What should I pay attention to when operating the RKC thermostat?

Create Date: 2024-8-30 12:03:23|Source: RKC

The instrument can be cleaned only after the power is off;

To remove stains from the monitor, use a soft cloth or cotton paper;

The display is easy to be scratched, and it is forbidden to use hard objects to operate the panel buttons, otherwise the keys will be damaged or scratched.
What should I pay attention to when operating the RKC thermostat?


More on that
RKC thermostat - introduction of three wiring methods of thermal resistance RKC thermostat - introduction of three wiring methods of thermal resistance

1. The three wiring methods of Pt100 RTD are different in principle: The two-wire system and the three-wire system are measured by the bridge method, and the relationship between the temperature value and the analog output value is given after ***. There is no bridge on the four wires, it is completely just sent with a constant current source, measured by a voltmeter, and the test is given after *** ...

RKG thermostat - an introduction to the characteristics of digital displays RKG thermostat - an introduction to the characteristics of digital displays

1) It is a display of the common cathode. It uses the principle of the positive electrode as the segmented input, with the ground wire as the common output, and the segmented input is valid as a high-level input. 2) It is a display with a common anode. It uses an anode as an aggregate input, and in contrast to the common cathode, the segment is effective at a low level output ...

RKC thermostat operation attention and its main features RKC thermostat operation attention and its main features

RKC thermostat operation attention · Clean the instrument only after the power is off; · Please use a soft cloth or cotton paper to remove stains on the monitor; · The display is easy to be scratched, it is forbidden to use hard object to operate the panel buttons, otherwise the keys will be damaged or scratched.   Key features: ...

RHK thermostat – a rapid detection method for common air conditioner thermostats RHK thermostat – a rapid detection method for common air conditioner thermostats

1. Bellows or diaphragm air conditioner thermostat 1. Fault phenomenon: poor contact or burning, resulting in the circuit can not be connected; The frequent action of the contact arc and sticking causes the circuit to be unbreakable; The thermostat in the temperature sensing chamber leaks, causing the contact to fail to operate and lose control. ...

RKC level gauge - the fault and treatment method of float level gauge RKC level gauge - the fault and treatment method of float level gauge

Fault 1, the indication is abnormal The float level gauge is not indicated properly and is a very common fault of the float level gauge. Usually there are the following manifestations: Phenomenon 1: The float level gauge in the atmospheric pressure workshop has the largest indication. Troubleshooting: The float was found to be ...

Common faults and analysis of thermostats Common faults and analysis of thermostats

Common faults of thermostats 1. There is no display when the power is on. This type of problem first determines whether the power supply is available and whether the power supply matches the power supply required by the thermostat, and then checks whether the wiring is secure. The problem is still there, then it is the problem of the thermostat itself. 2. There is a display, and the control is wrong. This...

RRKC thermostats – how are temperature controllers wired and commissioned? RRKC thermostats – how are temperature controllers wired and commissioned?

1. Take out the room temperature controller, and then connect the power supply terminal of the temperature controller to the power supply according to the terminal diagram of the temperature control chart 2. Then take out the temperature sensor that comes with the temperature controller and detect it 3. According to the temperature controller terminal, the temperature sensor is connected to the controller's transmission.

Introduction and wiring method of Japan physical and chemical RKC thermostat Introduction and wiring method of Japan physical and chemical RKC thermostat

  The core control algorithm of the temperature regulator is PID control, P (Proportional) ratio + I (Integral) point + D (Differential) differential control. In addition to the traditional PID control algorithm, RKC also has ON-OFF control, custom parameter control, adaptive parameter control and other algorithms, ...

RKC thermostat REX-C400 model settings and parameter instructions RKC thermostat REX-C400 model settings and parameter instructions

Japan RIKA RKC REX-C400 temperature controller product introduction REX-C400 Digital Thermostat RKC PID Temperature Controller Thermostat (SSR Output) + Type K Thermocouple + *Large 40A SSR Relay 1. Dual display set temperature and process temperature 2. General Digital Programmable Temperature ...

RRC thermostat - how to adjust the smart thermostat RRC thermostat - how to adjust the smart thermostat

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET button digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, long press the △ key or ▽ key The data will change rapidly, press the SET key again ...

Common faults in the use of RKC thermostat Pt100 RTD Common faults in the use of RKC thermostat Pt100 RTD

  PT100 RTD is a platinum RTD, which can be regarded as a more commonly used thermometer in the range of medium and low temperatures, and it has a wide range of uses, including medical, electric, industrial production, thermometers and other high-precision thermometers. But due to the range of use ...

RLC thermostat - a detailed explanation of dry-type transformer thermostats RLC thermostat - a detailed explanation of dry-type transformer thermostats

The working principle of dry-type transformer thermostats The dry-type transformer temperature controller is a new generation of controller designed for the safe operation of dry-type transformers. The controller adopts single-chip microcomputer technology, and uses three platinum thermal resistors embedded in the three-phase winding of the dry-type transformer to detect and display the transformer.

RRKC thermostat – the correct way to set up the thermostat RRKC thermostat – the correct way to set up the thermostat

Press the SET button to set or view the temperature set point, press the SET key digital tube characters to start flashing, indicating that the instrument has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The instrument returns to normal working condition ...

RLC Level Gauge - Classification and construction of pontoon level gauges RLC Level Gauge - Classification and construction of pontoon level gauges

1. Classification of pontoon level gauges The pontoon level gauge is also divided into two types: inner pontoon and outer pontoon, the so-called internal and external division refers to the place where the pontoon is installed, in the container of the liquid to be measured is the inner pontoon, and the outer pontoon is called the outer pontoon outside the liquid container to be measured.

RHK thermostat - common faults and maintenance methods of thermostats RHK thermostat - common faults and maintenance methods of thermostats

1. Thermostat contact contact failure Poor contact of the thermostat contacts will cause the compressor to not operate properly. If the contacts are sticky, the compressor will fail without downtime. For this, you can use a small screwdriver to open the metal shell of the thermostat, and then use a fine abrasive cloth to polish the surface of the contacts ...

RKC Temperature Control Meter - How to set the temperature control meter RKC Temperature Control Meter - How to set the temperature control meter

1. Turn on the power supply of the smart thermostat, and the temperature displayed on the screen is the temperature at that time. Because the sensor is not in contact with other devices, but is directly exposed to the air clock, this is the current temperature: 31 degrees Celsius, which is not too hot. 2. At the bottom right of the display screen is the "starting temperature" setting ...

Difference Between Thermocouple and RTD Difference Between Thermocouple and RTD

In temperature measurement, thermocouples and RTDs are both contact temperature measurements, and although they both measure the temperature of an object, their principles and characteristics are different. This article first introduces thermocouples, which are widely used in temperature measurement temperature control devices.

RLC thermostat - common faults of temperature controllers and solutions RLC thermostat - common faults of temperature controllers and solutions

Fault 1: The device does not display after powering on Solution(s): First of all, check whether the terminals of the device have been connected to the neutral live wire, and make sure that the neutral live power supply can work normally. Then start to check whether the cable between the LCD motherboard and the device drive power supply is ...

The debugging method of the temperature controller The debugging method of the temperature controller

Generally, there are three buttons to provide the need for setting, one is the Set button, press it once to enter the setting state. The other two offer upward and downward temperature adjustments, which can be adjusted to any temperature point. After adjusting to the desired temperature point, press the Set button again to confirm. 1. Turn on the smart thermostat ...

RKC thermostat - common faults and solutions of temperature control instruments RKC thermostat - common faults and solutions of temperature control instruments

1. Heating for a period of time, the temperature does not change. The ambient temperature of the site (e.g. room temperature 25°C) is displayed at all times. In case of such failures, first check whether the SV value setting value is set, whether the 0UT indicator light of the meter is lit, and whether the No. 3 and No. 4 terminals of the meter with the "multimeter" are 12VD ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top