Delta's MZM position drive system is used for precise application of large inertia

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Driven by consumption promotion and product diversification, the manufacturing industry's demand for automation and intelligent promotion in production and processing is also increasing. In the production process, the processing of "large and heavy" items is often difficult to control accurately, and the error of orientation is not as easy as that of "small" items. To this end, Delta has recently officially launched the MZM, a high-power azimuth drive system for shopping malls, which combines the characteristics of high power and precise positioning, and can meet the needs of precise positioning in the power scale of 15-80 kW, and then break through the constraints of high-power azimuth drive shopping malls.

                                 Delta's MZM position drive system is used for precise application of large inertia

Shi Wenxiang, product director of Delta-Zhongda Dentsu inverter, said that most of the directional drive demand in the industrial field is concentrated in the small power scale, and the shopping mall often thinks that it is difficult to achieve both high power and accurate control. Conventional inverters can complete hundreds of kW of high power, and the bandwidth is fundamentally lower than 40 Hz, which is not accurate; The general servo has a bandwidth of 1-3K, and it is no problem to complete accurate control at low power, but it is difficult to adhere to the stability of the function when the power gradually increases. With the expansion of automation work, Delta has also seen some shopping malls that have practical use needs, such as punch punching and flying saw equipment for building materials, centrifuges and CT instruments for medical applications, and large-scale stage lifting equipment, which often require drive control plans with sufficient power and accurate control. Delta's MZM high-power azimuth drive system came into being, which has the characteristics of both high power and precise positioning, and is a powerful tool for high-power azimuth drive.

Delta's MZM high-power azimuth drive system integrates the functions of Delta's heavy-duty vector control inverter CH2000 series, high-power servo motors, bus cards, and motion control cards. The MZM high-power azimuth drive system is concentrated in the power scale of 15-80 kW and can achieve an output torque of 48-520 N. The accuracy of 1500 RPM and 17 bit is enough to complete the needs of accurate control. For the use of fixed-length and fixed-distance motion control of punching machines, flying saws, conveyors, winding machines, forming machines, etc., Delta's high power and accurate control not only fully match the needs of the scene, but also present it in the form of a complete drive system, ensuring the stability of the system from the source, and then giving customers a greater competitive advantage.

The motor control center algorithm carefully developed by Delta is the key to the success of MZM's high-power azimuth drive system. MZM supports CSP, CST, CSV, HM and other forms, which can meet the needs of various sports forms; The product also has the function of ASR gain self-adjustment, which makes the control process more refined and smooth under the exquisite control of the central algorithm. Even at low frequencies, torque shake control is guaranteed to be within ±1.6%. Taking the centrifuge in the medical profession as an example, this use not only has a large load and high control accuracy, but also has a strict constraint on the torque fluctuation of the system. Delta's MZM system, on the other hand, can complete the positioning accuracy of a pulse while running stably, and the speed fluctuation during positioning does not exceed 1 RPM.

Similarly, in use scenarios that require more fine control, such as CT machines, large-scale analyzers, and rotary table grinders, Delta's MZM also has weak competitiveness.

User-friendly operation and easy to use for commissioning

Taking into account the convenience of device commissioning, MZM is able to directly identify the matching motor type and automatically obtain its parameters and optimal control strategy. Without the need for human intervention, the characteristics of the motor can be fully utilized.

The MZM is also equipped with special engineering assistance software, which makes the system adjustment, diagnosis, and monitoring intuitively visible. The commissioning of the equipment can be completed quickly, which will save customers more time and benefits.

Occupation uses function modules to improve the ease of use of products

For typical use scenarios of target occupations, such as punch manufacturing process, steel plate manufacturing process, etc., Delta has also developed corresponding special function modules for MZM, which can be used for positioning control, fixed length and fixed distance, etc., greatly shortening the equipment development time, and improving the ease of use of the product through the modular feature of function blocks.

High degree of integration Easily build an integrated plan

Combined with Delta's PC-Based Motion Controller AX series, multi-axis motion controller DVP-MC series, human-machine interface, and integrated programming software, the product can easily build a complete set of system solution plans to ensure system compatibility and stability.
More on that
Tips and methods for using PLC - Delta PLC Tips and methods for using PLC - Delta PLC

First, the selection of output module The output modules are divided into transistors, triacs, and contact types: (1) The switching speed of the transistor type is fast (generally 0.2ms), but the load can be small, about 0.2-0.3A, 24VDC, suitable for fast switching, signal contact...

Factors affecting Delta's inverter motors and countermeasures Factors affecting Delta's inverter motors and countermeasures

1. The influence of leakage current on the motor and countermeasures If the wiring length is very long, the stray capacitance between the wires will increase, resulting in leakage current. It will initiate overcurrent maintenance, increase leakage current or not ensure the correctness of the current display. The bad situation is that the inverter will ...

Cause of Servo Motor Failure – Delta Cause of Servo Motor Failure – Delta

1. The motor is broken shaft 1. The cause of the problem (1) Unreasonable mechanical design leads to excessive radial load force; (2) The load end is stuck or severely overloaded; (3) The motor and reducer are not centered when installed. 2. Eliminate problems (1) Check the ...

Precautions for long-term idle inverter - Delta inverter Precautions for long-term idle inverter - Delta inverter

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems: ...

The benefits of using an inverter – Delta inverter The benefits of using an inverter – Delta inverter

1. Speed regulation of general motor: By changing the input voltage and frequency of the three-phase asynchronous motor, its speed can be controlled. Generally, when the motor is at low speed, the temperature rise becomes larger due to the decrease in the power of the cooling fan, and the motor load should be reduced according to the frequency. 2 ...

Precautions for summer maintenance and maintenance of inverters - Delta Precautions for summer maintenance and maintenance of inverters - Delta

1. Check the operating status of the inverter, whether the voltage and current value during operation are within the normal range. 2. Carefully monitor and record the ambient temperature of the frequency conversion room, and the ambient temperature is generally between -10 °C and 40 °C. The temperature rise of the phase-shifting transformer should not exceed 130°C. 3. Avoid ...

Delta's inverter and output reactor function Delta's inverter and output reactor function

input/output reactor for frequency conversion speed regulation; Because the inverter is often affected by the impact of inrush current and surge voltage in the process of driving the inverter motor operation governor, which will seriously damage the function and service life of the inverter and the motor, so it is necessary to install a transmission system in front of it.

The inverter has a function – a Delta inverter The inverter has a function – a Delta inverter

1. Soft start is energy-saving The hard start of the motor will cause a serious impact on the power grid, and it will also require too high the capacity of the power grid, and the large current generated when the motor is started and the sensation will cause great damage to the baffle and valve, and the service life of the equipment and pipeline will be extremely unlucky. And the use of inverter energy-saving devices ...

Delta's active front-end and inverter's coordination Delta's active front-end and inverter's coordination

The popularity of frequency converters has brought significant energy savings to industrial applications. However, the high-frequency switching signal generated by the inverter is easy to cause electromagnetic interference and affect the power quality. Especially in industries with large loads such as lifting and elevators, it is becoming more and more obvious. ...

New and old models of Delta drives New and old models of Delta drives

Delta's VFD series of inverters has established a wide brand awareness in the industrial automation market. Each series of products is designed for different operation needs such as torque, loss, overload, overspeed work, etc., and is adjusted according to different industrial machinery attributes; It can provide customers with the most diversified choices ...

Advantages and disadvantages of Delta's open-loop and closed-loop control Advantages and disadvantages of Delta's open-loop and closed-loop control

1. Open-loop control There is no reverse connection between the controller and the controlled target, and the control is carried out in one direction. Strengths: Simple, stable and reliable. If the characteristics and parameter values of the components that make up the system are relatively stable, and the external disturbance is small, the open-loop control energy Enough...

Inverter setting method - Delta Inverter setting method - Delta

The first step is type recognition: acknowledging whether the type of inverter is common to the type of inverter purchased. If not, ask the agent to return the item. Step 2: Shipping Acknowledgement: After opening the package, check whether the inverter is damaged during transportation. If there is damage, let the agent return ...

The impact of inverters on motors – Delta inverters The impact of inverters on motors – Delta inverters

1. Overvoltage The output of the inverter has the function of voltage detection, and the inverter can actively adjust the output voltage so that the motor does not withstand overvoltage. Even when the output voltage adjustment fails and the output voltage exceeds 110% of the normal voltage, the inverter will be shut down and the motor will become infected. ...

Delta's N 1-3kVA series has three core advantages Delta's N 1-3kVA series has three core advantages

In addition to adhering to the high reliability, excellent efficiency and outstanding power of Delta's UPS products, the N1-3kVA series has three obvious core advantages: 1. High availability planning Delta N 1-3kVA series ...

Inverter Fault Repair Test Method - Delta Inverter Fault Repair Test Method - Delta

Static quizzes 1. Test the rectifier circuit Find the P and N ends of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, connect the red watch rod to P, and separate the black watch rod to R, S, T. Instead, connect the black watch rod to the P...

Delta's touch screen controls the inverter method Delta's touch screen controls the inverter method

1. The touch screen is controlled by PLC inverter 1. Now the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

The parameter that needs to be set for the inverter - Delta The parameter that needs to be set for the inverter - Delta

There will be some difference between the parameter setting of the inverter at the factory and the requirements of practical application. Therefore, the reasonable setting of the inverter parameters is directly related to whether the inverter can be used normally, which is of decisive significance. General-purpose inverters generally have dozens or even hundreds of functional parameters.

Several veins of the inverter circuit - Delta inverter Several veins of the inverter circuit - Delta inverter

1. Vibration circuit: the leakage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels of the power supply operation current; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

Touch screen controls the inverter step – Delta Touch screen controls the inverter step – Delta

1. The touch screen is controlled by PLC inverter 1. At present, the general control of the inverter needs to choose PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

Delta inverter parameter replication error solved Delta inverter parameter replication error solved

1. SE2 parameter imitation error Problem Description: Keypad Imitation Function Fault Correction 2 Solution: 1. The Keypad imitation action is completed, and the inverter parameters are written into error 2. SE1 Parameter Imitation ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top