SET button, which can be used to set the sensitivity. The basic principle of the sensor is to sense the refractive index of different media through a fiber optic probe, so as to obtain a digital signal, display it on the screen, and send the switching value by comparing the magnitude of the displayed value and the set sensitivity value. Indicator, when the sensor has a signal output, the indicator light is on. "Set Sensitive Value" appears in green on the screen to show the sensitive value set at that time. When the value collected by the probe becomes that value, the sensor generates a signal. The Current Sensitivity Value appears red on the screen to show the value collected by the sensor at that time. The "Pick Button" and the left and right arrows can complete the selection of various functions, which is equivalent to the page turning button. Form Selection Button: This button can be used to set up different work forms.
It must not be installed in the following places: direct sunlight, high humidity, frost, corrosive gases, direct oscillation or impact; When the power cord, power cord and photoelectric switch use the same wiring pipe or wiring duct, in principle, due to induction or product damage, separate wiring or shielded wires should be used. Use a 0.3 mm line to control the temperature above 1000 mm and below m, and when the power is turned on, it can be detected at least 200 ms. When the load is separated from the fiber sensor power supply, be sure to connect the fiber sensor power supply first; When the power supply is blocked, the output pulse will be presented, so the power supply of the load or load line is first blocked; When using the plug-in, in order to avoid electric shock or short circuit, please attach a maintenance patch to the unused power supply terminal; When removing and installing the expander, be sure to block the power supply; When the fiber optic unit is fixed in the expander unit, do not stretch or contract; Ensure that the protective cover is covered during use; Do not wash with banana water, gasoline, acetone, or lamp oil.
Instructions for the use of fiber optic sensors and precautions for use? Fiber optic sensors can also be divided into types such as retroreflective and diffuse reflection. Fiber optic sensors are able to detect objects from a distance. Because of fiber loss and dispersion, long-distance fiber transmission systems must be equipped with a center amplifier at the appropriate location on the line to process and amplify attenuated and distorted optical pulse signals.
|
More on that
|
Pressure Sensor Fault Detection – Ottonix
First, the first component is blocked or the form of the device is wrong, and the pressure point is unreasonable, so we often emphasize that the device must be the correct device, once it is installed wrongly, or it is not well installed, it will bury endless hidden dangers for the back. What are the primary components? Orifice plates, remote transmission measuring joints, etc.
|
|
Autonex BD series laser displacement sensors
BD series laser displacement sensor can measure the thickness, width, horizontal difference, parallax, twist and flatness of the target object by detecting the displacement.
Regardless of the color or data of the policy, the sensor can provide accurate and stable measurement results. Sensor head and amplifier unit ...
|
|
Autonics Single Display PID Temperature Controller TR1D Series New Product Released
The TR1D series has a high-speed sampling period of 50ms and a display accuracy of ±0.3% for more accurate temperature control. Simultaneous heating/cooling control is available to provide effective temperature control. With a width of only 22.5mm, the product minimizes the limitation of installation space and can be accessed with ...
|
|
Precautions for the use of gas flow meters - Autonex
1. When the working conditions of the exterior are changed (such as changing the medium, changing the ambient temperature, etc.), the zero position of the exterior should be adjusted from the beginning. At the same time, the outer surface of the catheter must be leveled and calibrated with a spirit level. Failure to do so will increase the effect of the change in operating conditions on the zero drift. Rack ...
|
|
How to choose a pressure sensor fitting – Ottonix
At present, there are not many single ferrule terminal joints on the market, and most manufacturers are using double ferrule terminal joints, and the market price is about 9-18 yuan, and the price is different according to different types. Fittings, whether they are double ferrule end fittings or single ferrule end fittings, are all ...
|
|
Load cell structure and function – Ottonix
Load cells are used to measure weight and can be found everywhere in our daily lives, such as at supermarket counters or on highways.
Load cells generally consist of elastomers with strain gauges. Elastomers are generally made of steel or aluminum. It is very robust and has very little elasticity. ...
|
|
The principle, function and application field of Autonex's products
Panel meter, also known as panel table or meter header, the full name is panel mounted instrument (panel mounted instrument), English Panel Meter. Because this kind of instrument is installed and fixed on the surface of the equipment for viewing and operation, it is called a panel table and is a functional part of the screen equipment.
...
|
|
Rapid detection method for air conditioner thermostat – Ottonix
When the air conditioner cannot operate normally, in addition to checking the starting relay, overheating, overcurrent protector and capacitor of the compressor, it is also necessary to check the main control selection switch of the air conditioner thermostat, which is a very important control protection and actuator component in the electrical control system. Here are a few common types of air ...
|
|
Calibration process of a tension transducer – Autotonics
1. Plug in the force sensor you want to calibrate, such as a force sensor with a range of 50kg, and select a force sensor channel on the left;
2. Enter the range of the sensor in the "range" input box, such as "50" kg;
3. Enter the zero value force of the sensor in the "zero value" input box, generally enter ...
|
|
The difference between laser sensors and photoelectric sensors – Autonicx
First, the difference in working principle
Photoelectric sensors are controlled by converting changes in light intensity into changes in electrical signals. The laser sensor first emits a laser pulse by aligning it with a laser emitting diode. After being reflected, the laser light is scattered in all directions. Partially scattered light returns to ...
|
|
Otonic photoswitch determination
1. Measurement of action distance; When the action piece is close to the sensing surface close to the switch from the front, the distance close to the switch action is the action distance close to the switch, and the measured data should be within the parameters of the product.
2. Release distance ...
|
|
Autonex launches a new product - multi-channel pressure sensor PSM series
The multi-channel pressure indicators of the PSM series can display the measured values of up to 4 or 8 channels of analogue pressure sensors. When used in conjunction with our PSS series pressure sensors, the sensor type, pressure type and range can be automatically recognized without additional settings. Users can also easily ...
|
|
Precautions for Temperature Sensor Installation and Use – Ottonix
1. Errors in improper introduction of devices
In other words, the thermocouple should not be installed too close to the door and the heating place, and the penetration depth should be at least 8-10 times the diameter of the maintenance tube; Maintenance of thermocouples ...
|
|
Autonex PSK series 2-segment display pressure sensor
The PSK1 series is a two-stage display pressure sensor that displays the current value (PV) and the set value (SV) together. It not only shows the setting status, but also provides a power-saving form and a fine-tuning function to improve the user's convenience.
PSK1 Key Features:
Additional pressure scale (composite pressure ...
|
|
The difference between sensitivity, resolution, and accuracy of a sensor
sensitivity
Concept: It refers to the ratio of the change of output △y to the change of input △x in the case of steady-state operation of the sensor, that is, the ratio of the dimension of output and input.
Sensor sensitivity is the slope of the output-input characteristic curve. If the output and input of the sensor ...
|
|
Installation steps for dynamic torque transducers – Autonex
Dynamic torque transducers can be used in the manufacture of viscometers, electric (pneumatic, hydraulic) torque wrenches, which have the advantages of high precision, fast frequency response, good reliability and long life.
Installation process:
1. According to the connection form of the shaft and the length of the dynamic torque sensor, determine the original ...
|
|
Autonics Solid State Relay SSR adds SR(H)2/3 three-phase
Autonics Solid State Relay SSR adds SR(H)2/3 three-phase solid state relay to its family of relays
Autonex proudly introduces you to the new formation of solid state relays, three-phase solid state relays. Compact design, flexible devices, easy ...
|
|
Anti-jamming measures for Autonix sensors
1. Shielding technology
The use of metal materials to make a container, the circuit that needs to be maintained is wrapped in it, which can effectively avoid the disturbance of electric or magnetic fields, and this method is called shielding. Shielding can be divided into electrostatic shielding, electromagnetic shielding and low-frequency magnetic shielding.
2. Electrostatic shielding
...
|
|
Performance Indicators and Characteristics of Load Cells – Autotonicus
Performance indicators of load cell: 1. Dynamic characteristics, 2. Linearity, 3. Hysteresis characteristicsDynamic characteristics refer to the output characteristics of the sensor when the input changes. In practice, the dynamic characteristics of a sensor are generally used to indicate how well it responds to certain specification input signals. This is because the sensing ...
|
|
Causes and solutions for overheating or burning of AC contactor coils
Reasons: 1. The polar surface of the communication core is uneven or the demagnetization air gap is too large;
2. The double coil of DC operation derived from the communication contactor is overheated due to the fact that the normally closed interlocking contact is not released by welding;
3. The frequency of operation is too high;
4. Poor coil manufacturing or due to mechanical damage, absolute ...
|
|