1. Control mode:

i.e. speed control, torque control, PID control or other methods. After the control method is adopted, static or dynamic identification should generally be carried out according to the control accuracy.

2. Minimum operating frequency:

That is, the minimum speed of the motor. When the motor works at low speeds, the heat dissipation function is poor. If the motor works at low speed for a long time, the electric machine will burn out. And at low speeds, the current in the cable will also increase, which will also cause the cable to heat up.

                               Basic parameter setting of special inverter for wind turbine - Delta

3. Maximum operation frequency:

Generally, the maximum frequency of the inverter is 60 Hz, and some even reach 400 Hz. High frequencies will make the motor work at high speeds. For ordinary motors, their bearings cannot work at too large fixed speeds for a long time. Whether the rotor of the motor can withstand such centrifugal force.

4. Carrier frequency:

The higher the carrier frequency setting, the higher the harmonic component, which is closely related to the cable length, motor heating, cable heating, inverter heating and other factors.

5. Motor parameters:

In setting the relevant parameters, the power, current, voltage, speed, and maximum frequency of the motor can be obtained directly from the motor nameplate.

6. Frequency hopping:

At a certain frequency point, resonance may occur, especially when the whole device is relatively high; When operating the compressor, avoid the surge point of the compressor.

More on that
The reason for the low voltage trip of the inverter - Delta The reason for the low voltage trip of the inverter - Delta

The low voltage of the inverter mainly refers to the low voltage of the central DC circuit, and the reasons for the low voltage of the central DC circuit generally come from two aspects: ​ (1) Low voltage from the input side of the power supply The power supply under normal conditions ...

How to choose Delta's servo motor How to choose Delta's servo motor

When selecting a Delta servo motor, in principle, the selection should be based on the load conditions. There are two types of loads on the motor shaft, namely damping torque and inertial load. Both loads should be calculated correctly and their values should meet the following criteria:   1) When the machine is running with no load, in the whole speed range, Delta ...

Intelligent thermostat adjustment method - Delta Intelligent thermostat adjustment method - Delta

1. Set temperature: Press the SET button to set or view the temperature set point. Press the SET key digital tube character beginning flash, indicating that the appearance has entered the setting state, press the △ key to increase the set value, press the ▽ key to decrease the set value, press and hold the △ key or ▽ key The data will change rapidly, press the SET key again The appearance back ...

The impact of grid quality on the life of the inverter – Delta The impact of grid quality on the life of the inverter – Delta

Inverter is a high-tech product, mainly composed of power electronic equipment and microelectronic equipment. The three-phase communication grid is connected to the input of the frequency converter. The input end of the inverter is a rectifier circuit, and the output end is a frequency conversion circuit. As a result, the voltages and currents on the input and output sides include abundant ...

Installation requirements for inverter energy consumption braking - Delta inverter Installation requirements for inverter energy consumption braking - Delta inverter

(1) The wiring interval between the braking unit and the inverter, as well as between the braking unit and the braking resistor, should be as short as possible (the wire length should be less than 2m), and the wire cross-section should meet the requirements of the braking resistor discharge current. (2) The brake unit is working ...

Problems in the inverter application – Delta inverters Problems in the inverter application – Delta inverters

1. Harmonic problems The equipment that plays the role of switching in the main circuit of the inverter must generate harmonics in the process of turning on and off the circuit. The lower harmonics generally have a greater impact on the motor load and cause torque ripple; The higher harmonics increase the leakage current of the inverter's output cable, making ...

Introduction to the features of Delta's power modules Introduction to the features of Delta's power modules

1) Brief planning. Only one battery module, paired with several discrete components, is able to obtain a battery. 2) Shorten the development cycle. It is generally equipped with a variety of input, output, and battery module options. Users are also able to repeat or cross-stack, combined with modular batteries, to complete multi-channel ...

Advantages and disadvantages of Delta's open-loop and closed-loop control Advantages and disadvantages of Delta's open-loop and closed-loop control

1. Open-loop control There is no reverse connection between the controller and the controlled target, and the control is carried out in one direction. Strengths: Simple, stable and reliable. If the characteristics and parameter values of the components that make up the system are relatively stable, and the external disturbance is small, the open-loop control energy Enough...

The energy-saving principle of inverter - Delta The energy-saving principle of inverter - Delta

In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain surplus when designing and matching power drive. When the motor cannot operate at full load, in addition to reaching the power drive requirements, the residual torque increases ...

How Delta's touch screen works How Delta's touch screen works

Delta's touch screen consists of a contact detection component and a touch screen controller. The contact detection component is installed in front of the display screen to detect the user's contact orientation and is sent back to the touch screen controller; And Delta's touch screen controller's ...

Delta's MZM position drive system is used for precise application of large inertia Delta's MZM position drive system is used for precise application of large inertia

Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end ...

The output of the inverter is not short-connected to the power frequency The output of the inverter is not short-connected to the power frequency

1. To switch the motor of the power frequency, the parking method is set to free parking, and it is important not to park softly 2. Intercept the contactor of the motor from the output end of the inverter, and the control stop button and the inverter parking button are the same composite button, that is, when the inverter is pressed, the inverter parking will be followed by the contactor line.

Delta's inverter power-on debugging method Delta's inverter power-on debugging method

After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.

PLC Peripherals – Delta PLC PLC Peripherals – Delta PLC

Programming equipment: simple programmer, most only accept mnemonic programming, and some can also be programmed graphically (such as Japan's Toshiba EX programmable controller). The cluttered one has a graphical programmer, which can be programmed in the trapezoidal language. Some also have dedicated computers that can be used for other ...

Inverter setting method - Delta Inverter setting method - Delta

The first step is type recognition: acknowledging whether the type of inverter is common to the type of inverter purchased. If not, ask the agent to return the item. Step 2: Shipping Acknowledgement: After opening the package, check whether the inverter is damaged during transportation. If there is damage, let the agent return ...

Method for measuring temperature rise during reducer operation - Delta Method for measuring temperature rise during reducer operation - Delta

The thermometer method and resistance method can be used to measure the temperature rise of each part of the reducer. 1) Thermometer method: This is the easiest way to measure the temperature directly, and it is commonly measured by an alcohol thermometer. When measuring, the thermometer can be placed close to the ...

Whether the inverter needs to be added to the line - Delta Whether the inverter needs to be added to the line - Delta

The role of the "communication input reactor" of the inverter input device is mainly to improve the power factor of the communication power supply on the communication side of the input side; It is useful to eliminate the higher harmonics on the input side to avoid damage to other electrical equipment caused by voltage distortion; Eliminate the three-phase AC power phase ...

EMC Filter Installation Considerations – Delta EMC Filter Installation Considerations – Delta

All electronic equipment (including frequency converters) will generate some high-frequency or low-frequency noise during normal operation, and disturb the peripheral equipment through conduction or radiation. If the right EMC filter can be configured and the correct device method can be used, the disturbance can be reduced to a minimum. ...

Delta's MH300 series technical specifications Delta's MH300 series technical specifications

Outstanding drive characteristics The overload capacity is up to 150% / 60 seconds, 200% / 3 seconds, suitable for constant torque, variable torque, constant power and other loads Support induction motor, permanent magnet synchronous motor, optional PG card for high ...

The inverter sets the characteristic parameters of the motor The inverter sets the characteristic parameters of the motor

1. Parameters to be set for the motor When the inverter (hereafter referred to as the -VFD) is operating in the "vector control" (F0-03=1) mode, it is highly dependent on accurate motor parameters, which is one of the important differences from the "VF controlled" (F0-03=2) mode. In order for the VFD to have outstanding driving ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top