Delta inverter repair steps

Create Date: 2024-8-30 12:03:23|Source: Delta/Delta

Delta inverters still have a certain influence in the industry, but even if the reputation is good, it will inevitably show some failures. Let's take a look.

                               Delta inverter repair steps

First, the inverter repair must first check whether the sound in the operation of the motor is abnormal, including, whether the motor operation is causing a sensation.

2. Check whether the natural environment of the inverter installation has changed. For example, whether the operating temperature is normal. Anyone who understands the maintenance of Delta's inverter should know that the operating temperature of the inverter is generally specified in the range of -10°C to +40°C, and it is advisable to go up and down 25°C.

3. Check whether the inverter heat exhaust fan is in normal operation, for example, whether the inverter heat exhaust safety channel is unobstructed, and whether the main parameters of the inverter on the indicated control panel are normal.

Fourth, the inverter repair also has to check whether the inverter is high temperature. You can use an infrared thermometer to check whether the radiator of the inverter is high temperature or whether it has a strong odor. It is also necessary to check whether there are common fault alarms in the operation of the inverter.

5. The protection and maintenance of Delta's inverter should also ensure that the filter screen of the air inlet pipe inside the low-voltage complete set of equipment is lifted on time on a daily basis. Long-term maintenance of the control box and inverter in excellent finishing condition. Because that can reasonably remove the area dust on the inverter, but also prevent the dust from entering the inverter, reasonably remove the oil stains of the inverter fan, and reduce the generation of heat exhaust problems.

Delta's DVP-1 22KW inverter has no reflection when powered on, no display on the actual operation control panel, and the 24V operating voltage of the control terminal is 0. Identify the common faults of the power supply system circuit of the switching power supply circuit or the switching power supply circuit. There is no 530V communication voltage at both ends of the energy storage capacitor of the direct current circuit.

Further check that the circuit breaker FU of the pre-charging circuit has already melted, resulting in the switching power supply circuit unable to get the input power supply, and the whole machine strikes. The reason for the full consideration of melting is that the thyristor in the three-phase rectifier circuit is not triggered to open and off, and the pre-charged power supply circuit is subjected to current impact, so the FU is melted.

After replacing the FU with a new one, the power is turned on, and the communication voltage cannot be checked at the trigger terminals of the three thyristors. When the short contact is with VT3 in the power generation circuit, the trigger terminals of the three thyristors are all triggered by the operation voltage, and the three thyristors are turned on. Check that the collector junction of VT3 has long been destroyed by open circuit, and after replacing VT3 with power transistor BU406, the common fault is resolved.

More on that
The inverter needs to prepare the braking resistance condition - Delta The inverter needs to prepare the braking resistance condition - Delta

The preparation of the braking resistor of the inverter is mainly to consume part of the energy on the DC bus capacitor through the braking resistor to prevent the capacitor voltage from being too high. Theoretically, if the capacitor stores a large amount of energy, it can be used to release it to drive the motor and prevent energy waste. However, the capacitance of the capacitor is ...

Several veins of the inverter circuit - Delta inverter Several veins of the inverter circuit - Delta inverter

1. Vibration circuit: the leakage-source and R4 of the main winding N1 and Q1 of the switching transformer are the channels of the power supply operation current; R1 provides the starting current; The self-powered windings N2, D1, and C1 constitute the power supply voltage of the vibrating chip. The normal operation of these three links is the prerequisite for the power supply to vibrate.

When the Delta inverter is powered on, the uptube drive voltage is established When the Delta inverter is powered on, the uptube drive voltage is established

One is hardware, similar to the CPU reset circuit, which gives the downtube a short high-level drive pulse during the initial power-up, and then the voltage drops to 0 to cut off the downtube. The second is the software, when the CPU is operating normally, it outputs a square wave pulse that only needs to be turned on by the lower three tubes, so that the upper tube ...

Wind turbine inverter speed regulation effect - Delta Wind turbine inverter speed regulation effect - Delta

What is the effect of speed regulation of fan inverter? According to the query materials, in industrial production, the throttling loss of the damper, baffle and other related equipment of the fan, as well as the protection and maintenance costs account for 7%-25% of the production cost.

The reason why the circuit breakers of multiple stages trip together is Delta The reason why the circuit breakers of multiple stages trip together is Delta

Short-circuit maintenance (overload maintenance) is an important function of circuit breakers, and the reason why this function is achieved is that the circuit breaker senses the temperature in the circuit through a thermal iron plate. Once the temperature in the circuit is too high, it is transmitted to the mechanical mechanism in the circuit breaker for trip maintenance. ...

Analysis of abnormal operation of Delta inverter Analysis of abnormal operation of Delta inverter

There are many setting parameters of the inverter, each parameter has a certain selection range, and the phenomenon that the inverter can not operate normally is often encountered in the application due to the improper setting of a single parameter, so the relevant parameters must be set correctly. ...

DC motor speed regulation method - Delta DC motor speed regulation method - Delta

There are three speed regulation methods for DC motors: armature loop string resistance, armature voltage regulation and speed regulation, and weak magnetic field speed regulation. The three speed regulation methods can achieve stepless speed regulation. 1. Armature loop string resistance The applied resistor is connected to the armature circuit.

Delta's PLC-Based motion controller AX3 series Delta's PLC-Based motion controller AX3 series

With the development of electronic semiconductor information technology, technologies such as the Internet of Things, big data, and cloud channels are showing a trend of a hundred flowers blooming, which also drives the rapid development of intelligent production. Intelligent production also puts forward new requirements for controllers: high speed, large capacity, miniaturization, networking...... In order to ...

In 2020, Delta once again won the Outstanding Human Resource Optimization Award In 2020, Delta once again won the Outstanding Human Resource Optimization Award

Not long ago, Delta was awarded the "2020 Excellence Award for Optimal Allocation of Human Resources Resources" by the Human Resource Management Service Project Organization "Future", which stood out from more than 5,000 companies. This is also the second time since 2018 that Delta has won this honor. Delta ...

The reason for the slow response after the frequency converter potentiometer adjusts the frequency - Delta The reason for the slow response after the frequency converter potentiometer adjusts the frequency - Delta

The external use resistor is an external operation form of the inverter, which controls the inverter through the external operation signal generated by the external starting switch and frequency setting potentiometer. The regular external voltage signal of different inverters is different. ...

The robot reducer accessories are faulty The robot reducer accessories are faulty

Robot harmonic reducer is a kind of power transmission organization, which uses the speed converter of the gear to reduce the number of revolutions of the motor (motor) to the required number of revolutions, and obtains a larger torque organization. The scale of use of the reducer is quite extensive, if the noise of the reducer is too loud, it will hinder people ...

The impact of grid quality on the life of the inverter – Delta The impact of grid quality on the life of the inverter – Delta

Inverter is a high-tech product, mainly composed of power electronic equipment and microelectronic equipment. The three-phase communication grid is connected to the input of the frequency converter. The input end of the inverter is a rectifier circuit, and the output end is a frequency conversion circuit. As a result, the voltages and currents on the input and output sides include abundant ...

Set the parameters when reading and uploading the Delta PLC program Set the parameters when reading and uploading the Delta PLC program

Open Delta's programming software, and use WPLSOFT to do the demo here; First, click on the settings and then click on the communication settings in the settings, select the communication mode, communication port, communication baud rate, communication station number, etc. After the setting is finished, click OK to automatically close the pop-up window. In the dish ...

Delta launched an integrated control solution for layer winding Delta launched an integrated control solution for layer winding

As factories move from automation to intelligence, the requirements for equipment performance and scalability are progressing day by day. In response to the rapid development of electronic engineering, transportation and mechanical engineering and other occupations, in order to quickly manufacture related product parts and components, metal coil winding technology is also being carried out at a high speed.

Do Delta thermostats have a "slope control" function? Do Delta thermostats have a "slope control" function?

Delta's thermostats are only available in the DTE series (variety 1.5 and above) with the "slope control" function. Illustrate the following examples: For example: PV=20°C, SV=100°C, slope 10.0°C/min Then (100 – 20)/10.0 ...

Advantages of Delta inverters Advantages of Delta inverters

1. Control the starting current of the motor: when the motor is directly started through the I frequency, it will generate 7 to 8 times the rated current of the motor, and this current value will greatly increase the electrical stress of the motor winding and generate heat, thereby reducing the life of the motor. The acid frequency speed regulation can be started at zero speed and zero voltage (can also be ...

A number of Delta's new high-end power supply products were unveiled at CMEF A number of Delta's new high-end power supply products were unveiled at CMEF

Delixi Electric's newly launched CDQ1F series PC-level excitation active transfer switch, with more complete specifications and stronger functions, the power-off time can be shortened to less than 0.1s, escorting the continuous use of electricity in important places! CDQ1F Active ...

How to use a PC to control Delta's inverter How to use a PC to control Delta's inverter

Problem Description: How does Delta inverter use a PC to control it? Solution(s): The communication interface of Delta's inverter is based on RS485 and the ModBus communication pattern commonly used in the general industry for material handing.

Delta inverter failure and maintenance Delta inverter failure and maintenance

Delta's inverter problem 1: Communicate with the motor driver to explore the formation of overvoltage conditions on the internal DC high-voltage power supply side Check whether the keyed operating voltage is in the field of the additional value of the communication motor driver keying operating voltage, and detect whether there is a surge operating voltage formation If it is due to ...

Delta's touch screen controls the inverter method Delta's touch screen controls the inverter method

1. The touch screen is controlled by PLC inverter 1. Now the general control of the inverter needs to use PLC to communicate with the inverter, read the information of the inverter, and then the touch screen communicates with the PLC in order to complete the control of the inverter to start, stop, and monitor the operation of the inverter.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top