Delta's inverter is powered on and commissioned

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

After the installation of the Delta inverter is completed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on to ensure that there is no short circuit, and then turn on the operating power supply of the inverter (pay attention to whether the operating power supply voltage calibrated by the inverter is consistent with the external input voltage), and recognize whether the factory settings of the parameters are consistent with the working conditions, such as the additional frequency of the motor, the input voltage, the type of simulated input/output signals, etc., if these signals are consistent with the operating conditions, These parameters can be set without setting, just stick to the factory settings.

                               Delta's inverter is powered on and commissioned

There are some parameters that need to be preset before commissioning, such as: external terminal operation, analog quantity operation, substrate frequency, high frequency, upper and lower frequency, lower limit frequency, start-up time, braking time (and mode), thermoelectronic maintenance, overcurrent maintenance, carrier frequency, stall maintenance and overvoltage maintenance.

There are also some parameters that are adjusted according to the operation status during the commissioning process, such as operation frequency, acceleration time, deceleration time, 1-stage speed, 2-stage speed, 3-stage speed, imitation output share adjustment, etc. After the Delta inverter is set, connect the motor, start the motor, and at a given speed, it should operate normally, paying attention to whether the DC bus voltage, inverter output current, torque, power and other data are normal.

More on that
Precautions for the use of Delta inverter MS300 series Precautions for the use of Delta inverter MS300 series

Before operating the MS300 series products, please read and pay attention to the relevant safety information to ensure your own safety and product safety. When operating the wiring and installing the inverter, it is necessary to confirm that the power supply is closed. After blocking the communication power supply, the inverter POWER indicator (located in ...

Delta's inverter composition and function Delta's inverter composition and function

Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to complete the variable speed operation of the motor, in which the control circuit completes the control of the main circuit, the rectifier circuit converts the communication power into direct current, and the output input of the DC center circuit to the rectifier circuit is ...

Delta's MZM position drive system is used for precise application of large inertia Delta's MZM position drive system is used for precise application of large inertia

Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end ...

Delta's inverter is automatically changed to manual setting Delta's inverter is automatically changed to manual setting

The converter is capable of manual and active switching: 1. The switching between the manual operating system and the DCS operating system is done by the transfer switch SA installed on the field operation tower, which has active, manual and ...

Delta's SCARA industrial robots help replace machines in the electronics manufacturing industry Delta's SCARA industrial robots help replace machines in the electronics manufacturing industry

Project Background At present, electronic products such as mobile phones, computers, and IPads have become the standard in people's lives, which also promotes the rapid development of the electronic manufacturing industry. PCB (printed circuit board) is an important component in electronic products, with the trend of electronic products towards high-end, miniaturization ...

Basic parameter setting of special inverter for wind turbine - Delta Basic parameter setting of special inverter for wind turbine - Delta

1. Control mode: i.e. speed control, torque control, PID control or other methods. After the control method is adopted, static or dynamic identification should generally be carried out according to the control accuracy. 2. Minimum operating frequency: That is, the minimum speed of the motor. When the motor is working at low speed, the ...

The principle, composition and function of Delta's inverter The principle, composition and function of Delta's inverter

1. What is a Delta inverter? Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to realize the variable speed operation of the motor.

Delta inverter repair steps Delta inverter repair steps

Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look. ...

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of a hundred flowers blooming, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

Delta's inverter failure analysis Delta's inverter failure analysis

1. Fault code: SE1 parameter replication error Fault Description: Keypad replication function error correct Solution: Keypad replication action errors, including communication delays, communication errors (Keypad received FF86 errors), and parameter value errors ...

Troubleshooting of small electromagnetic relay cores - Delta Troubleshooting of small electromagnetic relay cores - Delta

The main problems of the iron core of the small electromagnetic relay are that the armature cannot be sucked after being electrified: This may be due to broken coils, foreign matter between the moving and static cores, and low power supply voltage. It should be patched on a case-by-case basis. When energized, the armature is noisy: This may be because of the ...

Delta UPS uninterruptible power supply R-2K series Delta UPS uninterruptible power supply R-2K series

With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.

Precautions for the inverter installation environment – Delta Precautions for the inverter installation environment – Delta

(1) Ambient temperature: Like other electronic equipment, the inverter has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is very easy to be affected by the working temperature, but in order to ensure the safety of the inverter's work.

Delta's inverter process setting Delta's inverter process setting

1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, break ...

Delta NT series UPS industrial power supply Delta NT series UPS industrial power supply

Delta's NT series UPS is a high-power UPS carefully discussed by experts for large-scale users, and a number of advanced skills have been selected, which can be used for various data processing systems, telecommunications systems, satellite systems, network systems, medical equipment, safety and emergency escape equipment, monitoring and security systems, and various industrial systems.

Methods for preventing and controlling high-current contactor contact heat - Delta Methods for preventing and controlling high-current contactor contact heat - Delta

The key to dealing with the heat of the high-current toucher is to make the contact tightly connected to the copper braid so that it does not loosen. Useful methods of prevention and control are as follows: (1) The copper braid and the moving contact touch are made with a mixture of 60% tin and 40% lead.

Precautions for Delta's DPA pressure sensor Precautions for Delta's DPA pressure sensor

1. When the device is installed, leave the place with high voltage and strong high-frequency noise to prevent disturbance. Prevent use in places where the following conditions occur: (a) Excessive dust and corrosive gases; (b) high humidity and very high radiation; (c) ...

Delta's servo protection parameters are written Delta's servo protection parameters are written

A3, B3 servo P5-97 Motion Control Mobilization Commands 0x0003 Maintenance Activation (Successful Return 0x1003) 0x0004 Maintenance Waiver (Successful Return 0x1004) If the wrong cipher code is entered, the error code Ennn will be sent back to exempt the loss, during which nnn indicates that there is a ...

Features of two-phase electric fan inverter - Delta Features of two-phase electric fan inverter - Delta

With the continuous development of science and technology, there are more and more types of domestic machinery and equipment, and the upgrading of equipment is getting faster and faster. So what are the characteristics of two-phase electric fan inverter and whether it is worth choosing for enterprises. ...

Introduction to the inverter selection strategy - Delta inverter Introduction to the inverter selection strategy - Delta inverter

1. Ability to adapt to the environment 1.1 Ability to adapt to grid voltage fluctuations When the motor on the bus starts in a group, when the largest motor unit on the bus starts, the influence on the operation of the inverter, which is related to the input voltage fluctuation range parameters promised by the inverter.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top