Delta's inverter process setting

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

1. Restore the inverter to factory settings, press the "ENTER" button to enter the parameter setting interface, and press it continuously until it is 00-00 and then stop. Press the number up button to change to 00-02. Press the "ENTER" key again, the panel value will show 0, press the number up key to change it to 9. Press the "ENTER" key, after power-off and restart, the factory value of recovery is successful.

                               Delta's inverter process setting

2. Set the parameters of the inverter, press the "ENTER" key to enter the parameter setting interface, press it continuously until it is stopped after 00-00, press the number up key to change to 00-20, and change the default value to the required value. Press the "MODE" key to switch between the high and low levels of the parameter code.

3. If you adjust from parameter code 02-16 to parameter code 05-02, press the "MODE" button to switch between the high and low positions of the parameter code, and you can first adjust 02 to 05, and then adjust 16 to 02.

4. Note: (1) Power off is required for each rehabilitation factory setting and parameter setting; (2) Start the inverter on the host computer for testing, the panel working indicator light is on, and the motor work means that the setting is successful, otherwise the parameters will be recognized from the beginning.

More on that
Brand inverter modifies the power method - Delta Brand inverter modifies the power method - Delta

What are the benefits of inverter power correction? Many brands of inverter power boards, driver boards, and motherboards can be universal, as long as the type, volume, and hardware are the same, and the desired power and voltage value can be obtained by correcting the manufacturer's parameters.

How to choose the right Delta inverter for the motor How to choose the right Delta inverter for the motor

Delta's inverter has made the motor drive system complete two hopes: first, the motor has completed the operation of higher power; The second is to make the motor controllable and prevent the problem of the big cow pulling the trolley. But the problem in front of the engineer is: there are so many types of motor loads, and the frequency converter ...

TIMTOS x TMTS 2022 - Delta's Exhibit Highlights TIMTOS x TMTS 2022 - Delta's Exhibit Highlights

Intelligent machining solution plan Intelligent machinery is an important step towards intelligent manufacturing, in order to help manufacturers improve productivity or complete a few diverse forms of production, Delta will exhibit the intelligent processing solution plan at TIMTOS x TMTS 2022, which will be used to communicate with industrial-grade managed Ethernet networking.

Delta-B series inverter inverter output module is damaged and the drive circuit is damaged Delta-B series inverter inverter output module is damaged and the drive circuit is damaged

Delta-B series inverter inverter output module is damaged and the drive circuit is seriously damaged: the drive integrated circuit T250V or burst, or the output terminal and the power supply ground are short-circuited, the filter capacitor is sprayed, the regulator tube is broken down or open, the resistance is open or the resistance value increases, and the circuit board carbonization is damaged.

Delta's PLC programmable controller product list Delta's PLC programmable controller product list

1. Programmable manipulator AH series Delta's AH series modular controllers provide automation system solutions for high-end applications. The AH series adopts a comprehensive modular design, and on the basis of Delta's research and development skills, it has developed ...

Inverter setting method - Delta Inverter setting method - Delta

The first step is type recognition: acknowledging whether the type of inverter is common to the type of inverter purchased. If not, ask the agent to return the item. Step 2: Shipping Acknowledgement: After opening the package, check whether the inverter is damaged during transportation. If there is damage, let the agent return ...

Delta's power supply series application considerations Delta's power supply series application considerations

(1) Considering that the power supply is inconsistent at the time of power-on, the load is short-circuited, and the rational load may present a reverse voltage, the output end of each power supply connected in series should be set up with two anti-parallel tubes, and the forward additional current of the two * tubes should not be less than the additional output current of the power supply, and the reverse breakdown voltage should not be less than ...

Debugging Delta's inverter method Debugging Delta's inverter method

In order to ensure the reliability of production, when Delta's inverter is planned to be equipped with power drive, in addition to meeting the power drive requirements, the remaining torque increases the consumption of active power. When using cost-effective Delta inverters to regulate the speed, if the flow requirements are reduced, by reducing the rotation of the pump or fan...

Delta inverter fault alarm code and solution Delta inverter fault alarm code and solution

The OCC AC motor driver detects an unusual overcurrent surge on the output side See if the motor extra matches the communication motor drive extra Check whether there is a short circuit between the communication motor driver U-V-W View...

Introduction to the inverter selection strategy - Delta inverter Introduction to the inverter selection strategy - Delta inverter

1. Ability to adapt to the environment 1.1 Ability to adapt to grid voltage fluctuations When the motor on the bus starts in a group, when the largest motor unit on the bus starts, the influence on the operation of the inverter, which is related to the input voltage fluctuation range parameters promised by the inverter.

Delta inverter parameter replication error solved Delta inverter parameter replication error solved

1. SE2 parameter imitation error Problem Description: Keypad Imitation Function Fault Correction 2 Solution: 1. The Keypad imitation action is completed, and the inverter parameters are written into error 2. SE1 Parameter Imitation ...

Inverter acceleration and deceleration mode selection - Delta Inverter acceleration and deceleration mode selection - Delta

Inverter acceleration form and deceleration form selection, also known as acceleration and deceleration curve selection. Generally, there are several forms of inverter, such as linear, S-shaped, semi-S-shaped, etc., and the characteristics and uses of each form are as follows: 1. Linear form This form makes the inverter's ...

Inverter encoder role - Delta Inverter encoder role - Delta

In the case of low speed accuracy requirements or small load changes, the inverter can be selected. The U/f control method refers to the method of controlling the frequency and voltage of the inverter. The rotational speed change in this control method is done by changing the set value of the frequency. ...

The importance of harmonic control - Delta inverter The importance of harmonic control - Delta inverter

With the rapid development of the electronic and electrical industries, the demand for magnetic materials has promoted the world's huge industrial clusters. In the process of producing magnetic materials, many manufacturers are facing a great dilemma: the production of magnetic materials is mainly controlled by thyristor rectifier furnaces such as bell furnaces and nitrogen rotary furnaces.

The power frequency motor is not normally installed with the inverter hazard The power frequency motor is not normally installed with the inverter hazard

Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the efficiency and accuracy of the motor. However, if not properly equipped and used, it may cause the following hazards: ...

The difference between a general-purpose inverter and a vector inverter - Delta The difference between a general-purpose inverter and a vector inverter - Delta

There are two main differences between vector inverter and general inverter, the first is high control accuracy, and the other is high output torque at low speed. It can output 150%-200% of the rated torque. It should be vector frequency conversion is to decompose the motor current into D-axis current and Q-axis current, where D-axis current is excitation current ...

Inverter wiring and parameter setting method - Delta Inverter wiring and parameter setting method - Delta

The inverter used in industry is divided into two types: single-phase and three-phase, which is distinguished from the voltage supplied by the main circuit, which is the main circuit to be connected to RST three-phase 380 volt alternating current, and the output is connected to the UVW three-phase line to the motor; And the single-phase is the main circuit connected to the single-phase 220 volt LN alternating current, the output is the same ...

Characteristics of common models of Delta inverters Characteristics of common models of Delta inverters

Delta MS300 Inverter Series: Delta's compact standard vector-operated inverter MS300 combines the advantages of miniaturization, high functionality, high trust, and simple installation, transforming every investment in industrial resources into abundant results. Optimized structure with lock-free screw terminals to plan the supply of bento ...

Introduction to common models and parameters of Delta touch screens Introduction to common models and parameters of Delta touch screens

There are many types of Delta contact screens, of course, the parameters of different types are different, and the most important product is DOP-B03S201. This product is a 4.3-inch screen, its aspect ratio is 16:9, the screen is made of TFT raw materials, and its resolution can reach 480X ...

The parameter that needs to be set for the inverter - Delta The parameter that needs to be set for the inverter - Delta

There will be some difference between the parameter setting of the inverter at the factory and the requirements of practical application. Therefore, the reasonable setting of the inverter parameters is directly related to whether the inverter can be used normally, which is of decisive significance. General-purpose inverters generally have dozens or even hundreds of functional parameters.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top