RKC thermostat operation attention
· Clean the instrument only after the power is off;
· Please use a soft cloth or cotton paper to remove stains on the monitor;
· The display is easy to be scratched, it is forbidden to use hard object to operate the panel buttons, otherwise the keys will be damaged or scratched.
Key features:
Thermocouples, RTDs, analog and other signals are freely inputted, and the range can be set freely;
The software zeros the full degree, the cold end measures the temperature separately, the amplifier is self-stabilizing, and the display accuracy is better than 0.5%FS;
Fuzzy theory combined with traditional PID method to control fast and stable, tuning scheme;
Outputs selectable: cut-off contacts, logic levels, thyristor single-phase or three-phase zero-crossing or phase-shifting triggers, pulses or shifts, analogues. Two definable alarm point outputs are also included.
|
More on that
|
RKC Level Gauge – the correct way to use the float level gauge
(1) Before use, first check whether the level gauge is within the verification cycle, otherwise, it should be calibrated, and replaced in time if it is unqualified.
(2) The sensor should be installed horizontally, and the length of the lower entry should meet the technical requirements.
(3) The connection between the sensor and the explosion-proof junction box should be tightened and tightened.
|
|
RK Level Gauge - Introduction to the characteristics of float level gauge
It is suitable for measuring the level and interface of the liquid medium in the container. In addition to on-site instructions, it can also be equipped with remote transmitters, alarm switches, and detection functions.
The indication is novel, the reading is intuitive, eye-catching, and the direction of the observation indicator can be changed according to the user's needs.
Large measuring range ...
|
|
Initialization parameter setting of the rkc thermostat
1. Press the ISET) button for 2 seconds to enter the parameter setting mode, press ISET until "LCK" is displayed, press the [] key to move the cursor to the thousands, and press the [] button to change the number of thousands from "0" to "1" to display "1000" to unlock.
2. Press the ISET button for 3 seconds to return to SV/PV display mode
3. Press [SET]+ ...
|
|
Specifications and models of RKC thermostats
CH102 (48×48×100mm)
CH402 (48×96×100mm)
CH902 (96×96×100mm)
1. RH400 size: 48*96, depth 60, about 250g
1. Thermocouples: K, J, R, S, B, E, N, T, W5RE/W6RE, PL‖, U, L
...
|
|
What should I pay attention to when setting up my RKC thermostat?
Wiring Warning:
If the instrument fails or an error occurs, which can cause a system failure, an external protection circuit is installed to prevent such accidents:
In order to prevent damage or failure of the instrument, choose an appropriate fuse to protect the power cord and input and output lines from strong power shocks.
Power supply ...
|
|
RKC converter – the control strategy of the converter
Direct transformation method
The direct conversion method is to synthesize the "output voltage" through the continuous chopping of the input voltage, which can be divided into coordinate transformation method, harmonic injection method, equivalent conductivity method and scalar method, although all these methods have certain advantages, but also have certain problems, ...
|
|
RKG thermostat - an introduction to the relevant knowledge of temperature controllers
The temperature controller is an electrical switchgear that controls the temperature of an air-conditioned room. The temperature range in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C. The temperature controller commonly used in window air conditioners uses the principle of pressure to push the contacts on and off. Its structure consists of bellows ...
|
|
RKC Level Gauge – Precautions for the installation of float level gauges
1. The specific gravity of the liquid to be measured must be greater than the specific gravity of the float
2. The measured medium should not contain ferromagnetic impurities
3. The float level gauge should be installed in an unobstructed position when the float moves up and down
4. Magnets are not allowed to be close around the float level gauge, otherwise it will affect the float.
|
|
RHK thermostat - the use of electronic thermostat and its classification introduction
First, the use of electronic temperature controller
The electronic temperature controller (resistive type) is measured by the method of resistance temperature sensing, and generally uses platinum wire, copper wire, tungsten wire and semiconductor (thermistor, etc.) as the temperature measurement resistor, and these resistors have their own advantages and points. Home Air Conditioner ...
|
|
RLC thermostat – what you should pay attention to when maintaining your temperature controller
1. Do not wipe with acidic, alkaline and other corrosive liquids and water-containing rags when cleaning, so as not to damage the temperature controller and affect its normal use.
2. Do not decorate and cover the temperature controller. The thermostat has a built-in temperature sensor to sense the outside temperature. Therefore, Wen ...
|
|
RKC thermostat REX-C400 model settings and parameter instructions
Japan RIKA RKC REX-C400 temperature controller product introduction
REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay
1. Dual display set temperature and process temperature
2. General Digital Programmable Temperature ...
|
|
RLC thermostat – how to install the thermostat
1. In which room should the thermostat be installed?
It is very important to choose a reasonable location to install the thermostat, which will directly affect the work of the wall-hung furnace in your home, the main living room (living room) should be your best choice, you can also install the thermostat in the bedroom according to your personal needs.
|
|
Parameter setting operation of RLC temperature control table CH402
Model: CH402FS01-8*HN (for PECVD temperature control)
1) Single press SET: SV can be set (set temperature manually)
2) Press and hold the SET button for 2 seconds, ALI=1000 (absolute alarm temperature setting) and then press the SET button, ATU=1 (self-defining, self-interpreting a set of PID parameters) to exit ...
|
|
RTC thermostat - how to set the parameters of the thermostat
1. Lower limit deviation alarm setting: Press the SET key to select and display "SLP", the green display screen displays the value of the parameter, and select the shift, increment, and decrement keys to set or modify the parameter. This parameter indicates the difference between the alarm point and the master setpoint.
2. The upper limit deviation alarm is set ...
|
|
What are the technical parameters of the rkc thermostat - the jump thermostat?
1. Electrical parameters: (1) VDE, CQC, UL, TüVAC250V 50-60Hz 10A (resistive load) (2) ULAC125V 50Hz 15A (resistive load)
2. Operating temperature range: -50-270°C (optional), temperature accuracy: ≥ ±2°C
3. Reset and action ...
|
|
RKC Thermostat – How to Maintain the Instrument?
The normal operation of the instrument is inseparable from the on-site maintenance relationship, especially some important process links, once there is a leak, it will greatly affect the quality of the product, resulting in heavy losses.
First of all, it is common to install both remote and field-indicated level gauges on important tanks.
|
|
RKC Level Gauge – How to properly use a plug-in float level gauge for level measurement
1. Select the appropriate level gauge
First of all, it is necessary to choose the appropriate level gauge. The following factors should be taken into account in the selection of a level gauge:
Measure the properties of the medium: e.g., temperature, pressure, viscosity, corrosiveness, etc.
Measuring range: i.e. the height range of the liquid ...
|
|
RK thermostat - classification and precautions for use of central air conditioning thermostat
1. The principle of central air conditioning thermostat
Mechanical thermostats can be divided into vapor pressure thermostats, liquid expansion thermostats, gas adsorption thermostats and metal expansion thermostats. Among them, the vapor pressure thermostat is divided into inflatable type, liquid-gas mixed type and liquid-filled type. Domestic...
|
|
Common faults in the use of RKC thermostat Pt100 RTD
PT100 RTD is a platinum RTD, which can be regarded as a more commonly used thermometer in the range of medium and low temperatures, and it has a wide range of uses, including medical, electric, industrial production, thermometers and other high-precision thermometers. But due to the range of use ...
|
|
RKC thermostat - introduction of three wiring methods of thermal resistance
1. The three wiring methods of Pt100 RTD are different in principle:
The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...
|
|