CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
1. RH400 size: 48*96, depth 60, about 250g
1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
2. Temperature measurement heat resistance input: PT100, JPT100
3. Tributary voltage: DC0 - DC5V, DC1 - DC5V
Sampling period: 0.5s
Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degrees Temperature measurement resistance: ± (0.3 + 1 digit of displayed value)
(DC0/12V) allowable load resistance above 600 ohms, can be heated and cooled dual output control (output 1: heating side; Output 2: Cooling side)
Optional heater disconnection alarm and control loop disconnection alarm
2. CH402 size: 48*96, depth 100, about 250g
1. Temperature measurement resistance input: PT100, JPT100
2. Tributary voltage: DC0 - DC5V, DC1 - DC5V
3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)
Sampling period: 0.5s
Optional heater disconnection alarm and control loop disconnection alarm
Optional 2-wire RS-485 communication
3. CD901 size: 96*96 depth 100, about 340g
1. Temperature measurement resistance input: PT100, JPT100
2. Tributary voltage: DC0 - DC5V, DC1 - DC5V
3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)
Multiple alarm types: upper limit input value, lower limit input value, upper limit deviation, lower limit deviation, upper and lower limit deviation, upper and lower range setpoint, lower limit setpoint (standby operation can be attached)
Sampling period: 0.5s
Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degree temperature measurement resistance: ± (0.3% of displayed value + 1 digit) or ± 0.8 degrees tributary voltage/current input: ± (0.3% of displayed value + 1 digit)
(DC0/12V) Allowable load resistance 600, used to drive TRIAC (three-terminal bipolar thyristor) trigger output: Trigger mode - zero cross method, on-current: 50 mA (50 degrees), 70 mA (25 degrees) for zero cross type medium capacity TRIAC (used to drive loads below 100 a) * Heating/cooling type is not possible TRIAC (three-terminal bidirectional thyristor) Output: Rated value 0.5 A (ambient temperature 40 degrees or less)
Optional heater disconnection alarm and control loop disconnection alarm
Optional 2-wire RS-485 communication
4. FB900 size: 96*96*60
Abundant inputs and outputs
Automatic/manual, local/remote direct switching
Multi-area function: Up to 8 different settings can be registered for the master setting, etc., and cumbersome settings can be changed in a lump package. Zones can also be switched via an optional external contact input.
By combining the multi-storage function to connect the number of the other area, the duration of the area, and the setting of the limit of the rate of change, it is possible to run the program up to 16 segments (8 steps).
Frequently used data (up to 16 items) can be freely listed in consecutive addresses, which greatly reduces data transmission and enables high-speed communication.
Joint operation can be carried out using communication
PID control: The sampling cycle can be switched to 0.05s, which corresponds to the high-speed heating process. A new type of heat-and-cool PID that inhibits undershoot on the cooling side. You can switch between the controls of "heating, cooling, heating and cooling, and position ratio".
5. CH102 size: 48*48, depth 100mm about 170g
1. Temperature measurement resistance input: PT100, JPT100
2. Tributary voltage: DC0 - DC5V, DC1 - DC5V
3. Tributary current: DC0-20MA, DC4-20MA (250 ohm external resistance required)
Sampling period: 0.5s
Measurement accuracy: Thermocouple: ± (0.3% of displayed value + 1 digit) or ± 2 degree temperature measurement resistance: ± (0.3% of displayed value + 1 digit) or ± 0.8 tributary voltage/current input: ± (0.3% of displayed value + 1 digit)
Control output: relay contact output: 1c contact (AC250 3A) resistance load voltage pulse output: (DC0/12V) allowable load resistance above 600 ohms current output: (DC4 - 20MA) allowable load resistance above 600 ohms can be heated and cooled dual output control (output 1: heating side; Output 2: Cooling side)
Optional heater disconnection alarm and control loop disconnection alarm
Optional 2-wire RS-485 communication
|
More on that
|
RKC Level Gauge – Some installation requirements for pontoon level gauges
1. The installation of the level gauge must be vertical to ensure that the inner pontoon can move up and down freely in the pipe body.
2. Install a shut-off valve between the container and the liquid level gauge to clean and overhaul the liquid level timing to cut off the material.
3. No magnets are allowed to approach around the main body of the pontoon level gauge, otherwise ...
|
|
RRC Thermostat – Instructions for use of smart thermostats
1. Turn on the power of the smart thermostat, and the current temperature is displayed on the display. Because the sensor is not in contact with other devices, but is exposed directly to the air, this is the current temperature: 31 degrees Celsius, which is not too hot.
2. At the bottom right of the display is the "Startup Temperature" setting.
|
|
What are the common devices for RKC thermostats – digital displays?
In a variety of electronic control equipment, digital display has become an indispensable and important link. The electronic devices and corresponding driving circuits used for digital display are called digital displays.
Commonly used digital displays include glow digital tube displays, fluorescent digital tube displays, projection ...
|
|
RK Thermostat - 5 Common Faults of Thermostat and Solutions
1. After heating for a period of time, it is found that the temperature has not changed, and the temperature has been displayed at the time of the ambient temperature.
In this case, you need to check that the SV value setting value is set, whether the OUT value indicator of the meter is not lit, and whether the No. 3 and 4 segments of the universal meter are 12VD ...
|
|
RK thermostat - the use and adjustment of temperature control instruments
1. Set temperature: Press the SET button to set or check the temperature set point. Press the SET button at the beginning of the digital tube character flashing, indicating that the appearance has entered the setting state, press the △ key to add the set value, press the v key to decrease the setting value, press and hold the △ key or √ key The data will change rapidly, press the SET key again ...
|
|
RK thermostat - classification and precautions for use of central air conditioning thermostat
1. The principle of central air conditioning thermostat
Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...
|
|
RRKC thermostat wiring installation and some precautions
The rkc controller was developed by Japan and is mainly used in plastics and stoves. Of course, it is also widely used in China's industry, there are many people who do not know much about the rkc controller, and some even feel unfamiliar.
|
|
Introduction to the functions of the RKC temperature control meter
(1) RH400 size: 48*96, depth 60, about 250g
Details:
●A variety of input types are available:
1) Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
2) Temperature measurement RTD input: PT100, JPT100...
|
|
RKC converters – what are the functions of converters?
1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components.
2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...
|
|
RLC Thermostat – How to use a smart temperature controller
1. Set temperature: press and hold the SET key, at this time the tube character begins to flash, proving that the instrument has entered the set state, increase the up button, decrease the down button, and press and hold the up and down buttons to quickly change, when the desired temperature is reached, then press the SET button The instrument is set.
2. Return control: press SET ...
|
|
RKG thermostat – how the temperature controller sets the parameters
1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
RKC Thermostat The structure, action principle and use of some commonly used relays
A relay is an electrical appliance that works automatically. When the amount of electricity such as voltage, current, and frequency or non-electricity such as temperature, pressure, and rotational speed is input to the relay, and when the specified value is reached, the contacts of the relay connect or cut off the circuit that controls or protects it. Relays are widely used in motor control and power ...
|
|
RHK thermostats – an introduction to the classification of displays
(1) Categorize by display color
1. Monochrome display
There are two types of displays: multi-grayscale monochrome display and VGA multi-frequency monochrome display. These displays are small, lightweight, clear and inexpensive, making them suitable for highly mobile workplaces.
2. Color ...
|
|
Difference Between Thermocouple and RTD
In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different.
This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.
|
|
RKC Thermostat – How to Maintain the Instrument?
The normal operation of the instrument is inseparable from the on-site maintenance relationship, especially some important process links, once there is a leak, it will greatly affect the quality of the product, resulting in heavy losses.
First of all, it is common to install both remote and field-indicated level gauges on important tanks.
|
|
Introduction to the types of alarms for RKC thermostats
* Alarm table {ALM1} (standard built-in)
A: Upper limit deviation alarm G: Standby upper and lower limit deviation alarm attached
B: Lower limit deviation alarm H: Upper limit input value alarm
C: Upper and lower limit deviation alarm J: Lower limit input value alarm
D: Alarm in the range K: Attached standby ...
|
|
RLC thermostat - temperature controller control method classification and working principle
1. The temperature controller control method is generally divided into two types:
One is controlled by the temperature change of the cooled object, and the vapor pressure temperature controller is mostly used, and the other is controlled by the temperature difference change of the cooled object, and the electronic temperature controller is mostly used.
...
|
|
How to set the parameters of the RCRS400 thermostat
1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again ...
|
|
Where you need to pay attention to the wiring of the RRKC thermostat
1. For thermocouple input, the corresponding compensation wire should be used.
2. RTD input, 3 wires with low resistance and no difference should be used.
3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference.
4. Instrument power cord ...
|
|
What are the solutions to the failure of the RRKC thermostat - the sudden thermostat?
1. The cleanliness and finish of the contact surface have a great impact on the working condition of the contact. When the surface of the contact is rough or there is excess material on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate excess materials; Increasing the process of screening excess materials, ...
|
|