RKC thermostat Digital display controller parameter setting method

Create Date: 2024-8-30 12:03:23|Source: RKC

A digital display controller is a simple controller with indication, control, remote transmission and alarm functions. As a secondary instrument commonly used in sensors, it is very important to operate and use it correctly. Applications such as level control, temperature control, pressure control and parameter value display of measured variables.
       RKC thermostat Digital display controller parameter setting method
Sensors commonly used in digital display controllers.

Temperature sensors include thermocouples and RTDs, transmitters include pressure transmitters, differential pressure transmitters, liquid level transmitters, and flowmeters include electromagnetic flowmeters, vortex flowmeters, etc.

The digital display controller can receive the signal.

Resistance signal, electrically coupled signal, standard electrical signal 1-5VDC or 4-20ADC, non-standard electrical signal 0-10ADC0-20ADC or 0-5VDC 0-10VDC.

The parameter settings of the controller are displayed digitally.

The parameter settings of the digital display controller include primary parameter setting and secondary parameter setting. The alarm function is usually set in the main parameter settings. The secondary parameter setting is important, and the choice of graduation number is important. There are eight thermocouple graduation numbers (BSRKTNJE), and two RTDs (Cu50PT100) are usually used, so it is necessary to memorize their graduation numbers. The indexing number of the commonly used sensor electrical signal has a standard current signal 4-20mAADC standard voltage signal 1-5VDC, the upper and lower limits of the range are set and the upper and lower limits of the output range of the transmitter are set, in which the small signal cutting can only be used in the flow transmitter, other transmitters can not be used, and other function settings can be selected according to the need. Generally, the common parameters can be set to meet the requirements.

The parameters of the digital display controller are set by input signal selection, which is generally set to ** item in the secondary parameters, and the decimal point is generally set to the secondary term. Parameters such as the upper and lower limits of the measurement range, the transmitter output signal setting, the alarm type, etc. There are different options due to the different models of digital display control instruments.

For the wiring of the digital display control instrument, due to the different types of the digital display control instrument, the terminal block is also different, which is usually displayed on the back of the instrument and can be followed by the wiring diagram.

More on that
RKC Thermostat Usage Warning RKC Thermostat Usage Warning

· Wiring warning: - If the instrument fails or an error occurs, which can cause a system failure, install external protection circuits to prevent such accidents; - To prevent damage or failure of the instrument, use appropriate fuses to protect the power cord and input/output cord from strong power shocks. ...

RK thermostat - the performance characteristics of digital display thermostat are introduced RK thermostat - the performance characteristics of digital display thermostat are introduced

1. The special integrated instrument chip has more reliable anti-interference and stability. 2. Signal input, ordinary heat signal can be connected through menu settings. 3. You can modify the display range, transmission output range, alarm value and online report J mode. 4. Soft ...

RKC thermostat - how to set the parameters of the thermostat? RKC thermostat - how to set the parameters of the thermostat?

1. Lower limit deviation alarm setting: press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RKC converters – what are the functions of converters? RKC converters – what are the functions of converters?

1. Power conversion: convert the voltage (rated 100V) and current (rated 5A or 1A) of the transformer into voltage (several volts) to meet the requirements of weak current components. 2. Isolation: current, secondary side security, and work grounding are used to ensure the safety of people and equipment, while weak current ...

RKC thermostat – the correct way to adjust the thermostat RKC thermostat – the correct way to adjust the thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character start flashing, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance will return ...

RKC thermostat How to quickly understand the wiring diagram of the thermostat RKC thermostat How to quickly understand the wiring diagram of the thermostat

There are many models of temperature controllers, and the output methods are slightly different, but the wiring principle is the same. The working principle of the thermostat: the main circuit of the power supply is directly connected to the heating device through the main contact of the AC contactor.

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1 Bellows or diaphragm air conditioner thermostat Fault Symptom: Poor contact or burning, resulting in the circuit cannot be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; Leakage of thermostat in the temperature sensing chamber, causing the contacts to fail to operate and lose control ...

What are the solutions to the failure of the RRKC thermostat - the sudden thermostat? What are the solutions to the failure of the RRKC thermostat - the sudden thermostat?

1. The cleanliness and finish of the contact surface have a great impact on the working condition of the contact. When the surface of the contact is rough or there is excess material on the contact, it is easy to cause arcing and reduce the life of the contact. Therefore, the parts cleaning process should be improved to eliminate excess materials; Increasing the process of screening excess materials, ...

RLC Thermostat – Instructions for installation and use of pop-up thermostats RLC Thermostat – Instructions for installation and use of pop-up thermostats

1. Grounding method: It is connected to the grounding metal parts of the equipment through the metal cover of the thermostat. 2. The thermostat should work in the general indoor environment where the relative humidity of the air is not more than 90%, and there are no corrosive gases, flammable gases and conductive dust. 3. The thermostat adopts contact ...

Steps for the correct adjustment of the thermostat Steps for the correct adjustment of the thermostat

1. First of all, determine the set temperature of the thermostat and make sure that it is the same as the temperature you need. 2. Recognize the operating form of the thermostat, usually there are two forms of cooling and heating, and choose the corresponding form according to the demand. 3. Acknowledging the operating condition of the thermostat, usually with active ...

RRKC thermostat - five common faults and solutions of smart thermostats RRKC thermostat - five common faults and solutions of smart thermostats

After heating for a while, the temperature does not change. Displays the ambient temperature of the site at all times (e.g. room temperature 25°C) In case of such a fault, first check whether the SV value setting value is set, whether the OUT indicator of the meter is lit, and whether the No. 3 and No. 4 terminals of the meter are 12VDC output with the "multimeter". ...

RKC thermostat wiring needs to pay attention to RKC thermostat wiring needs to pay attention to

Wiring Notes: 1. For thermocouple input, the corresponding compensation wire should be used. 2. RTD input, 3 wires with low resistance and no difference should be used. 3. The input signal line should be far away from the power line of the instrument. Power supply and load lines to avoid noise interference. ...

RKC Thermostat – What are the common faults of thermostats? RKC Thermostat – What are the common faults of thermostats?

1. There is no manifestation when the power is on. For this kind of problem, first confirm whether the power supply is there and whether the power supply matches the power supply required by the thermostat, and then check whether the wiring is strong. The problem is still there, then it is the problem of the thermostat itself. 2. There is a manifestation, and the manipulation makes mistakes. The first thing to look at this kind of problem is to look at the control ...

RRC thermostat - introduction to the working principle and classification of electronic thermostats RRC thermostat - introduction to the working principle and classification of electronic thermostats

Principle of electronic thermostat: The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, which has its own advantages and disadvantages. Household Air Conditioner Temperature Controller ...

RDC converters – a classification of power converters RDC converters – a classification of power converters

Motors are divided into two categories: DC motors and AC motors, and AC motors are divided into asynchronous motors and synchronous motors, and their respective speed regulation principles are also different. According to the speed regulation requirements of the motor, it can be divided into two categories: DC power converter and AC power converter: ...

RKC converter - an introduction to the classification of converters RKC converter - an introduction to the classification of converters

  Analog-to-digital converters The analog-to-digital converter comprises a first transmission circuit, which receives an input voltage and an output clock signal, which is phase-shifted, depending on the input voltage, and a second transmission circuit receives a reference voltage and an input clock signal, and outputs a reference clock signal, which ...

RTC thermostat - how to set the parameters of the thermostat RTC thermostat - how to set the parameters of the thermostat

1. Lower limit deviation alarm setting: Press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint. 2. The upper limit deviation alarm is set ...

RLC thermostat - common faults of temperature controllers and solutions RLC thermostat - common faults of temperature controllers and solutions

Fault 1: The device does not display after powering on Solution(s): First of all, check whether the terminals of the device have been connected to the neutral live wire, and make sure that the neutral live power supply can work normally. Then start to check whether the cable between the LCD motherboard and the device drive power supply is ...

The main role and service life of the thermostat - RLC The main role and service life of the thermostat - RLC

In most cases, in Europe, the thermostat is a necessary accessory for the wall-hung boiler, and the two are delivered to the user at the same time, and most of the thermostats equipped are intelligent thermostats. In China, nearly 95% of the wall-hung boilers that have been installed in operation and are being installed and debugged and ready to be put into use are not equipped in advance.

RKC thermostat - introduction of three wiring methods of thermal resistance RKC thermostat - introduction of three wiring methods of thermal resistance

1. The three wiring methods of Pt100 RTD are different in principle: The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top