How to set the parameters of the RKC rs400 thermostat?

Create Date: 2024-8-30 12:03:23|Source: RKC

1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ button or ▽ key The data will change rapidly, press the SET key again and the appearance returns to the normal operating condition and the temperature is set.

2. Return control (XMT201-C): Press the SET button for 3 seconds to enter the inner layer parameter setting status. The first presented and flashing parameter is C00, that is, the return difference control parameter should be adjusted steadily, the appearance of the control heating output value to the set value, when the temperature falls to the set value to reduce the difference value, and then start heating, the output (relay) is not active within the return scale, so that the relay action times can be reduced to extend the relay life. For example, if the setting value is 80.0°C and the return difference is 0.5, the relay is released when the surface control is heated to 80.0°C, and the relay is engaged again when the temperature drops to 80.0°C-0.5°C=79.5°C. The larger the return difference, the fewer the relay actions, and the excessive return difference will reduce the control accuracy. After adjusting the differential parameters, press the SET button for 3 seconds to return to the normal operating condition.

3. Early Setting (XMT201-E): Press the SET button for 3 seconds to enter the inner layer parameter setting. The first parameter that is presented and flashed is E00, that is, the early amount of heating stopped, and the early amount parameter should be adjusted steadily, in order to reduce the temperature overshoot, the heating will be cut off early when the heating output is controlled on the surface. When the temperature drops below the early amount, the heat is started, and the output (relay) is not operated within the set value and the early amount, so that the number of relay actions can be reduced to extend the life of the relay. For example, if the setting value is 50.0°C and the early amount is 0.5, the relay will be released when the surface control is heated to 49.5.0°C, and the relay will be engaged again when the temperature drops to 50.0°C-0.5°C=49.5°C. The larger the early amount, the fewer the relay actions, and the excessive early amount will reduce the control accuracy. After adjusting the early amount parameters, press the SET button for 3 seconds to return to the normal operation status

4. Time share setting (XMT201-P): Press the SET button for 3 seconds to enter the inner layer parameter setting status. E: is the share band offset, and the E parameter allows the practice control point to be translated. Even if the center of the moment share shifts, the E value can be positive or negative depending on the heating system. P: is the share band, that is, the share manipulation value, in order to facilitate understanding and also to make the share with a larger representation space, the share band in this table is a unilateral share band, that is, the practical share band is 2 times the P value. Focusing on the practice control point, from bottom to top, the output heating share is evenly distributed from 0% to 100% within the scale of P value. T: For the heating output cycle cycle, that is, the relay operation cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent operation. Generally, the T value is taken for 20-60 seconds. For example, if P is set to 4.0 (the actual share band is 8.0), the temperature is set to 60.0 degrees, and E is set to 2.0 degrees, then the practice control point is 58.0 degrees, and when the temperature reaches 54.0 degrees, the appearance will enter the share band control state.

5. Intelligent control parameter setting (XMT201-D): Press the SET button for 3 seconds to enter the inner parameter setting status on the outer surface. E: This parameter is the early amount of heating stop when P = 0, when P is not equal to 0, the appearance is intelligent PID operation mode, and when P is not equal to 0, E parameter is meaningless. P: is the share band, that is, the share control value, the P-value is scattered on both sides of the set point with the set value as the center of the external table, and the PID mode is used in the inner and outer tables of the P value scale. T: For the heating output cycle cycle, that is, the relay operation cycle cycle, the T value is small and the control effect is good, but the T value is too small The relay will reduce the life due to frequent operation. Generally, the T value is taken for 20-60 seconds. To simplify the operation, the integration time (I) and the differential moment (D) of the appearance are designed as hidden parameters, and their default values: I=180, D=45

6. Correction of errors: Correction of the apparent value can be made when it is admitted that the apparent value is not the correct measured value. Press the SET button for 3 seconds to enter the inner menu on the surface, the first parameter presented and flashed is E00, that is, the early amount, and then press the SET key again to present and flash the parameter that is the error correction parameter, and this parameter can be modified by the cooperation △ or ▽ key. The scale of the error correction is -9.9°C to +9.9°C, and after the correction is completed, press the SET button to exit. The correction value of the appearance is 0.0 when leaving the factory, and it is necessary to avoid correcting the correct appearance to incorrect when using.
How to set the parameters of the RKC rs400 thermostat?




More on that
RKC Level Gauges – How to Install Float Level Gauges Correctly RKC Level Gauges – How to Install Float Level Gauges Correctly

In general, the following points should be followed when installing a float level timer: 1. In order to prevent the float from sliding or hitting the sealed tube at high speed during transportation, causing the measuring belt to fall out, the instrument is fixed at the bottom of the sealed tube with a clamp before leaving the factory, and the magnet is on the top of the sealed tube.

RRC thermostat - how to adjust the smart thermostat RRC thermostat - how to adjust the smart thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, long press the △ key or ▽ key The data will change rapidly, press the SET key again ...

RKC level gauge - buoy level gauge structure composition RKC level gauge - buoy level gauge structure composition

The level gauge is composed of five parts: float, traction cable, guide pulley, hammer pointer, display ruler or magnetic flap. 1. Float: The float is welded with two stainless steel (or carbon steel) fasting cones and one stainless steel (or carbon steel) fasting cylinder.

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for the first output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, Finally, the three pins are connected to thermocouples or PT100 ...

RKC thermostat - what are the anti-interference measures of the instrument? RKC thermostat - what are the anti-interference measures of the instrument?

1. Electromagnetic induction (refers to the coupling of magnetism). There is a strong alternating magnetic field in the surrounding space of high-power transformers, AC motors, high-current power grids, etc., and the closed loop formed by the lines of the control system (detection, transmission, conversion, regulation, calculation, execution, auxiliary, display, etc.) is located in the ...

Common faults in the use of RKC thermostat Pt100 RTD Common faults in the use of RKC thermostat Pt100 RTD

  PT100 RTD is a platinum RTD, which can be regarded as a more commonly used thermometer in the range of medium and low temperatures, and it has a wide range of uses, including medical, electric, industrial production, thermometers and other high-precision thermometers. But due to the range of use ...

RKC Level Gauge – Installation of a pontoon level gauge RKC Level Gauge – Installation of a pontoon level gauge

When transporting and unpacking, it is necessary to avoid excessive shock and vibration; The installation should be firm and reliable, and the pontoon should be installed vertically to prevent the pontoon from colliding with the interior wall of the pontoon; When the pontoon is hooked, it should not swing or pull and compress sharply, so as not to damage the sensor and reduce the accuracy of the instrument; ...

Introduction to the types of alarms for RRKC thermostats Introduction to the types of alarms for RRKC thermostats

* Alarm table {ALM1} (standard built-in) A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached B: Lower limit deviation alarm H: Upper limit input value alarm C: Upper and lower limit deviation alarm J: Lower limit input value alarm D: Alarm in the range K: Attached standby ...

Wiring method of the RKG thermostat Wiring method of the RKG thermostat

Take CD901 as an example, L(1) pin to 220 volt live wire, N(2) pin 220 volt neutral wire, 3,4 pins for *** output, 5,6 pins for the second output, 7, 8, 9 pins are alarm output, The rear three pins are connected to thermocouples or PT100 and so on.

RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad? RRC thermostat - the principle of sudden jump thermostat, how to judge the good or bad?

1. What is the principle of the sudden jump thermostat? The sudden jump thermostat is a kind of thermostat, which is a series of automatic control elements that are physically deformed inside the switch according to the temperature change of the working environment, resulting in some special effects and on-off action. Sudden jump ...

How to set the parameters of the RKC fb900 thermostat How to set the parameters of the RKC fb900 thermostat

Model definition FB90②③*④4⑤⑥⑦⑧⑨-0( CODE 8N-4*4NN5/A1-F801/Y control "(1)(2)" indicates Output 1 and Output 2 classes M: Relay output V: Voltage pulse output 5: 0-10V 8: 4-20mAN: No output “ ...

RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules RRKC Thermostat – Questions and Precautions About Thermostat Expansion Modules

1. Under what circumstances should I use a thermostat to expand the module? The gradual development of the heating field is now very well recognized, and more and more users have begun to install electric heating, of course, when installing electric heating for users, they have also encountered some headaches. For example, a large area ...

Specifications and models of RKC thermostats Specifications and models of RKC thermostats

1. RH400 size: 48*96, depth 60, about 250g 1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L 2. Temperature measurement heat resistance input: PT100, JPT100 3. Tributary voltage: DC0 - DC5V, DC1 - DC5V ...

RKG thermostat - an introduction to the characteristics of digital displays RKG thermostat - an introduction to the characteristics of digital displays

1) It is a display of the common cathode. It uses the principle of the positive electrode as the segmented input, with the ground wire as the common output, and the segmented input is valid as a high-level input. 2) It is a display with a common anode. It uses an anode as an aggregate input, and in contrast to the common cathode, the segment is effective at a low level output ...

RHK thermostat - common faults and maintenance methods of thermostats RHK thermostat - common faults and maintenance methods of thermostats

1. Thermostat contact contact failure Poor contact of the thermostat contacts will cause the compressor to not operate properly. If the contacts are sticky, the compressor will fail without downtime. For this, you can use a small screwdriver to open the metal shell of the thermostat, and then use a fine abrasive cloth to polish the surface of the contacts ...

RKC thermostat - how to set the parameters of the thermostat? RKC thermostat - how to set the parameters of the thermostat?

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC thermostat wiring needs to pay attention to RKC thermostat wiring needs to pay attention to

Wiring Notes: 1. For thermocouple input, the corresponding compensation wire should be used. 2. RTD input, 3 wires with low resistance and no difference should be used. 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference. ...

RKC Level Gauge – The structure of a float level gauge RKC Level Gauge – The structure of a float level gauge

(1) For the indicator, also known as the display panel, the indicator plays the role of local display, convenient for long-distance observation of the actual situation of the liquid level, the indicator is generally bundled with the pontoon, easy to install. (2) It is a magnetic float, which is located in the pontoon and is in direct contact with the liquid to be measured, ...

RLC thermostat - a detailed explanation of dry-type transformer thermostats RLC thermostat - a detailed explanation of dry-type transformer thermostats

The working principle of dry-type transformer thermostats The dry-type transformer temperature controller is a new generation of controller designed for the safe operation of dry-type transformers. The controller adopts single-chip microcomputer technology, and uses three platinum thermal resistors embedded in the three-phase winding of the dry-type transformer to detect and display the transformer.

RKC Thermostat - How to Choose a Hot Spot Couple? RKC Thermostat - How to Choose a Hot Spot Couple?

The selection of thermocouples should be based on comprehensive considerations such as the scale of the operating temperature, the required accuracy, the atmosphere of the application, the performance of the measurement target, the response time and the economic benefits. 1. Selection of measurement accuracy and temperature measurement scale 1) The operating temperature is 1300-1800 °C, and the accuracy is required to be more accurate than ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top