Delta's inverter failure analysis

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1. Fault code:

SE1 parameter replication error

Fault Description:

Keypad replication function error correct

Solution:

Keypad replication action errors, including communication delays, communication errors (Keypad received FF86 errors), and parameter value errors

                               Delta's inverter failure analysis

2. Fault code:

  CE10

Fault Description:

Communication Transmission Timeout: The Modbus transmission between the VFD and the Keypad times out

Solution:

The VFD does not respond to Keypad's communication commands.

1) Recognize the communication quality of communication wiring and contacts.

2) Please use the RESET key to eradicate the Fault.

3) Power on the whole machine again for the boot procedure. If the above methods are ineffective, they will be sent to the factory for maintenance.

3. Fault code:

  PFbF

Fault Description:

Pressure feedback disconnection

Solution:

1) Check whether the wiring of the pressure sensor is correct

2) Check whether the pressure sensor signal is lower than 1V
More on that
Selection of Delta power supply Selection of Delta power supply

There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?   VX Series Power Supplies. VX270: Active PFC270w, but 12v is still small and can only be used at low power. Active PFC and 12v output up to 276w at 300...

Several veins of the inverter circuit - Delta inverter Several veins of the inverter circuit - Delta inverter

1. Vibration circuit: the leakage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels of the power supply operation current; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

Delta's DTK series thermostat product model Delta's DTK series thermostat product model

DTK4848C01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, 4-20mA output, 1 alarm DTK4848R01 High brightness LCD display, 48*48, Pt resistor/thermocouple input, relay output, 1 alarm DTK4848V01 Highlight ...

The cause of inverter heating - Delta inverter The cause of inverter heating - Delta inverter

1. The problem of the inverter and the motor itself If the motor has been used for a long time, it is not good to clean the insulation function, or the bearing may be stuck, and it may show a large current and heat. The coupling between the motor and the load may also be worn, or the motor is unbalanced, the fixtures of the motor are loose, etc.

A number of Delta's new high-end power supply products were unveiled at CMEF A number of Delta's new high-end power supply products were unveiled at CMEF

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

TIMTOS x TMTS 2022 - Delta's Exhibit Highlights TIMTOS x TMTS 2022 - Delta's Exhibit Highlights

Intelligent machining solution plan Intelligent machinery is an important step towards intelligent manufacturing, in order to help manufacturers improve productivity or complete a few diverse forms of production, Delta will exhibit the intelligent processing solution plan at TIMTOS x TMTS 2022, which will be used to communicate with industrial-grade managed Ethernet networking.

EMC Filter Installation Considerations – Delta EMC Filter Installation Considerations – Delta

All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...

The inverter needs to prepare the braking resistance condition - Delta The inverter needs to prepare the braking resistance condition - Delta

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to prevent the capacitor voltage from being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and prevent energy waste. However, the capacitance of the capacitor is ...

Problems in the inverter application – Delta inverters Problems in the inverter application – Delta inverters

1. Harmonic problems The equipment that plays the role of switching in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics generally have a greater impact on the motor load and cause torque ripple; The higher harmonics increase the leakage current of the inverter's output cable, making ...

Delta's A2 server maintenance location controller is faulty Delta's A2 server maintenance location controller is faulty

Delta's A2 series servo system is one of the more common and used servers on the market today, and the following describes the fault details of the azimuth controller in the repair of Delta's A2 servo drive and the corresponding repair methods Delta ...

Wind turbine inverter speed regulation effect - Delta Wind turbine inverter speed regulation effect - Delta

What is the effect of speed regulation of fan inverter? According to the query materials, in industrial production, the throttling loss of the damper, baffle and other related equipment of the fan, as well as the protection and maintenance costs account for 7%-25% of the production cost.

Delta's touch screen controls the inverter method Delta's touch screen controls the inverter method

1. The touch screen is controlled by PLC inverter 1. Now the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

Introduction to Delta's DVPSCM52-SL communication module Introduction to Delta's DVPSCM52-SL communication module

Recently, Delta Group has made a big hit in the field of building automation with the launch of the DVPSCM52-SL, a slave communication module that supports BACnet MS/TP (Building Automation Control Network Communication Protocol). Building automation system is an indispensable part of intelligent building.

Introduction to common models and parameters of Delta touch screens Introduction to common models and parameters of Delta touch screens

There are many types of Delta contact screens, of course, the parameters of different types are different, and the most important product is DOP-B03S201. This product is a 4.3-inch screen, its aspect ratio is 16:9, the screen is made of TFT raw materials, and its resolution can reach 480X ...

PLC Peripherals – Delta PLC PLC Peripherals – Delta PLC

Programming equipment: simple programmer, most only accept mnemonic programming, and some can also be programmed graphically (such as Japan's Toshiba EX programmable controller). The cluttered one has a graphical programmer, which can be programmed in the trapezoidal language. Some also have dedicated computers that can be used for other ...

What are the problems of the inverter if it is not used for a long time - Delta What are the problems of the inverter if it is not used for a long time - Delta

Most inverter brand products can rely on the heat of internal electrical components to remove moisture during normal use. If you don't use it for a long time, it's easy to get wet. The chip pins, penetrating resistors, capacitors, and inductor pins of the DIP package will be severely rusted or desoldered, resulting in on-resistance ...

Precautions for the use of Delta inverters Precautions for the use of Delta inverters

1. The inverter must be selected correctly. 2. Read the product manual carefully, and wiring, device and application in accordance with the requirements of the manual. 3. The inverter device should be firmly grounded to suppress radio frequency disturbance and avoid electric shock caused by leakage of the inverter. 4、 ...

Delta's Ultron HPH provides power protection that meets the needs of green data centers Delta's Ultron HPH provides power protection that meets the needs of green data centers

Delta's Ultron HPH series UPS has an AC-AC efficiency of up to 96%, and can reach 99% in ECO mode, with significant energy savings. The flexible airframe provides a compact footprint (40kW / 0.15 m2) and reduces space waste. With an interface-friendly 5-inch colorful touch screen, ...

Description of Delta inverter problems and solutions Description of Delta inverter problems and solutions

Problem Description: What is stall avoidance? Solution(s): If the given acceleration and deceleration time is too short, the output frequency of the inverter changes faster than the motor speed, and the inverter will stop working due to overcurrent, which is called stalling. In order to make the motor ...

Selection of inverter box structure - Delta Selection of inverter box structure - Delta

The box structure of the inverter should be adapted to the environmental conditions, that is, the temperature, humidity, dust, pH, corrosive gas and other elements must be considered. There are several common types of structures that users can choose from: 1) Open IPOO ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top