Precautions for the use of Delta inverter MS300 series

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Before operating the MS300 series products, please read and pay attention to the relevant safety information to ensure your own safety and product safety.

When operating the wiring and installing the inverter, it is necessary to confirm that the power supply is closed.

After the communication power supply is blocked, the POWER indicator of the inverter (located behind the digital operator) is not calmed down, indicating that there is still high voltage inside the inverter, do not touch the internal circuits and components.

                              Precautions for the use of Delta inverter MS300 series

The circuit components on the internal circuit board of the inverter are susceptible to damage by static electricity, so do not touch the circuit board with your hands before the anti-static measures are taken.

Do not modify the internal parts or wiring of the inverter by yourself.

It is necessary that the drive terminals are properly grounded in accordance with local regulations.

In the case of inverter and accessories, it should be kept away from fire sources, heating elements and flammable materials.

Do not input the AC power supply to the output terminals U/T1, V/T2, and W/T3 of the inverter.

The additional voltage of the power supply system installed by the inverter is as follows, please do not exceed this applicable scale:

The scale of change of 1.115V series models is 85V - 132V.

2. The scale of change of 230V series models is 170V - 264V.

3. The scale of change of 460V series models is 323V-528V.

The scale of change of 4.575V series models is 425V-660V.

Please refer to the following table for short-circuit current capacity:

Series model (power) short-circuit current capacity

  115V                       5kA

  230V                       5kA

  460V                       5kA

  575V                       5kA

Only qualified motor professionals are required to install, wiring and repair the inverter.

Even if the three-phase communication motor is aborted, the main circuit terminals of the inverter may still carry dangerous high voltages.

If an electrolytic capacitor is left unpowered for a long time, its function will be reduced. Therefore, it is necessary to energize the inverter for about 3-4 hours every 2 years (note) to restore the function of the electrolytic capacitor inside the inverter.

Note: When the inverter is powered, it is necessary to use an adjustable AC power supply (such as AC autotransformer) to power on at an additional voltage of 70-80% for 30 minutes (do not run), and then power on with an additional voltage for 1 hour (do not run), so that the function of the electrolytic capacitor inside the inverter can be restored, and then start to run the inverter, and the power cannot be directly transmitted to the additional voltage.

Precautions for insect removal treatment of outer box packaging (including wooden boxes, wooden strips, etc.) during transportation and installation:

1. If the wooden packaging materials used for packaging need to be dewormed, the use of fumigation methods should be prohibited, and if the machine is damaged as a result, it will not be included in the warranty scale.

2. Please choose other methods, such as wood box heat treatment or other non-fumigation methods for pest removal operations.

3. When using the high temperature method of heat treatment of wooden box: the packaging material can be kept in an environment with a temperature of more than 56 °C for more than 30 minutes.

Please connect the three-phase 3-wire Y-connected power system or the three-phase 4-wire Y-connected power system to meet UL standards.

If the leakage current of the inverter exceeds the communication of 3.5mA or 10mA DC on the protective grounding conductor, the small specifications of the selected protective grounding conductor shall conform to the local national regulations or be grounded according to IEC61800-5-1.

More on that
VFD center power electronics and control mode VFD center power electronics and control mode

1) Power electronic equipment power electronic equipment is in the circuit to play the effect of on-off and complete a variety of converter equipment, VFD is the installation of this converter, so it is with the development of the inverter equipment and unfold, the quality of the inverter equipment depends on its on-off ability, accept the on-off current and amount...

How to choose Delta's servo motor How to choose Delta's servo motor

When selecting a Delta servo motor, in principle, the selection should be based on the load conditions. There are two types of loads on the motor shaft, namely damping torque and inertial load. Both loads should be calculated correctly and their values should meet the following criteria:   1) When the machine is running with no load, in the whole speed range, Delta ...

Several veins of the inverter circuit - Delta inverter Several veins of the inverter circuit - Delta inverter

1. Vibration circuit: the leakage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels of the power supply operation current; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

The principle structure of low-voltage circuit breaker - Delta The principle structure of low-voltage circuit breaker - Delta

Low-voltage circuit breakers, commonly known as active air switches, are one of the primary electrical switches in low-voltage distribution networks. It can not only turn on and off normal load current, motor operation current and overload current, but also turn on and off short circuit current. It is mainly used as a low-voltage distribution line or a switch cabinet that is not often operated ( ...

DC governor overhaul method - Delta DC governor overhaul method - Delta

DC governor is a kind of motor speed regulation equipment, including motor DC governor, pulse width DC governor, thyristor DC governor, etc. Generally, it is a modular DC motor governor, which integrates power supply, control and drive circuits, selects three-dimensional structure layout, and selects micro-power consumption elements for control circuits.

Inverter setting method - Delta Inverter setting method - Delta

The first step is type recognition: acknowledging whether the type of inverter is common to the type of inverter purchased. If not, ask the agent to return the item. Step 2: Shipping Acknowledgement: After opening the package, check whether the inverter is damaged during transportation. If there is damage, let the agent return ...

Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines Delta's Amplon N series UPS ensures the safety of electricity consumption in pharmaceutical production lines

In recent years, in response to the development trend of automation, informatization and intelligence, pharmaceutical companies have continuously innovated, transformed and upgraded, selected fully automated intelligent production lines, accelerated the upgrading of equipment in the pharmaceutical industry, and completed the use of smart pharmaceutical technology for green, safe, high-quality and low-consumption development in the pharmaceutical industry.

Cause of Servo Motor Failure – Delta Cause of Servo Motor Failure – Delta

1. The motor is broken shaft 1. The cause of the problem (1) Unreasonable mechanical design leads to excessive radial load force; (2) The load end is stuck or severely overloaded; (3) The motor and reducer are not centered when installed. 2. Eliminate problems (1) Check the ...

Delta's inverter is automatically changed to manual setting Delta's inverter is automatically changed to manual setting

The converter is capable of manual and active switching: 1. The switching between the manual operating system and the DCS operating system is done by the transfer switch SA installed on the field operation tower, which has active, manual and ...

Delta's Smart series of micro-modules help transform high-speed tunnel networks Delta's Smart series of micro-modules help transform high-speed tunnel networks

Recently, Delta's Smart series of micro-modular data center processing solutions successfully assisted the smooth implementation of a provincial tunnel network transformation project in a province. The project has set up a series of safety operation networks such as video, lights, signals, networks, rescues, and alarms for the safe operation of key roads in the province.

Installation steps of motor protector – Delta Installation steps of motor protector – Delta

1. According to the requirements of the device parts, the method and the maintenance function are required, and the type of motor maintainer and its various maintenance action parameter settings are reasonably selected; 2. According to the requirements of the product instruction manual, the correct device should be connected correctly according to the purpose of each terminal, and the working power supply should be connected to the control ...

The output of the inverter is not short-connected to the power frequency The output of the inverter is not short-connected to the power frequency

1. To switch the motor of the power frequency, the parking method is set to free parking, and it is important not to park softly 2. Intercept the contactor of the motor from the output end of the inverter, and the control stop button and the inverter parking button are the same composite button, that is, when the inverter is pressed, the inverter parking will be followed by the contactor line.

Precautions for long-term idle inverter - Delta inverter Precautions for long-term idle inverter - Delta inverter

If the inverter is to run the equipment again after being shelved for more than half a year, the probability of damage may be greatly increased due to many factors such as the placement environment, the service life of the inverter, and the load rate, and the failure usually presents the following problems: ...

Do Delta thermostats have a "slope control" function? Do Delta thermostats have a "slope control" function?

Delta's thermostats are only available in the DTE series (variety 1.5 and above) with the "slope control" function. Illustrate the following examples: For example: PV=20°C, SV=100°C, slope 10.0°C/min Then (100 – 20)/10.0 ...

Precautions for inverter selection - Delta Precautions for inverter selection - Delta

The selection of the inverter is mainly determined by the load characteristics of the drive and the actual working current of the motor, in addition to the following precautions: 1. The environment is suitable for some high temperature (higher than 50 degrees) and high altitude (higher than 1000 meters).

Delta's inverter failure analysis Delta's inverter failure analysis

1. Fault code: SE1 parameter replication error Fault Description: Keypad replication function error correct Solution: Keypad replication action errors, including communication delays, communication errors (Keypad received FF86 errors), and parameter value errors ...

Precautions before installation of Delta inverters Precautions before installation of Delta inverters

Delta's inverter should be thoroughly inspected for initial installation or long-term use. The items and methods to check are as follows: 1) Check whether the Delta inverter is damaged, whether the metal parts are rusty, and whether there is frost. If there is frost and condensation, it should be dry for 4 hours (60°C) or in ...

Delta's servo protection parameters are written Delta's servo protection parameters are written

A3, B3 servo P5-97 Motion Control Mobilization Commands 0x0003 Maintenance Activation (Successful Return 0x1003) 0x0004 Maintenance Waiver (Successful Return 0x1004) If the wrong cipher code is entered, the error code Ennn will be sent back to exempt the loss, during which nnn indicates that there is a ...

Analysis of misunderstandings in the application of Delta inverters Analysis of misunderstandings in the application of Delta inverters

The capacity selection of the inverter is based on the rated power of the motor Myth: The capacity selection of the inverter is based on the rated power of the motor Compared with the motor, the price of the frequency converter is the most expensive, so under the premise of ensuring safe and reliable operation, the frequency conversion can be reasonably reduced.

PLC Peripherals – Delta PLC PLC Peripherals – Delta PLC

Programming equipment: simple programmer, most only accept mnemonic programming, and some can also be programmed graphically (such as Japan's Toshiba EX programmable controller). The cluttered one has a graphical programmer, which can be programmed in the trapezoidal language. Some also have dedicated computers that can be used for other ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top