostat - five common faults and solutions of smart thermostats RRKC thermostat - five common faults and solutions of smart thermostats

After heating for a while, the temperature does not change. Displays the ambient temperature of the site at all times (e.g. room temperature 25°C) In case of such a fault, first check whether the SV value setting value is set, whether the OUT indicator of the meter is lit, and whether the No. 3 and No. 4 terminals of the meter are 12VDC output with the "multimeter". ...

Common faults and failure analysis of RTC thermostats Common faults and failure analysis of RTC thermostats

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which leads to the breakpoint of the solder joint, and sometimes it is caused by the phenomenon of virtual soldering at the factory, and the main re-soldering can be done. 2. Temperature controller ...

RK Thermostat - The working principle and device precautions of liquid expansion thermostat RK Thermostat - The working principle and device precautions of liquid expansion thermostat

How liquid expansion thermostats work Liquid expansion thermostat is a physical phenomenon (volume change) that causes the material (generally liquid) in the temperature sensing part of the thermostat to undergo corresponding thermal expansion and cold contraction when the temperature of the controlled object changes, and the diaphragm box connected with the temperature sensing part expands or ...

RLC Thermostat – Precautions for Thermostat Operation RLC Thermostat – Precautions for Thermostat Operation

1) Measure the function Its temperature measurement scale is mainly between -20 °C and 80 °C, and the humidity measurement scale is mainly between 20% RH and 99% RH. In addition, it has a temperature resolution of 1°C and a humidity of 1%RH. 2) Parameters and data display functions Temperature and humidity control ...

RKC Level Gauge – The correct maintenance method for float level gauges RKC Level Gauge – The correct maintenance method for float level gauges

(1) After 6 months to 1 year of operation, the sensor should be visually inspected and routinely calibrated. (2) Regularly check whether the sensor is bent and deformed by external force to avoid ball jamming. (3) Regularly check whether the magnetic induction switch element of the sensor is aging and failing, ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

RRC thermostat - introduction to the working principle and classification of electronic thermostats RRC thermostat - introduction to the working principle and classification of electronic thermostats

Principle of electronic thermostat: The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, which has its own advantages and disadvantages. Household Air Conditioner Temperature Controller ...

RKG thermostat - an introduction to the characteristics of digital displays RKG thermostat - an introduction to the characteristics of digital displays

1) It is a display of the common cathode. It uses the principle of the positive electrode as the segmented input, with the ground wire as the common output, and the segmented input is valid as a high-level input. 2) It is a display with a common anode. It uses an anode as an aggregate input, and in contrast to the common cathode, the segment is effective at a low level output ...

RK Level Gauge - Four common types of faults and solutions for float level gauges RK Level Gauge - Four common types of faults and solutions for float level gauges

1. The indicated value is large (or out of range). According to the investigation of our staff, this kind of problem often appears in the atmospheric pressure workshop. When we find that the counterweight of the float in the float level gauge is at a low point, the liquid level must be very high at this time, and the glass plate is inconsistent with the indication of the instrument.

RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller RLC Thermostat - Fault and Troubleshooting of Vapor Pressure Temperature Controller

Faulting and troubleshooting of vapor pressure temperature controllers (1) Common faults and common faults of the vapor pressure type temperature controller include contact burning or adhesion, failure of the mechanical transmission mechanism and leakage of temperature sensor in the temperature sensing tube. Its detection method is: put the thermostat knob in a parking position, and use ...

Analysis of common fault causes of RKC temperature controller Analysis of common fault causes of RKC temperature controller

1. The power indication is normal, but the temperature controller has no screen display. Most of this fault is caused by the heating of the voltage regulator element (7805 or 7812) on the thermostat during long-term use, which causes the solder joint to show a breakpoint, and sometimes it is caused by the phenomenon of virtual soldering at the factory. 2. Temperature controller ...

RRKC Thermostat – The working principle and main features of the pop-up thermostat RRKC Thermostat – The working principle and main features of the pop-up thermostat

How it works The sudden jump thermostat is a kind of bimetal disc after constant temperature as a heat-sensitive reaction component, when the temperature of the main part of the product increases or decreases, the heat generated is transferred to the bimetal disc, and when the operating temperature is set, it acts quickly, and the contact is broken through the action of the mechanism.

RKC Thermostat – What are the common faults of thermostats? RKC Thermostat – What are the common faults of thermostats?

1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself. 2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...

RLC thermostats – the classification of thermostats and their detailed introduction RLC thermostats – the classification of thermostats and their detailed introduction

1. Sudden jump thermostat The type of various sudden thermostats is collectively called KSD, such as KSD301, KSD302, etc., the thermostat is a new type of bimetal thermostat, mainly as a variety of electric heating products with overheat protection, generally connected with the thermal fuse in series, sudden temperature ...

rkc thermostat – five advantages of thermostat over PLC rkc thermostat – five advantages of thermostat over PLC

Programmable logic controllers (PLCs) and temperature controllers (thermostats) offer similar benefits in ensuring effective process control, achieving consistent quality, and minimizing user error in manufacturing. Since the 17th century, process control equipment has been used in a variety of forms.

RRKC Thermostat – The solution to the failure of the jump thermostat switch RRKC Thermostat – The solution to the failure of the jump thermostat switch

1. The cleanliness and finish of the contact surface have a great impact on the working state of the contact. When the appearance of the contact is rough or there is residue on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate the residues; Add the process of residue selection, ...

RKC Level Gauge – the correct way to use the float level gauge RKC Level Gauge – the correct way to use the float level gauge

(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified. (2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements. (3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.

RLC thermostat - introduction to the performance characteristics of intelligent digital display controller RLC thermostat - introduction to the performance characteristics of intelligent digital display controller

1. The special integrated instrument chip has more reliable anti-interference and stability. 2. Signal input, which can be matched with commonly used thermal signals through menu settings. 3. The display range, transmission output range, alarm value and alarm mode can be modified online. 4. Soft ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

CH102 (48×48×100mm) CH402 (48×96×100mm) CH902 (96×96×100mm) 1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top