Schneider Thermal Relay Model Meaning

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

The function of the thermal relay is mainly used to carry out overload maintenance on the asynchronous motor, and his operating principle is that after the overload current passes through the thermal element, the bimetal sheet is heated and twisted to advance the action organization to drive the contact action, so as to disconnect the motor control circuit to realize the motor power-off thermal relay parking, and play the role of overload maintenance. In view of the fact that the heat transfer needs to be a long time during the heating and twisting process of the bimetal sheet, therefore, the thermal relay cannot be used for short-circuit maintenance, but can only be used for overload maintenance, and the symbol of the thermal relay is FR.

                               Schneider Thermal Relay Model Meaning

Because the thermal relay operates when heated, the thermal inertia is large, so even if the current through the heating element exceeds the setting current several times in a short time, the thermal relay will not operate immediately. Only in this way, when the motor starts, the thermal relay will not act due to the large starting current, otherwise the motor will not be able to start. On the other hand, if the current exceeds the setting current by not much, it will operate for a long time. It can be seen that the role of thermal relay and fuse is different, thermal relay can only be used for overload maintenance and can not be used for short-circuit maintenance, while fuse can only be used for short-circuit maintenance and can not be used for overload maintenance. In a well-developed control circuit, especially in a motor with a large capacity, both types of maintenance should be available.
More on that
Analysis of 10 reasons for frequent tripping of Schneider leakage switches Analysis of 10 reasons for frequent tripping of Schneider leakage switches

1. Defective device If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action. 2. Leakage switch with ...

Schneider circuit board maintenance work commonly used instrumentation Schneider circuit board maintenance work commonly used instrumentation

Before preparing to do circuit board repair work, you should prepare some things and appearances to help repairers better carry out circuit board repair operations, according to our circuit board repair training center for many years of experience has shown that prepare some necessary circuit board repair things and appearance, to be able to reach ...

Schneider PLC control cabinet installation wiring method Schneider PLC control cabinet installation wiring method

(1) When placing signal cables with different properties into the same conduit, they must be isolated (2) Try to avoid accommodating multiple power cords in the same conduit. When it is necessary to set up, a partition should be placed inside the conduit and the partition should be grounded. ...

Schneider DC air open up plus or minus? How to connect the incoming and outgoing lines? Schneider DC air open up plus or minus? How to connect the incoming and outgoing lines?

The air switch is divided into the upper inlet line and the lower inlet line of the power supply, 1 is - 3 is + 2 is + 4 is - when the upper line is inlet, 2 is + 4 is - This is related to the internal trip curve. DC circuit breaker is used for DC system operation method conversion or fault removal ...

How can industry be high-quality and sustainable? - Schneider How can industry be high-quality and sustainable? - Schneider

Sanya, China, October 21, 2021 – In the context of the ever-changing global development situation and the increasingly urgent response to carbon neutrality, Ruan is moving towards carbon neutrality together with cost reduction and efficiency increase, which has become the focus of attention of many industrial enterprises. As a global digital transformation specialist in power management and automation...

Schneider instrumentation maintenance precautions Schneider instrumentation maintenance precautions

1. When assembling and adjusting the appearance, the original position should be recorded for rehabilitation. 2. When repairing the appearance of precision instruments, if you accidentally bounce small parts away, you should first determine the position where you can fly down.

Schneider Instrumentation Classification Schneider Instrumentation Classification

1. Industrial automation appearance and control system. This is generally referred to as PA, FA in foreign countries. PA is called process automation, and FA is called factory automation. The appearance and control system used in process automation and factory automation belong to this category, and some parts of the appearance of analytical instruments and electrical instruments also belong to the ...

Precautions for the use and maintenance of instruments and meters - Schneider Precautions for the use and maintenance of instruments and meters - Schneider

Attention should be paid to the following matters during the use and maintenance of the appearance of the instrument: 1. Don't blindly knock and bump when overhauling, so as not to expand the problem, and the more you repair, the worse it will become. ​ 2. Do not plug and unplug various control boards and plugs with electricity. Due to the power-on ...

Introduction to Schneider limit switch series Introduction to Schneider limit switch series

1. XCKN compact limit switch Light and medium load use; Waist-shaped device holes for easy adjustment of mechanical errors; Bipolar isolation definitely disconnects the contacts; External waterproof sealing joint, the protection level is higher than that of rubber sleeve sealing pipe; Engineering plastic body, avoid temperature ...

Frequency converter main circuit fault solution - Schneider Frequency converter main circuit fault solution - Schneider

According to the statistical analysis of the frequency and shutdown time of the specific common problems of the inverter, the repair rate of the main power supply circuit accounts for more than 60%; The main operating parameters are set improperly, resulting in about 20% of common problems; 15% of the common problems of manipulating circuit boards; 5% of common problems are caused by incorrect operation and external anomalies ...

Analysis of common problems of Schneider inverter Analysis of common problems of Schneider inverter

1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA? Because the maximum output frequency parameter of the inverter is "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...

The difference between high voltage and low voltage of Schneider inverter The difference between high voltage and low voltage of Schneider inverter

1. What is the difference between high-voltage inverter and low-voltage inverter? Frequency converters can be broadly divided into two categories: high-voltage frequency converters and low-voltage frequency converters. In terms of use, the applicable objects are different, and the high-voltage motor is the same from the principle of speed regulation. From the topology ...

Schneider diode selection experience and substitution method Schneider diode selection experience and substitution method

1. Selection of detection diode Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...

Schneider instrumentation maintenance precautions Schneider instrumentation maintenance precautions

1. Don't blindly knock and bump when overhauling to avoid expansion failures, and the more you repair, the worse it gets. 2. Do not plug and unplug various control boards and plugs with electricity. Due to the strong induced electromotive force generated by plugging and unplugging the control board under the power-on condition, the instantaneous ...

Design and calculation method of inverter braking resistance - Schneider Design and calculation method of inverter braking resistance - Schneider

1. The number of braking resistor boxes is roughly calculated as: motor power (KW)/11.2 (take the upper limit of the integer). 2. The selection of the power of the braking unit is generally (1-2) times the power of the inverter; 3. The function of braking resistor ...

Schneider inverter ATV310 instruction with given Schneider inverter ATV310 instruction with given

The instructions of the inverter are given with the given conf→400- → 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...

Line leakage detection method - Schneider Line leakage detection method - Schneider

Line leakage detection method, leakage check method summary, if a closing, leakage switch will trip, this kind of front leakage, check the method is as follows: 1. Disconnect all the separation gates, close the main gate, close the separation gates one by one, and close them to ...

Advantages of Schneider molded case circuit breaker Advantages of Schneider molded case circuit breaker

The contact orientation is 100% secure As for the circuit breaker, the indication of the handle can also be said to be the fault indicator of the circuit breaker, if it is "blurred" for a while, it may cause irreparable damage. Therefore, according to the requirements of the national standard, in any case, the hand of the circuit breaker ...

Analysis of the causes of frequent overcurrent alarms of inverters - Schneider Analysis of the causes of frequent overcurrent alarms of inverters - Schneider

(1) Caused by incorrect parameter setting. If the acceleration time of the inverter is set too short, the change of the output frequency of the inverter far exceeds the change of the motor frequency, and when the inverter is started, it will trip due to overcurrent. Adjusting the acceleration time accordingly to different load conditions can eliminate this problem.

Schneider miniature circuit breaker code calling Schneider miniature circuit breaker code calling

Schneider miniature circuit breaker code marking method For example: 1-C65N-C20A/2P+VE+30mA+SD, the meaning of each item is: 1--------- identification number C65 ------ serial code N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top