With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of a hundred flowers blooming, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... The functions of various controllers represented by programmable manipulators (PLCs) are gradually diversified and complex, so as to meet the requirements of intelligent, systematic and networked changes in modern production. Delta's AX3 series of professional PLC-based motion controllers equipped with CODESYS integrated development software channel is a new generation of PLC products for future intelligent production based on Delta's years of independent innovation and R&D experience and keen market observation.
As a member of Delta's AX series family using the CODESYS channel, the PLC-Based motion controller AX3 series has the same motion control function as its brother AX8 series, and also uses high-performance multi-center processors, built-in multiple communication ports and dedicated EtherCAT motion control network interfaces, and provides a motion control specification instruction library for international organizations, making it more suitable for simple machining equipment, electrical and electronic equipment on the basis of exquisite fuselage planning, testing equipment and other equipment are used automatically.
The AX3 is available in both standard and P2P versions up to 64 axes. In the case of Delta's AX308E model, the CPU has 16 DIs and 8 DOs built-in, and the EtherCAT real-time communication feature allows the host to quickly update and respond. It supports 8-axis motion control, and the minimum synchronization time can reach 1 ms; Built-in 2 sets of incremental encoders and 1 set of absolute encoders to ensure that the accuracy of motion control meets the needs; After the system is optimized by Delta, it can quickly identify the connection information of multiple brands of EtherCAT slaves, and complete a high degree of integration.
In the era of intelligent manufacturing, PLC not only has excellent functions, but also serves as an important data node in the industrial Internet, so communication ability is often the central requirement of modern PLC. In addition to supporting EtherCAT, the AX3 series also has two built-in Gigabit LANs, which support Modbus, EtherNet/IP and OPC UA communication protocols, and can be connected to HMI, HDMI LCD screens, MES, ERP, SCADA and other host computer equipment, to meet the all-round needs of customers from single machinery to overall automated production lines, and to meet the use of equipment automation transformation and promotion faster. In addition, it is equipped with USB ports, SD cards, high-speed digital I/O, ABS/INC encoders and other interfaces, which enrich the customer's construction configuration and improve the competitiveness of the equipment.
AX3 series mainframes use the new editing software DIADesigner+ as a project development tool. In addition, it supports the IEC61131 relevant motion function library, PLCopen MC specification function block and Delta self-speaking DMC function module, which can provide users with high performance power and convenience.
With the acceleration of the intelligent production process, users have very high requirements for the continuous promotion of the system. AX3 series supports all expansion modules (up to 32 units) of the high-performance general-purpose controller AS series, including various expansion modules such as digital I/O modules, analog modules, temperature modules, etc., as well as OPC-UA protocol, and can also build more economical remote I/O through RTU-ECAT and DVP expansion.
With the continuous promotion of the AX3 series, Delta's controllers used in the CODESYS channel have become more abundant and powerful, allowing users to have more choices in selecting Delta's motion controllers. Delta will also continue to enrich the composition of the AX3 family, and will launch various types of motion controllers in the future to promote the use of Delta in factory automation and mid-to-high-end OEM equipment.
|
More on that
|
DC governor overhaul method - Delta
DC governor is a kind of motor speed regulation equipment, including motor DC governor, pulse width DC governor, thyristor DC governor, etc. Generally, it is a modular DC motor governor, which integrates power supply, control and drive circuits, selects three-dimensional structure layout, and selects micro-power consumption elements for control circuits.
|
|
Introduction to the common sense of Delta inverter
The low-voltage fuse cannot be used as an overload maintenance for the motor.
It is necessary that the additional voltage of the fuse is greater than or equal to the operating voltage of the distribution line.
The additional current of the fuse must be greater than or equal to the additional current of the melt.
...
|
|
The case of Delta's multi-axis motion controller
The non-standard manipulator can be customized according to the practical needs of customers, because the non-standard manipulator has no specifications to follow, and there is no such kinematic model in the controller, so the development of the control system is difficult. Delta recently provided non-standard manipulators for pharmaceutical board manufacturers to supply control solutions ...
|
|
Delta's SCARA industrial robots help replace machines in the electronics manufacturing industry
Project Background
At present, electronic products such as mobile phones, computers, and IPads have become the standard in people's lives, which also promotes the rapid development of the electronic manufacturing industry. PCB (printed circuit board) is an important component in electronic products, with the trend of electronic products towards high-end, miniaturization ...
|
|
The reason for the shaking of the inverter for the motor - Delta
When using the motor dragged by the inverter, sometimes the motor flutters and the over-fire flutter may burn out the motor and cause immeasurable losses. So what is the reason for this phenomenon?
1. The motor is damaged ...
|
|
Delta's MH300 series technical specifications
Outstanding drive characteristics
The overload capacity is up to 150% / 60 seconds, 200% / 3 seconds, suitable for constant torque, variable torque, constant power and other loads
Support induction motor, permanent magnet synchronous motor, optional PG card for high ...
|
|
Delta inverter repair steps
Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look.
...
|
|
Advantages of sensorless vector control - Delta inverter
Excellent open-loop speed control without slip compensation
There is high torque at low degree, so there is no need to supply too much torque to enhance c. Lower loss, higher power
Higher power echoes – especially for stepped loads
Big...
|
|
Installation requirements for inverter energy consumption braking - Delta inverter
(1) The wiring interval between the braking unit and the inverter, as well as between the braking unit and the braking resistor, should be as short as possible (the wire length should be less than 2m), and the wire cross-section should meet the requirements of the braking resistor discharge current.
(2) The brake unit is working ...
|
|
Delta's Ultron HPH provides power protection that meets the needs of green data centers
Delta's Ultron HPH series UPS has an AC-AC efficiency of up to 96%, and can reach 99% in ECO mode, with significant energy savings. The flexible airframe provides a compact footprint (40kW / 0.15 m2) and reduces space waste. With an interface-friendly 5-inch colorful touch screen, ...
|
|
The principle, composition and function of Delta's inverter
1. What is a Delta inverter?
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to realize the variable speed operation of the motor.
|
|
When the Delta inverter is powered on, the uptube drive voltage is established
One is hardware, similar to the CPU reset circuit, which gives the downtube a short high-level drive pulse during the initial power-up, and then the voltage drops to 0 to cut off the downtube.
The second is the software, when the CPU is operating normally, it outputs a square wave pulse that only needs to be turned on by the lower three tubes, so that the upper tube ...
|
|
Problems in the inverter application – Delta inverters
1. Harmonic problems
The equipment that plays the role of switching in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics generally have a greater impact on the motor load and cause torque ripple; The higher harmonics increase the leakage current of the inverter's output cable, making ...
|
|
The inverter has a built-in PLC function - Delta
PLC progressive scanning standard work preparation.
Abundant programming language: instruction statements; ladder diagram; SFC。
Abundant instruction statements: 45 instruction varieties, including 28 root instructions and 17 usage instructions.
350 step law capacity.
uS-level root directives ...
|
|
Delta's powerful NT series industrial-grade UPS
Delta's NT series industrial-grade UPS has always been an ideal choice for applications that require high power safety due to their high reliability and high-density planning. IGBT high-frequency switching sinusoidal pulse width modulation technology planning, which makes UPS have good power supply quality, high efficiency, low heat loss, noise ...
|
|
Debugging Delta's inverter method
1. Acceleration and deceleration time
The acceleration and deceleration time is usually confirmed by the rise and fall of the frequency setting signal. In the commissioning of Delta inverters, it is often used to set a long acceleration and deceleration time according to the load and experience value, and the frequency rise rate of the motor must be constrained when it accelerates to avoid overcurrent. When slowing down, ...
|
|
Cause of Servo Motor Failure – Delta
1. The motor is broken shaft
1. The cause of the problem
(1) Unreasonable mechanical design leads to excessive radial load force;
(2) The load end is stuck or severely overloaded;
(3) The motor and reducer are not centered when installed.
2. Eliminate problems
(1) Check the ...
|
|
Precautions for storage of Delta inverter VFD-VE
It must be placed in a ventilated, dust-free, dry place.
The ambient temperature of the storage location must be in the range of -10°C to +40°C
The relative humidity of the storage location must be in the range of 0% to 90% and be free of dew.
...
|
|
PLC control belt conveyor soft start method - Delta
Belt conveyor is a kind of continuous conveyor, which is one of the most important types of stationary or escorted cranes. The belt conveyor is the use of friction to convey the dynamics, with belts, steel belts, steel fiber belts and chemical fiber belts as a kind of adaptation to the transmission of materials and traction operations.
|
|
Common problems of VFD control motors - Delta
Question 1. Why use a VFD to control the motor?
Speaking of this question, let's first take a brief look at these two devices. The motor is a rational load, which hinders the change of current, and a large change in current will occur when it is started. VFD, which is actually made up of a rectifier inverter circuit, ...
|
|