(1) Ambient temperature:
Like other electronic equipment, the inverter has certain requirements for the ambient temperature, which is generally "-10-+40°C". Because the inverter is a high-power electronic equipment, it is easy to be affected by the working temperature, but in order to ensure the safety and reliability of the inverter, it should be considered to leave room when using, and it is best to control it below 40 °C; Derating between 40 and 50°C, the rated output current must be reduced by 1% for every 1°C increase. If the ambient temperature is too high and the temperature changes greatly, the insulation of the inverter will be greatly reduced, which will affect the life of the inverter.
(2) Ambient humidity:
The relative humidity of the surrounding air of the inverter ≤ 95% (no condensation), and the desiccant and heater must be added to the inverter cabinet if necessary according to the on-site working environment.
(3) Oscillation and shock:
In the process of operation, attention should be paid to prevent oscillation and impact. As we all know, the inverter is assembled by welding, screw connection and other ways of many yuan equipment. When the inverter or the control cabinet equipped with the inverter is subjected to mechanical oscillation or impact, it will cause the solder joints, screws and other connecting equipment or connectors to loosen or fall, causing severe faults such as poor electrical contact and even short circuit during the formation period. Therefore, in addition to improving the mechanical strength of the control cabinet and keeping away from the oscillation source and impact source, the inverter should also install a shock-resistant rubber gasket outside the control cabinet, and install a buffer rubber pad between the equipment and the device plate in the control cabinet to absorb the shock. Generally, after a period of operation of the equipment, the control cabinet should be inspected and protected.
(4) Electrical Environment:
●Prevent electromagnetic wave disturbance
The electrical body of the inverter is the hardware and software circuit of the power module and its control system, and when these components and software programs are subjected to certain electromagnetic disturbances, hardware circuit failures and software programs will occur to form operation accidents. Therefore, in order to prevent electromagnetic disturbance, the inverter should have a way to prevent electromagnetic disturbance according to the electrical environment in which it is located. For example, the input power line, output motor line, and control line should be far away; Vulnerable equipment and signal lines should be kept away from the inverter device as much as possible; Shielded cables should be used for critical signal lines, and it is recommended that the shielding layer be grounded by 360° grounding method.
●Prevent overvoltage at the input terminal:
The main circuit of the inverter is composed of power electronic equipment, which is very sensitive to overvoltage, and the overvoltage at the input end of the inverter will cause damage to the main components. For example, some factories have their own generators for power supply, and the power grid will fluctuate greatly, so there should be precautions against overvoltage at the input end of the inverter.
(5) Altitude:
The inverter device can output the rated power at an altitude of less than 1000m. However, at altitudes above 1000m, its output power decreases. As shown in Figure 1 of the altitude and output current of the inverter device address, it can be seen that the altitude exceeds 1000m, and the output current of the inverter decreases, and the output current is 40% when the altitude is 4000m, and the output current is 40% when it is 1000m.
Figure 1 Comparison of the altitude of the inverter device address with the output current
(6) Other environments:
●Prevent the inverter device from being dripping or condensing in the rain;
●Prevent the intrusion of dust, cotton wool and metal shavings;
●Prevent the inverter device from being used in the occasion of oil pollution and salt;
●Keep away from radioactive materials and combustibles.
|
More on that
|
Instrument classification standard - Delta
The appearance of the instrument is a comprehensive product of a variety of science and technology, with a wide variety of varieties, wide application, and constantly updated, with a variety of classification methods. According to the intention and use of the use of the main measuring instrument, car appearance, tractor appearance, marine appearance, aviation appearance, navigation instruments, control instrument ...
|
|
Misunderstandings in the application of Delta inverters
The capacity selection of the inverter is based on the rated power of the motor
Myth: The capacity selection of the inverter is based on the rated power of the motor
Compared with the electric motor, the price of the inverter governor is more expensive, so it is important to ensure that the ...
|
|
Selection of Delta power supply
There are many models of Delta's power supplies, and the currents and functions supported are also different, so how to choose?
VX Series Power Supplies.
VX270: Active PFC270w, but 12v is still small and can only be used at low power.
Active PFC and 12v output up to 276w at 300...
|
|
Delta launched the MZM, a high-power positional drive system
Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the deviation of orientation is not as easy as that of "small" items. To this end ...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Requires an inverter speed control application – Delta
Inverter is a kind of speed regulation equipment, where is there a place to use motor speed regulation, especially asynchronous motor speed regulation, will use inverter, now it is mainly used in industrial equipment on a large scale, because the motor is the heart of industry, and three-phase asynchronous motor occupies the vast majority of the share, ...
|
|
Measures to avoid soft failure of inverters - Delta
The ways to reduce the soft fault of the inverter are: 1. Detect the overvoltage and undervoltage of the inverter; 2. Detecting overcurrent is the most frequent phenomenon of frequency conversion alarm.
Generally, the overvoltage alarm is generally presented at the time of shutdown, and the primary reason is that the deceleration time is too short or the braking resistance and braking unit have ...
|
|
Introduction to Constant Power and Constant Torque in Frequency Conversion Speed Regulation - Delta
In general, factory motors are based on the additional speed values obtained at a given power frequency voltage (380 V, 50 Hz). If 380V is not reached under actual operating conditions, e.g. as long as 300V, 50 Hz, the voltage is significantly undervoltaged. Fundamentally, it cannot reach the extra rev value, due to the ...
|
|
Delta's active front-end inverter partner
The ubiquity of AC drives brings significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to form electromagnetic disturbance, which affects the power quality. It is especially significant in occupations with large loads such as lifting and elevators.
At this time, the inverter ...
|
|
Precautions for summer maintenance and maintenance of inverters - Delta
1. Check the operating status of the inverter, whether the voltage and current value during operation are within the normal range.
2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature is generally between -10 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C.
3. Avoid ...
|
|
The inverter reported the cause of the grounding fault - Delta
Regarding the grounding problem, it can generally be swept away after the following steps (because most of the inverters are not easy to detect the current measurement of Hall components, it is very important to sweep the grounding caused by external conditions, and alternative methods can be selected if there are conditions, and it is still an external problem to change a normal load to see whether it is a problem of frequency conversion or an external problem ...
|
|
The difference between a general-purpose inverter and a vector inverter - Delta
There are two main differences between vector inverter and general inverter, the first is high control accuracy, and the other is high output torque at low speed. It can output 150%-200% of the rated torque. It should be vector frequency conversion is to decompose the motor current into D-axis current and Q-axis current, where D-axis current is excitation current ...
|
|
Inverter environmental installation requirements and methods - Delta inverter
1. The environmental requirements of the inverter
Ambient temperature - 10 °C - 40 °C;
Ambient humidity: The relative humidity does not exceed 90% (no condensation);
Other occasions that require no direct sunlight, no corrosive gas and flammable gas, and less dust, with an altitude of less than 1000m.
...
|
|
Inverter technology is a motor control method – Delta
When you are using the motor, if you simply change the frequency, your motor will most likely be burned out. This problem is especially acute when the frequency is reduced. In order to prevent the motor from burning out, the inverter must change the voltage at the same time as the frequency.
...
|
|
New and old models of Delta drives
Delta's VFD series of inverters has established a wide brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with the most diversified choices ...
|
|
Analysis of common faults of Delta servo motors
1. The shaft current of the motor is generated
The current in the shaft-housing-base circuit of the motor is called the shaft current.
Causes of shaft current:
1) Magnetic field asymmetry;
2) There is a wave in the supply current;
3 ...
|
|
Identify the problem area of the inverter - Delta
In the process of inverter protection and maintenance, various problems are often encountered, such as field line problems, poor primary parameter settings or mechanical equipment shortcomings. If there is a defect in the inverter, how to distinguish which part of the problem is a little more detailed here.
...
|
|
Reduce the failure rate of Delta's inverters
Daily View Item 1:
Check whether the sound of the motor changes abnormally during operation, including whether there is vibration during the operation of the motor.
Project 2:
Check if the environment of the inverter unit has changed. For example, whether the ambient temperature is normal. Familiar with Delta's inverter ...
|
|
Introduction to Delta's PLC maintenance knowledge
1. Delta's PLC power on running light does not light up, and the ERROR flashes, the reason may be: no program
2. Delta's PLC cannot communicate with the computer, which may be: RS23 port is broken
3. Delta's PLC power light does not light up: The power supply is bad
...
|
|
Composition and function of Delta inverter
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor.
|
|