A3, B3 servo
P5-97 Motion Control Mobilization Commands
0x0003 Maintenance Activation (Successful Return 0x1003)
0x0004 Maintenance Waiver (Successful Return 0x1004)
If the wrong code is entered, it will be sent back to the exempt error code Ennn, during which nnn indicates the number of times that can be tested and decoded, each time it fails, this number is reduced by one, when this number is reduced to 0, it means that the number of input code errors exceeds the number of times, and it will be permanently locked.
P5-93 Parameter Write Maintenance Level
0 No maintenance
1 Start maintenance
P5-94 Data Array Maintenance Level
-1. Parameter groups (P5, P6, P7) can be read as well as arrays of material array columns
Neither the parameter groups (P5, P6, P7) nor the material array array can be read
Parameter groups (P5, P6, P7) and material array array #100 - #799均可读取
Parameter groups (P5, P6, P7) and material array array #200 – #799均可读取
Parameter groups (P5, P6, P7) and material array array #300 - #799均可读取
Parameter groups (P5, P6, P7) and material array array #400 – #799均可读取
Parameter groups (P5, P6, P7) and material array array #500 - #799均可读取
Parameter groups (P5, P6, P7) and material array array #600 – #799均可读取
Parameter groups (P5, P6, P7) are not readable, but material arrays can be read
P5-95 Set a new cipher (1-16777215)
P5-96 Acknowledging the New Code (1-16777215)
B2 servo
P2-08 PCTL Special Parameter Write
User parameter write-maintenance code settings:
After pressing the 5-digit number, then press the same password to acknowledge, that is, the end of the setting (*** The high digit is at least 1)
After turning on the power from scratch, the code maintenance is effective.
Parameters set for the code:
Once the correct cipher code is set, the parameters can be set
Cipher Elimination:
After setting the correct code, enter "0" twice in a row.
A2 servo
P5-97 Motion Control Mobilization Commands
0x0003 Maintenance Activation (Successful Return 0x1003)
0x0004 Maintenance Waiver (Successful Return 0x1004)
If the wrong code is entered, it will be sent back to the exempt error code Ennn, during which nnn indicates the number of times that can be tested and decoded, each time it fails, this number is reduced by one, when this number is reduced to 0, it means that the number of input code errors exceeds the number of times, and it will be permanently locked.
P5-93 Parameter Write Maintenance Level
0 No maintenance
1 Start maintenance
P5-94 Data Array Maintenance Level
The cipher maintains the size of the full data array
Code maintenance data array size #100-#799
Code maintenance data array size #200-#799
Code maintenance data array size #300-#799
Code maintenance data array size #400-#799
Code maintenance data array size #500-#799
Code maintenance data array size #600-#799
None of them are maintained
P5-95 Set a new cipher (1-16777215)
P5-96 Acknowledging the New Code (1-16777215)
|
More on that
|
Delta UPS uninterruptible power supply R-2K series
With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.
|
|
The frequency of the inverter is given in a given way - Delta
The main way to use the inverter is to change the output frequency to achieve the controllability of the motor speed, so do you know what steps are required to complete the output frequency controllability? One of the main points is how to complete the change of the frequency signal supplied by the inverter equipment.
|
|
Debugging method of Delta servo motor
1. Initialize parameters
Before wiring, initialize the parameters.
On the control card: select the control method; Reset the PID parameter to zero; When the control card is powered on, the enable signal is closed by acquiescence; Save this condition to make sure that the control card ...
|
|
The output of the inverter is not short-connected to the power frequency
1. To switch the motor of the power frequency, the parking method is set to free parking, and it is important not to park softly
2. Intercept the contactor of the motor from the output end of the inverter, and the control stop button and the inverter parking button are the same composite button, that is, when the inverter is pressed, the inverter parking will be followed by the contactor line.
|
|
Inverter performance test method - Delta
As we all know, the inverter has many maintenance functions, such as overcurrent, overvoltage, overload maintenance and so on. With the continuous improvement of industrial automation, frequency converters have also been widely used. This article will explain to you how to use a multimeter to measure the quality of the inverter.
Need...
|
|
Delta's various PLC series
At present, Delta PLC has ES, EX, EH2, PM, SA, SC, SS, SX, SV and other series. Each series of models has its own characteristics to meet different control requirements.
The ES series is cost-effective and can be controlled sequentially.
EX ...
|
|
Delta's powerful NT series industrial-grade UPS
Delta's NT series industrial-grade UPS has always been an ideal choice for applications that require high power safety due to their high reliability and high-density planning. IGBT high-frequency switching sinusoidal pulse width modulation technology planning, which makes UPS have good power supply quality, high efficiency, low heat loss, noise ...
|
|
Methods for preventing and controlling high-current contactor contact heat - Delta
The key to dealing with the heat of the high-current toucher is to make the contact tightly connected to the copper braid so that it does not loosen. Useful methods of prevention and control are as follows:
(1) The copper braid and the moving contact touch are made with a mixture of 60% tin and 40% lead.
|
|
Post-inverter shutdown maintenance project – Delta
1. Use a vacuum cleaner with a plastic nozzle to completely clean the inside and outside of the inverter cabinet to ensure that there is no excessive dust around the equipment.
2. Check the ventilation and lighting of the inverter room, and the ventilation equipment can work normally.
3. Check the inverter ...
|
|
Ways to reduce the failure rate of Delta drives
If you want to reduce the fault rate of Delta inverter, it is necessary to check it daily, and what are the detailed items?
Delta inverter fault repair ...
|
|
Delta's high-performance servo ASDA-A3 series is a new product
With the rapid development of automation technology and shopping malls, customers have higher and higher requirements for the speed, accuracy and function diversification of servo products. In order to get used to the needs of shopping malls, recently, Delta launched the high-performance motion control high-end AC servo system ASDA-A3 series ...
|
|
Delta inverter password
The inverter of Delta's brand A series locks the keypad to correct the parameters, forming that most of the parameters cannot be corrected, and the manual does not clearly explain how to unlock the keypad lock, press MODE and RESET together to display P256 (P256 does not explain what it means in the manual), press ENTER...
|
|
Delta servo system composition
The servo system is mainly composed of a servo controller, a drive circuit, a servo motor and the corresponding reaction testing equipment.
(1) Servo motor
Servo motor refers to the motor that controls the mechanical components in the servo system, and the servo motor has an encoder inside, which can respond to the movement in real time.
|
|
Delta's SCARA industrial robots help replace machines in the electronics manufacturing industry
Project Background
At present, electronic products such as mobile phones, computers, and IPads have become the standard in people's lives, which also promotes the rapid development of the electronic manufacturing industry. PCB (printed circuit board) is an important component in electronic products, with the trend of electronic products towards high-end, miniaturization ...
|
|
Delta launched an integrated control solution for layer winding
As factories move from automation to intelligence, the requirements for equipment performance and scalability are progressing day by day. In response to the rapid development of electronic engineering, transportation and mechanical engineering and other occupations, in order to quickly manufacture related product parts and components, metal coil winding technology is also being carried out at a high speed.
|
|
Whether the inverter needs to be added to the line - Delta
The role of the "communication input reactor" of the inverter input device is mainly to improve the power factor of the communication power supply on the communication side of the input side; It is useful to eliminate the higher harmonics on the input side to avoid damage to other electrical equipment caused by voltage distortion; Eliminate the three-phase AC power phase ...
|
|
The power frequency motor is not normally installed with the inverter hazard
Installing a variable-frequency drive (VFD) on the power frequency motor can complete the accurate control and speed regulation of the motor, and improve the efficiency and accuracy of the motor. However, if not properly equipped and used, it may cause the following hazards:
...
|
|
VFD center power electronics and control mode
1) Power electronic equipment power electronic equipment is in the circuit to play the effect of on-off and complete a variety of converter equipment, VFD is the installation of this converter, so it is with the development of the inverter equipment and unfold, the quality of the inverter equipment depends on its on-off ability, accept the on-off current and amount...
|
|
Inverter maintenance is easy to ignore the problem - Delta
1. After the inverter is repaired, the power number needs to be corrected, don't forget it
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Delta's inverter energy-saving method
Delta's inverter energy-saving method is mainly manifested in the application of fans, pumps, and hoists. In order to ensure the reliability of production, all kinds of production machinery are designed with power drive, and there is a certain amount of surplus.
Power Factor Supplement ...
|
|