Calibration process of a tension transducer – Autotonics

Create Date: 2024-8-30 12:03:23|Source: Autonics/Autonics

1. Plug in the force sensor you want to calibrate, such as a force sensor with a range of 50kg, and select a force sensor channel on the left;

2. Enter the range of the sensor in the "range" input box, such as "50" kg;

3. Enter the zero value force of the sensor in the "zero value" input box, generally enter "0";

                               Calibration process of a tension transducer – Autotonics

4. Click the "Empty" button to empty the calibration table;

5. Calibrate the di1 point: the sensor is unloaded, press the force to zero, and enter "0" kg in the input box on the right side of the "standard weight value", and then click the "take point" button, then the AD value and standard weight value of the di1 point are taken into the calibration table;

6. Calibration point 2: load the sensor with a certain value of load, such as hanging a 5kg weight, and enter the load value "5" kg in the input box on the right side of the "standard weight value", and then click the "take point" button, then the AD value and standard weight value of the second point are taken into the calibration table;

7. Calibration point 3: The method is the same as point 2, assuming that the calibration point 3 continues, the "AD value" and "standard weight value" can only be larger than the second point, otherwise the calibration will be inaccurate;

8. Calibration point 4: The method is the same as point 2, assuming that the calibration point 4 continues, the "AD value" and "standard weight value" can only be larger than the 3rd point, otherwise the calibration will be inaccurate;

9. Calibration point 5: The method is the same as point 2, assuming that the calibration point 5 continues, the "AD value" and "standard weight value" can only be larger than the 4th point, otherwise the calibration will be inaccurate;

10. Calibration point 6: The method is the same as point 2, assuming that the 6th point is continued to be calibrated, the "AD value" and "standard weight value" can only be larger than the 5th point, otherwise the calibration will be inaccurate;

11. Click the "Write calibration data to the acquisition card" button, assuming that it prompts "Write successfully", then the calibration of a force transducer will be completed, and if it says "Write failed", please try again a few times.

12. Assuming that the second force transducer is required, repeat the above steps 1-11, otherwise please set the range of other sensors to 0, and then click the "Write calibration data to the acquisition card" button

More on that
Wiring of the load cell – Autonex Wiring of the load cell – Autonex

The load cell can be wired in two different ways with input and output: One is the four-wire connection method The load cell of the four-wire connection method has no special requirements for the secondary instrument panel, and it is very fast to use, but when the cable is long, it is very easy to be affected by the working temperature.

Instrumentation Fault Diagnosis Method - Ottonix Instrumentation Fault Diagnosis Method - Ottonix

1. Percussion hand pressure method It is common to encounter the phenomenon of good and bad operation of the instrument, and most of this phenomenon is due to poor contact or virtual welding. In this case, percussion and hand pressure can be used. The so-called "percussion" is to ...

Introduction to the principle of temperature controller - Autonix Introduction to the principle of temperature controller - Autonix

The temperature controller is an electrical switchgear that controls the temperature of an air-conditioned room. The temperature scale in the air-conditioned room controlled by the temperature controller is generally 18°C--28°C. The temperature controller commonly used in window air conditioners uses the principle of pressure effect to promote the opening and closing of contacts. Its structure consists of bellows ...

Introduction to the Autonex differential pressure flow meter Introduction to the Autonex differential pressure flow meter

The differential pressure flowmeter calculates the flow rate according to the differential pressure generated by the flow test piece installed in the pipeline, the known fluid conditions, and the size of the test piece and the pipeline. The differential pressure flowmeter consists of a primary device (test piece) and a secondary device (differential pressure conversion and flow display) ...

Autonix thermostat TZ4ST-24R features: Autonix thermostat TZ4ST-24R features:

Dual PID auto-adjustment function There are high-speed response modes and slow reaction modes in the PID function. When you want to reach the desired value quickly, use the high-speed mode (PIDF mode) When you want to minimize overshoot, use slow mode (PIDS mode) ...

Introduction to Torque Transducers – Autotonics Introduction to Torque Transducers – Autotonics

1. Characteristics 1. It can not only measure the constant motion torque, but also measure the rotational rotational distance; 2. It can measure both non-static torque and static torque; 3. High precision and good reliability; Strong anti-interference ability; 4. Light weight, very light, all kinds of ...

Pressure sensors can't avoid errors – Ottonix Pressure sensors can't avoid errors – Ottonix

When choosing a pressure sensor, we should consider his inductive accuracy, and what are the aspects that affect the accuracy of the pressure sensor? In fact, there are many factors that form sensor errors, and let's pay attention to four unavoidable errors, which are the initial errors of the sensor. ...

Introduction to the resolution of the Autonoix encoder Introduction to the resolution of the Autonoix encoder

Depending on the resolution supported by the encoder, encoders can be divided into marker encoders, HD encoders, and Full HD encoders. The higher the frame rate, the clearer the video. 1. What does the resolution of the encoder mean? The resolution of the encoder refers to the encoder passing through a line or a dark line (also ...

Key points of visual inspection of electric motors - Ottonix Key points of visual inspection of electric motors - Ottonix

Key 1: Whether the speed of the motor is normal, whether there is speed jitter and stalled rotation (you can check it with a tachometer). The key is whether the anchor bolts of the motor are loose, whether the root is defective, and whether there are debris around. The key is three, whether the housing and coupling of the motor are defective, ...

Autonex SFC series safety controllers Autonex SFC series safety controllers

The SFC series of safety controllers can be used with safety input products (switches, sensors, etc.) and satisfies the self-diagnosis function and safety integrity required by safety standards. In addition, the slim design saves space in the installation and allows for the use of screwed/screwless pushes for wiring connections.

Autonex TR1D series temperature controller features Autonex TR1D series temperature controller features

The TR1D series has a high-speed sampling period of 50ms and a display accuracy of ±0.3%, which can complete more accurate temperature control. Heating/cooling can be operated together to provide useful temperature control. With a width of only 22.5mm, the product minimizes the limitation of installation space and can be passed through ...

How to choose a pressure sensor fitting – Ottonix How to choose a pressure sensor fitting – Ottonix

At present, there are not many single ferrule terminal joints on the market, and most manufacturers are using double ferrule terminal joints, and the market price is about 9-18 yuan, and the price is different according to different types. Fittings, whether they are double ferrule end fittings or single ferrule end fittings, are all ...

Introduction to Digital Fiber Optic Sensors Introduction to Digital Fiber Optic Sensors

Digital fiber optic sensors convert measured objects into measurable optical signal sensors. Its working principle is to send the incident beam of the light source to the modulator through the optical fiber, and interact with the internal and external measurement parameters of the modulator to form a dimmable signal. Digital Fiber Optic Sensors ...

Sensor fault judgment and solution - Autonics Sensor fault judgment and solution - Autonics

1. Air flow meter problem Problem characteristics: The vehicle is shaking at idle, high fuel consumption, weak at high speed, and black smoke from the exhaust pipe. View and dissect: through the fault diagnostic instrument detection, the engine air flow meter data block is seriously exceeded, the cause of the air flow meter damage, ...

Advantages of digital torque sensors – Autotonics Advantages of digital torque sensors – Autotonics

In the rotary power system, the most frequently involved parameter: rotational torque, in order to detect the rotational torque, the traditional use of torsion angle phase difference sensors. The more mature detection method of torque testing is strain electrical testing skills. It has high precision, fast frequency response, good reliability, long life, etc.

Strengths of Autonex photoelectric sensors Strengths of Autonex photoelectric sensors

1. Long detection interval. By retaining an inspection interval of more than 10 m in the through-beam model, other inspection methods can be accomplished. 2. Less detection of objects. Because the detection of shading and reflection caused by the object is the detection principle, it is not like the proximity sensor to limit the detection of the object to the metal ...

Autonex PSK series 2-segment display pressure sensor Autonex PSK series 2-segment display pressure sensor

The PSK1 series is a two-stage display pressure sensor that displays the current value (PV) and the set value (SV) together. It not only shows the setting status, but also provides a power-saving form and a fine-tuning function to improve the user's convenience. PSK1 Key Features: Additional pressure scale (composite pressure ...

Principle and application field of Ottonix panel table Principle and application field of Ottonix panel table

Panel meter, also known as the dial table or meter head, the full name is the panel device instrument (panel device instrument), English Panel Meter. Because this kind of instrument device is fixed on the surface of the equipment for viewing and operation, it is called a panel table, which is a functional part of the screen equipment. ...

Precautions for the use of fiber optic sensors Precautions for the use of fiber optic sensors

SET button, which can be used to set the sensitivity. The basic principle of the sensor is to sense the refractive index of different media through a fiber optic probe, so as to obtain a digital signal, display it on the screen, and send the switching value by comparing the magnitude of the displayed value and the set sensitivity value. Indicator light when the sensor ...

High Temperature Pressure Sensor Accuracy Affects - Autonex High Temperature Pressure Sensor Accuracy Affects - Autonex

A high-temperature pressure sensor is a sensor that converts pressure into an electrical signal output, which usually consists of two parts, namely a sensitive element and a conversion element. The sensitive element refers to the part of the sensor that can directly feel or respond to the measurement; The conversion element refers to the sensitive element in the sensor ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top