[1] Yaskawa 5 series 1KW drive on telegram 030 what is the reason?

When you power on, it will display 030, check the manual to explain: the main circuit is abnormal in various detection data, and there is no problem with the main circuit module after checking.

Is there a motherboard can be swapped to try,If not, you can change the 7860 optocoupler,I met one before is occasionally reported 030,But after a power failure and restart a few times, it will not be reported,Later, the overload warning is packed,Detection 7860 is also good,But if you change 7860, you won't call the police。

【2】Yaskawa drive maintenance order?

1. The fault of the servo drive first looks at the reported fault code and the fault record, so as to roughly judge the fault range of the servo drive.

2. Measure the voltage signal and on-off signal according to the fault phenomenon.

3. Common encoder faults, overcurrent faults, overvoltage faults, transistor dynamic faults, communication faults, etc.

4. Measure the quality of IGBT and brake resistance, whether the control line is loose, ignition marks, whether the encoder line is loose and whether it can be counted normally.

[3] Yaskawa servo alarm code A810?

A: A.810 A.81 Encoder Backup Encoder's power supply is completely depleted and the location data is cleared.

[4] The customer reacted that the Yaskawa server was powered on and reported C90, what is the reason?

Answer: C90 is the encoder communication failure, detect the connecting line. Swap the driver under the test and make sure it is not a problem with the line, then it must be the driver who asked.

[5] How to solve the alarm of Yaskawa servo drive 840?

Answer:

1. First of all, when the oscilloscope checks the current monitoring output of the driver, it is found that it is all noise and cannot be read, and it can be detected and observed with a DC voltmeter.

2. Then the motor runs faster in one direction than the other because the phase of the brushless motor is wrong. To detect or isolate the correct phase. When not used for testing, the test/deviation switch hits the test position.

[6] What does Yaskawa servo drive report 910 mean?

A: 910 alarm.

1. The encoder is disconnected or the contact is not enough.

2. The servo drive itself is faulty.

3. Caused by interference.

4. Servo motor encoder feedback unit failure.

[7] What does Yaskawa servo drive alarm code A91 mean?

A: A.910: Overload. (This is the warning display before the overload (A.710 or A.720) alarm is about to be reached.) If it continues to run, there is a chance that an alarm will occur. ); A.710 Overload (Instantaneous Maximum Load) and A.720 Overload (Continuous Maximum Load) were operated continuously at torques exceeding the rated value.

[8] Yaskawa SGDB power on A30 alarm?

Q: I use servo drive SGDB-30ADG servo motor SGMG-30AABB drive nominal 3 phase 200V ...

Answer: Don't connect it like that, the general detection circuit is on the 1 and 3 items, that is, the R and T items, you will connect L, N, and only connect these two items to see the S end empty to try.

[9] What does Yaskawa servo alarm AF5 mean?

A: Yaskawa servo alarm AF5 refers to check the motor power line, short circuit or broken wire. There are two possibilities for the AF5 alarm fault in the Yaskawa servo: it occurs when the control power supply is put in, then it is caused by the fault of the servo unit circuit board, and the servo unit needs to be replaced.
Yaskawa Servo Drive FAQ (1-9)


More on that
Yaskawa servo alarm C90 (AC9) troubleshooting method Yaskawa servo alarm C90 (AC9) troubleshooting method

1. Analysis of the causes of Yaskawa servo alarm C90 (AC9): 1. The encoder cable is broken or the encoder plug is made in poor process (there are also wiring errors in the alarm of the new machine); 2. The servo drive itself is faulty; 3. Environmental interference, caused by poor connection: ...

Yaskawa inverter maintenance method Yaskawa inverter maintenance method

Yaskawa inverter failure and maintenance method.   The switching power supply is damaged. Switching power supply damage is the most common fault in many frequency converters, usually caused by a short circuit in the switching power supply load. The 616G3 uses two switching power supplies, which is somewhat similar to the Fujifilm G5. First of all, the DC bus side 530 volts ...

Yaskawa servo drive alarm 810 reset method Yaskawa servo drive alarm 810 reset method

1. Check the reason for alarm 810: Alarm 810 is caused by the temperature inside the controller is too high, which may be caused by the heat inside the controller is too high or the power supply voltage is unstable. 2. Check the heat dissipation of the controller: check whether the radiator of the controller is blocked, ...

Part of the configuration process for Yaskawa drives Part of the configuration process for Yaskawa drives

1. "Restore factory settings": Perform a factory reset after power-on to avoid some previously set parameters in the inverter (of course, if it is a new inverter, this problem does not exist). 2. "Set the motor type": whether the motor is an asynchronous motor or the same ...

What are the reasons for Yaskawa servo A71 alarm in addition to overload? What are the reasons for Yaskawa servo A71 alarm in addition to overload?

1. It occurs when the power is turned on It's a servo unit fault 2. On servo on is happening It is an abnormal wiring of the motor (there is a connection problem or there may be a wrong wire, I encountered a wrong phase) 3. The encoder wiring is abnormal Servo unit failure 4. Re-enter the finger ...

Yaskawa Robotics - Introduction to the six subsystems of industrial robots Yaskawa Robotics - Introduction to the six subsystems of industrial robots

Industrial robot is a multi-degree of freedom machine device, can automatically perform work, according to its own power and control ability to achieve various functions, by the mechanical part, sensing part, control part and other three parts, these three parts are divided into six subsystems, namely: 1. Drive...

Wiring method of Yaskawa A1000 inverter Wiring method of Yaskawa A1000 inverter

First, the wiring of the main circuit 1. The power supply should be connected to the R, S, and T terminals at the input end of the inverter, and must not be connected to the output terminal (U, V, W) of the inverter, otherwise the inverter will be damaged. After wiring, the fragmented wires must be cleaned, and the fragmented wires may cause abnormalities. ...

Yaskawa robot spraying process application virtual simulation operation method Yaskawa robot spraying process application virtual simulation operation method

Spraying is another common process application of industrial robots, second only to welding process applications, and they all belong to high-intensity, high-precision, and high-sensitivity work tasks in harsh environments. The spraying process has extremely high requirements for the performance of the robot, of course, for the formulation of the process, ...

Yaskawa servo motor MP2300/MP2310/MP2300S function introduction Yaskawa servo motor MP2300/MP2310/MP2300S function introduction

It is an all-in-one controller with built-in power supply, CPU, communication and servo control. From simple positioning and interpolation to advanced multi-axis control, we are looking for cost-effective devices. Compatible with open networks Just install the optional module in the slot, which not only corresponds to the open network, but also ...

Yaskawa Robotics - What is the processing structure of the robot controller? Yaskawa Robotics - What is the processing structure of the robot controller?

1. Serial processing structure The so-called serial processing structure means that the control algorithm of the robot is processed by the serial machine, for this type of controller, from the computer structure, control mode to divide, and can be divided into the following: 1. Single CPU structure, centralized control mode ...

Yaskawa servo motor - ten common faults and troubleshooting methods of servo motors Yaskawa servo motor - ten common faults and troubleshooting methods of servo motors

1. Motor encoder alarm 1. The cause of the failure (1) Wrong wiring; (2) electromagnetic interference; (3) Encoder hardware damage caused by mechanical vibration; (4) Pollution caused by the on-site environment; 2. Troubleshooting (1) Check the wiring and eliminate the error ...

How to use the inverter and adjust the parameters How to use the inverter and adjust the parameters

First, the use of the inverter: (1) First connect the power supply, link the inverter with the motor, and ensure that the working voltage of the inverter and the power of the motor meet the requirements. (2) Set the parameters of the inverter, adjust the speed and load of the motor to ensure the normal operation of the motor.

What could be the cause of the CF failure of Yaskawa inverter? What could be the cause of the CF failure of Yaskawa inverter?

The fault code is CF refers to Control Failure, which reaches the torque limit for more than 3 seconds in the deceleration stop (no PG vector control mode) Possible reasons are: The motor parameters are not set correctly The set value of the torque limit is too small The load inertia is relatively ...

Yaskawa Electric - Introduction to the starting method of three-phase asynchronous motor Yaskawa Electric - Introduction to the starting method of three-phase asynchronous motor

There are three main starting methods of three-phase asynchronous: direct start, traditional decompression start and soft start. Direct start, also called full pressure start. Decompression starting is to reduce the voltage on the stator winding during starting, and then restore the voltage to the rated after starting. Include...

Yaskawa MOTOMAN servo drive fault repair case summary (1-2) Yaskawa MOTOMAN servo drive fault repair case summary (1-2)

1. The motor runs faster in one direction than in the other; (1) Cause of failure: The phase of the brushless motor is wrong. Solution: Detect or detect the correct phase. (2) Cause of failure: When not used for testing, the test/deviation switch hits the test position ...

The main recommended models for Yaskawa inverters The main recommended models for Yaskawa inverters

Yaskawa inverter is mainly used in the following series: Low-pressure type V1000: Amazing! A small inverter is controlled using a simple real current vector J1000: High reliability from a compact inverter! Simple operation, simple setting Varispeed ...

Yaskawa CH700 inverter innovatively integrates anti-sway control technology Yaskawa CH700 inverter innovatively integrates anti-sway control technology

When the crane is working, the start and stop of the cart and trolley mechanism, as well as the acceleration and deceleration process, will cause the suspended load to swing, which not only reduces the production efficiency but also brings great safety hazards to the staff and related equipment. And Yaskawa Electric has been deeply involved in ...

A detailed introduction to the important accessories of Yaskawa robots A detailed introduction to the important accessories of Yaskawa robots

1. Controller The controller is mainly responsible for issuing and transmitting action instructions, controlling the movement position, posture and trajectory of industrial robots in the workspace, operation sequence and action time. The controller is divided into hardware structure and software structure. In terms of hardware, the current market has ...

Yaskawa inverter – how to check for inverter failure Yaskawa inverter – how to check for inverter failure

1. Static test 1. Test the rectifier circuit Find the P and N ends of the DC power supply inside the inverter, adjust the multimeter to the resistance X10 gear, connect the red watch rod to P, and separate the black watch rod to R, S, T. Instead, take the black watch rod ...

Two cases in which the origin of the Yaskawa robot is lost Two cases in which the origin of the Yaskawa robot is lost

There are two scenarios in which the origin of the Yaskawa robot is lost: A. Loss of the origin of individual shafts; B. Lose all axis origins. ● All axes are created at the same time: When the combination of the robot and the control cabinet is changed, all axes are registered at the origin position at the same time. ● Each axis is created separately: replace ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top