Delta NT series UPS industrial power supply

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Delta's NT series UPS is a high-power UPS carefully discussed by experts for large-scale users, and a number of advanced skills are selected, which can provide reliable and high-quality power supply for various data processing systems, telecommunications systems, satellite systems, network systems, medical equipment, safety and emergency escape equipment, monitoring and security systems, and various factory equipment.

                                  Delta NT series UPS industrial power supply

Excellent paralleling characteristics have become an important feature in evaluating large UPS. Delta's NT series UPS adopts the "modified distributed logic control method", and all UPSs in the parallel system are in a completely "equal" state of control. A common synchronous phase modulation method is used. Each UPS can "intelligently" adjust the synchronous tracking of each UPS located in the parallel system to the best state (the phase difference between each unit is almost zero) and dynamically adjust the load percentage in real time to complete high-precision load sharing. The digital planning based on high-speed microprocessors (3) and the common thermal compensation operation and control make it possible for up to 8 UPSs to be directly connected without adding an external parallel card or parallel cabinet, and only using loop communication cable connection to transmit real-time signals.

The use of computer simulation to assist the analysis and planning of the heat dissipation air duct and advanced IGBT high-frequency switching sinusoidal pulse width modulation technology planning so that the heat loss, low noise, small size and long life of the UPS, together with the selection of modular planning can reduce the mean time of repair (MTTR), so that the maintenance operation is easier, through the digital planning of the microprocessor, simplify the complex imitation circuit and a lot of reduction in the number of parts, so that the system is more safe and reliable. The planning of dual backup redundant auxiliary power supply and loop communication cable strengthens the reliability of the UPS system.

The battery is an important but fragile link in the UPS system. In this regard, Delta has planned a variety of comprehensive battery management plans for the NT series UPS.

The two-stage charging feature of uniform charging and floating charge can quickly restore the capacity of the battery pack, and limit the size of the charging current by setting the battery AH together to prevent the battery from overcurrent charging.

Using microprocessor detection technology, the discharge cut-off voltage of the battery pack can be automatically adjusted according to the customer's actual load to ensure that the battery will not be "deep discharge of small current".

The charging system with automatic temperature compensation function can automatically adjust the charging voltage according to the temperature, so that the high temperature is not overcharged, and the low temperature is not undercharged. When any battery in the battery pack leaks and touches the battery box, because the battery box shell has been grounded with the equipment, it forms a current loop to the ground, and sparks and high heat occur at the leakage place, which may cause the battery shell to overheat and burn. UPS has a built-in automatic detection circuit for battery ground errors, and when a battery ground fault occurs, UPS will announce a positive warning and cut off the solenoid switch on the battery side together, which can isolate the battery to prevent risks. With the powerful monitoring software, it can also set up a regular discharge test for UPS battery safety, activate the battery, and find the fault point of the battery pack in time.

NT series UPS has super load adaptability, whether it is instantaneous load, overload, short circuit or 3-phase power unbalanced inverter, it can maintain excellent output characteristics, and do proper maintenance to prevent damage to the load and the inverter itself.

Overload Capability :

50% overload can be maintained for 1 minute

25% overload can be maintained for 10 minutes

10% overload lasts for 1 hour

Inverter short-circuit capacity: 3 times of the rated current

Dynamic regulation of output voltage: 0-100% load abrupt change less than 5

With unbalanced load: at 100% unbalanced load, the phase voltage difference is less than 1%

The voltage phase shift is less than 2 degrees

Excellent input characteristics, it is well known that many higher harmonics occur due to the use of rectifier filter loads, which makes the power grid increasingly "polluted" Delta's NT series UPS inserts a 7% inductor at the input of the rectifier to reduce the input voltage depression (Notch). 12-pulse rectifier, passive harmonic filter, automatic harmonic filter, etc. are supplied together with the input harmonic plan. The input power factor and the harmonic component of the reduced input current can be greatly improved.

Different from the monitoring method of general small UPS, NT series UPS provides its common monitoring plan.

Through the cooperation of UPSentry, Delta UPS has become a true network UPS. UPSentry can be installed in Windows 98/2000 and Windows NT operating systems. And after the power failure, the UPS discharge is at the end of the network, and all the computers equipped with UPSentry on the network are told to carry out normal shutdown procedures, no matter which of the above operating systems can operate normally.
More on that
Precautions for long-term idle use of Delta inverter Precautions for long-term idle use of Delta inverter

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems: ...

Delta's inverter product model Delta's inverter product model

Delta's VFD inverters have established extensive brand awareness in industrial automation stores. Each series of products is designed for different operating needs such as torque, loss, overload, overspeed operation, etc., and is adjusted according to the characteristics of different industrial machinery; It can provide customers with a variety of choices, and a wide range of ...

The common sense principle of inverter - Delta inverter The common sense principle of inverter - Delta inverter

The low-voltage fuse cannot be used as an overload maintenance for the motor. It is necessary that the additional voltage of the fuse is greater than or equal to the operating voltage of the distribution line. It is necessary for the additional current of the fuse to be greater than or equal to the additional current of the melt ...

Solution to Delta inverter fault CE1 and CE2 Solution to Delta inverter fault CE1 and CE2

Product range: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ Problem Code: CE1 Problem Description: Communication is abnormal Solution: 1. Communication error: RS-485 Modbus function code may be faulty ...

Use and maintenance of electric motors - Delta motors Use and maintenance of electric motors - Delta motors

The motor can be started after the work is completed before use, and attention should be paid to the investigation of the motor, transmission device, production machinery and line voltage and ammeter, if there is an abnormal phenomenon, it should be stopped immediately, the fault should be identified and swept away, and then it can be closed and started again. When the motor is running, ...

Inverter application for heat dissipation to solve the precautions - Delta Inverter application for heat dissipation to solve the precautions - Delta

The transformer DC resistance tester uses the 32-bit ARM core as the core of processing, controls the whole machine, and automatically completes the functions of self-calibration, current stabilization judgment, data processing, resistance value display, etc., and can measure the DC resistance of various types of transformers and transformers. ...

PLC Peripherals – Delta PLC PLC Peripherals – Delta PLC

Programming equipment: simple programmer, most only accept mnemonic programming, and some can also be programmed graphically (such as Japan's Toshiba EX programmable controller). The cluttered one has a graphical programmer, which can be programmed in the trapezoidal language. Some also have dedicated computers that can be used for other ...

Delta's various PLC series Delta's various PLC series

At present, Delta PLC has ES, EX, EH2, PM, SA, SC, SS, SX, SV and other series. Each series of models has its own characteristics to meet different control requirements. The ES series is cost-effective and can be controlled sequentially. EX ...

Delta's inverter fault warning solution Delta's inverter fault warning solution

Product series: CP/CH/CT/C2000/C200/MS300/MH300/VE/ED/VJ Fault Codes: noCL Fault clarification: The lack of oil is correct Solution: 1. Check the fuel level of the fuel tank 2. Check whether there is any leakage on the oil road.

The key point to pay attention to when choosing a UPS power supply - Delta The key point to pay attention to when choosing a UPS power supply - Delta

(1) About the synchronous switching function. Now, in addition to the off-line UPS power supply with an additional output power of less than 500VA, the off-line UPS power supply with square wave output is still selected for conversion control without mains synchronization function, and all UPS power supplies with an output power of 1KVA and above are performing the conversion operation of mains power supply to inverter power supply.

Delta's inverter power-on debugging method Delta's inverter power-on debugging method

After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.

Comparison of three speed regulation methods for Delta DC motors Comparison of three speed regulation methods for Delta DC motors

There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation. 1. Armature loop string resistance The applied resistor is connected into the armature circuit to achieve the purpose of speed regulation. Speed Direction: Add ...

Inverter encoder role - Delta Inverter encoder role - Delta

In the case of low speed accuracy requirements or small load changes, the inverter can be selected. The U/f control method refers to the method of controlling the frequency and voltage of the inverter. The rotational speed change in this control method is done by changing the set value of the frequency. ...

Features of two-phase electric fan inverter - Delta Features of two-phase electric fan inverter - Delta

With the continuous development of science and technology, there are more and more types of domestic machinery and equipment, and the upgrading of equipment is getting faster and faster. So what are the characteristics of two-phase electric fan inverter and whether it is worth choosing for enterprises. ...

Composition and function of Delta inverter Composition and function of Delta inverter

Delta inverter is a device that converts the power supply (50Hz or 60Hz) into AC power supply of various frequencies to realize the variable speed operation of the motor.

Delta's C2000 inverter has evolved completely Delta's C2000 inverter has evolved completely

For those who are familiar with Delta's automation, they know that Delta's inverters have two main series: "M300" and "C2000". "Compact Inverter M300 Series": This series has been introduced many times before, including MS300 (standard general-purpose type), MH300 (high power ...

Precautions before installation of Delta inverters Precautions before installation of Delta inverters

Delta's inverter should be thoroughly inspected for initial installation or long-term use. The items and methods to check are as follows: 1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dry for 4 hours (60°C) or in ...

Delta's M series inverter communication parameter address problem Delta's M series inverter communication parameter address problem

In Delta's M series inverters, the parameter address 2000H corresponds to abort, start, JOG, and forward, rotation, and change direction. Why is "aborted" at the time of writing the program H01, "start" is H10, "forward" is H12, and "rotation" is H22. ...

Debugging Delta's inverter method Debugging Delta's inverter method

In order to ensure the reliability of production, when Delta's inverter is planned to be equipped with power drive, in addition to meeting the power drive requirements, the remaining torque increases the consumption of active power. When using cost-effective Delta inverters to regulate the speed, if the flow requirements are reduced, by reducing the rotation of the pump or fan...

Detection methods for Delta circuit breakers, AC contactors and frequency converters Detection methods for Delta circuit breakers, AC contactors and frequency converters

1. Circuit breaker A circuit breaker is a device that can be manually or automatically controlled, and is used to control the on/off of the system power supply in the equipment circuit system. When there is a suspicion that there is a defect in the electrical system of the equipment, the primary functional part of the power supply should be checked. Under normal circumstances, when in the ON state, the input input ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top