Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to complete the variable speed operation of the motor, in which the control circuit completes the control of the main circuit, the rectifier circuit converts the communication power into direct current, the DC center circuit filters the output of the rectifier circuit, and the inverter circuit reverses the direct current into communication electricity.
In addition to speed regulation and soft start effect, the most important thing is to be able to save energy.
The composition of Delta's inverter
The inverter is generally divided into 4 parts: the rectifier unit, the high-capacity capacitor, the inverter and the controller.
Rectifier unit: converts the communication power with a fixed operating frequency into direct current.
High Capacitance: Stores converted electrical energy.
Inverter: An electronic switch composed of an array of high-power switching transistors, which converts direct current into square waves of different frequencies, widths, and fluctuations.
Controller: Operate according to the set program, control the fluctuation and pulse width of the output square wave, make the communication electricity superimposed as an approximate sine wave, and drive the communication motor.
The functional effect of the inverter
The energy saving of the inverter is mainly manifested in the application of fans and pumps. In order to ensure the reliability of production, all kinds of production machinery have a certain surplus when planning to use power drive. When the motor cannot run at full load, in addition to meeting the requirements of power drive, the excess torque increases the consumption of active power and forms the waste of electric energy. The traditional speed regulation method of fans, pumps and other equipment is to regulate the air volume and water supply by adjusting the baffle plate and valve opening of the inlet or outlet, and the input power is large, and a large amount of energy is consumed in the interception process of the baffle and valve. When using variable frequency speed regulation, if the flow requirement is reduced, the speed of the pump or fan can be lowered to meet the requirements.
|
More on that
|
Delta's B2 series servo motor parameter setting
Automatic:
P0-02 Drive Status Display Parameter Function: 07Motor Speed (r/min)
P1-01 Control form and control command input source setting parameter function: 02 Select S form (r/min)
P1-38: Zero speed detection accuracy (no response below set speed)
P1-4 ...
|
|
The impact of Delta's inrush current on the inverter
In the process of repairing the inverter, it is found that because of the back electromotive force in the stator winding, the electromotive force in the synchronous generator state and the self-induced electromotive force in the self-induced rotor, the current impact must have a negative impact on the motor, the inverter (Variable-frequency Drive, ...
|
|
Mitsubishi's MHIET energy storage system, Delta, helped to solve the problem
Battery Management Solution Factory - Delta released the Mitsubishi Heavy Industries Group's star product, Mitsubishi Heavy Industries Group's three-power transformer hybrid one-power transformer system, proposing a high-quality method. This power transformer system is currently used at Mitsubishi Electric Manufacturing Plant in Aihara City, Kanagawa Prefecture, Japan.
|
|
The impact of grid quality on the life of the inverter – Delta
Inverter is a high-tech product, mainly composed of power electronic equipment and microelectronic equipment. The three-phase communication grid is connected to the input of the frequency converter. The input end of the inverter is a rectifier circuit, and the output end is a frequency conversion circuit. As a result, the voltages and currents on the input and output sides include abundant ...
|
|
Delta UPS uninterruptible power supply R-2K series
With the increasing demand for system switching power supply by computer technology, Delta UPS uninterruptible power supply R-2K series products have been paid more and more attention, and gradually developed into a kind of electrical engineering with the effects of voltage stabilizer tube, frequency stabilization, filtration, anti-electromagnetic and frequency emission influence, anti-operation voltage swimming, etc.
|
|
Analysis and correction of the cause of Delta servo drive alarm
Analyze and correct the cause of Delta servo drive alarms.
Control current and undervoltage protection.
Alert Number: 11.
Reason: The voltage at the end of the dynamic DC bus is lower than the specified value. Due to the instantaneous shortage of power supply capacity, the control voltage is too low.
Measure: Measure the DC bus ...
|
|
The inverter has a built-in PLC function - Delta
PLC progressive scanning standard work preparation.
Abundant programming language: instruction statements; ladder diagram; SFC。
Abundant instruction statements: 45 instruction varieties, including 28 root instructions and 17 usage instructions.
350 step law capacity.
uS-level root directives ...
|
|
Delta's servo motor maintenance and safety measures
Delta's servo motor system is planned for industrial use, and it is necessary to have a sufficient understanding of the motor standards and operation manuals before operating the motor. For the safety of the operator and equipment, and to ensure that the motor can be used correctly, please read this safety precaution carefully before installing the machine.
...
|
|
Inverter Fault Repair Test Method - Delta
Static quizzes
1. Test the rectifier circuit
Find the P and N ends of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, connect the red watch rod to P, and separate the black watch rod to R, S, T. Instead, connect the black watch rod to the P...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Requires an inverter speed control application – Delta
Inverter is a kind of speed regulation equipment, where is there a place to use motor speed regulation, especially asynchronous motor speed regulation, will use inverter, now it is mainly used in industrial equipment on a large scale, because the motor is the heart of industry, and three-phase asynchronous motor occupies the vast majority of the share, ...
|
|
Precautions for storage of Delta inverter VFD-VE
It must be placed in a ventilated, dust-free, dry place.
The ambient temperature of the storage location must be in the range of -10°C to +40°C
The relative humidity of the storage location must be in the range of 0% to 90% and be free of dew.
...
|
|
Delta's inverter product recommendation
Delta was established in 1971 to provide power supply and heat dissipation treatment programs for the world. Over the past 20 years, Delta's development in Chinese mainland has become increasingly deep-rooted, and its business operations cover development, production, sales and service. With innovative skills, we will continue to strengthen engineering research and development equipment and sophisticated testing ...
|
|
Delta's inverter power-on debugging method
After the inverter is installed, disconnect the output of the inverter, use the diode file of the digital meter to measure the input and output of the inverter before the power is not turned on, ensure that there is no short circuit, and then turn on the working power supply of the inverter.
|
|
Description of Delta inverter problems and solutions
Problem Description:
What is stall avoidance?
Solution(s):
If the given acceleration and deceleration time is too short, the output frequency of the inverter changes faster than the motor speed, and the inverter will stop working due to overcurrent, which is called stalling. In order to make the motor ...
|
|
Precautions for Delta's DPA pressure sensor
1. When the device is installed, leave the place with high voltage and strong high-frequency noise to prevent disturbance. Prevent use in places where the following conditions occur:
(a) Excessive dust and corrosive gases; (b) high humidity and very high radiation; (c) ...
|
|
The principle, composition and function of Delta's inverter
1. What is a Delta inverter?
Delta inverter is a device that converts the power supply (50Hz or 60Hz) into a communication power supply of various frequencies to realize the variable speed operation of the motor.
|
|
Introduction to Delta's RH series switching power supply
Delta's RH series switching power supply, RH series switching power supply is a high-quality power supply product series planned by Delta Power for industrial applications, with the characteristics of high rate, high reliability and high function. This series of products has a wide range of input voltages and can be applied to a variety of power input ...
|
|
Precautions for inverter selection - Delta
The selection of the inverter is mainly determined by the load characteristics of the drive and the actual working current of the motor, in addition to the following precautions:
1. The environment is suitable for some high temperature (higher than 50 degrees) and high altitude (higher than 1000 meters).
|
|
What are the series of Delta inverters?
1:VFD-EL,VFD-S,VFD-L,VFD-C200
Voltage 220V, 380V, power scale 100W-7.5kw
The above series are Delta's simple inverters, commonly known as economical inverters, which are used for small fans and pumps, conveyor belts on food and pharmaceutical machinery, etc., and are used for abbreviated ...
|
|