The difference between circuit breaker and air opening - Schneider

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

An air switch, also known as an air circuit breaker, is a type of circuit breaker. It is a switch that only needs the current in the circuit to exceed the rated current will be actively disconnected, which is generally used to avoid circuit overload and short-circuit maintenance (some also have the maintenance function of low voltage) can not maintain electric shock, to put it bluntly, it plays the role of a fuse.

                                 The difference between circuit breaker and air opening - Schneider

。 Air switch is a very important electrical appliance in low-voltage distribution network and power traction system, which integrates control and a variety of maintenance functions. In addition to completing touch and breaking circuits, it can also be used to maintain short circuits, severe overloads and undervoltages caused by circuits or electrical equipment, and can also be used to start motors infrequently.

It is a switch that controls the electrical circuit, and the switch with air as the arc extinguishing medium, and is generally used as the main switch of the electrical circuit. There are 3P, three fronts, 2P, one zero and one fire, 1P, one front.

Air switch principle: when the line is overloaded, although the overload current can not make the electromagnetic tripper move, it can make the bimetal sheet bend upwards when heated, and push the lever to disconnect the hook and the lock to break the main contact. When the line produces a short circuit or severe overload current, the short-circuit current exceeds the current value of the instantaneous trip, and the electromagnetic tripper generates a large enough suction force to suck the armature and hit the lever, so that the hook rolls up and disengages the lock, and the lock breaks the main contact under the action of the reaction spring. On the contrary, when the voltage is normal, the electromagnet catches the armature, and when the voltage drops or the power is lost, the armature is released and the main contact is disconnected. When the power supply voltage returns to normal, it must be re-closed before operation.

The sockets, lamp heads, kitchens, bathrooms, refrigerators, and air conditioners on each road should be put out independently, and each road should have its own air switch, high-power rooms, such as kitchens and bathrooms, and the lines above 4 square millimeters should reach 20A, and the general lamp head lines only need 16A, and each line has specific specifications. When testing whether the air switch is normal, you should ask a professional to use a leakage phase detector to detect. If the air switch is in normal maintenance, the air switch of each circuit will trip on its own, and the leakage maintainer will also trip with it. If the air switch is in an abnormal state, then only the main switch trips, the air switch alone does not trip, and the leakage maintainer does not trip.
More on that
Schneider servo model introduction Schneider servo model introduction

LXM23DU01M3X servo drive 0.1 kW LXM23DU02M3X servo drive 0.2 kW LXM23DU04M3X Servo drive 0.4 kW LXM23DU07M3X Servo drive 0.75 kW LXM23DU10M3X ...

Deterioration site and the principle of higher harmonic generation - Schneider Deterioration site and the principle of higher harmonic generation - Schneider

1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.

Pressure reducing valves in Schneider instrumentation Pressure reducing valves in Schneider instrumentation

A kind of pressure reducing valve in instrumentation refers to a device used to control the pressure value. Pressure reducing valves are usually used in water-related categories, because from the perspective of the transmission medium, the transmission medium of the equipment is mainly water, but we all know that water is a thing that will ...

Schneider XPS safety control module selection method Schneider XPS safety control module selection method

(1) Evaluate the safety control level that the machinery and equipment need to reach (2) Confirm the type of input signal to be monitored and (3) the number of input signals that need to be monitored (4) The number and type of channels that the module needs to output (5) Whether it is necessary to control the output device (such as ...

Schneider PLC signal light meaning Schneider PLC signal light meaning

Take the Schneider PLC with model number TWDLCAA40DRF as an example: The first PWR: is the meaning of power supply; The second RUN: is the PLC operation indicator; Long dark: The application is not fulfilling; Shine: The controller is in a stay or a mistake in performance; Solid on: The controller is in operation ...

Schneider Instrumentation Classification Schneider Instrumentation Classification

1. Industrial automation appearance and control system. This is generally referred to as PA, FA in foreign countries. PA is called process automation, and FA is called factory automation. The appearance and control system used in process automation and factory automation belong to this category, and some parts of the appearance of analytical instruments and electrical instruments also belong to the ...

Features of Schneider explosion-proof inverter box Features of Schneider explosion-proof inverter box

1. Aluminum alloy shell or steel plate welding, surface spraying; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; 3. It is mainly adjusted by changing its output frequency to adjust the speed of ordinary three-phase asynchronous motor, so as to reach the production process.

Schneider circuit breakers, contactors, thermal relays selection Schneider circuit breakers, contactors, thermal relays selection

In daily work, the combination of circuit breaker, contactor and thermal relay is the most common combination of motor power supply circuit, and the circuit breaker is generally the short-circuit instantaneous action of magnetic maintenance, the contactor realizes relay logic control, and the thermal relay overload maintenance. The parameter selection method of these three kinds of gas parts is as follows: ( ...

Schneider Electric inverter applications Schneider Electric inverter applications

Schneider inverter, the full name of "Schneider communication inverter governor", is a well-known inverter brand developed, manufactured and sold by Schneider Electric Group in France. It is mainly used to control and regulate the speed of three-phase communication asynchronous motor, with its stable performance, rich combination functions, outstanding ...

Steps for configuring braking resistors in VFD – Schneider Steps for configuring braking resistors in VFD – Schneider

In the process of controlling the motor, the motor variable-frequency drive (VFD) may still have a certain kinetic energy when the motor rotates intermittently due to factors such as the moment of inertia of the motor, and the braking resistor is required to interrupt the motor. Here's a ...

The energy-saving effect of using frequency converter for fan and pump loads The energy-saving effect of using frequency converter for fan and pump loads

Why is the use of inverter for fan and pump loads to save energy? According to the basic laws of fluid mechanics, it can be seen that the fan pump load is a typical square rotation load, and its main characteristics are: speed n and torque T and load ...

Precautions for the use of Schneider AC contactors Precautions for the use of Schneider AC contactors

There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A When installing, it should be in accordance with the regulations...

Schneider Compact NSX series molded case circuit breaker selection recommendation Schneider Compact NSX series molded case circuit breaker selection recommendation

The molded case circuit breaker is an important part of the maintenance of the low-voltage distribution system and the motor, and maintains the safety of the distribution system and electrical equipment. As an important application scenario of molded case circuit breakers, these key occupations of new infrastructure such as new energy and telecommunications have extremely important equipment performance, stability and adaptability.

Schneider ATV series inverter used as inverter power supply? Schneider ATV series inverter used as inverter power supply?

Can Schneider ATV series inverter be used as a variable frequency power supply? No, you can't. The inverter is a control device designed according to the characteristics of the communication asynchronous motor, and cannot be used as a variable frequency power supply. The entire circuit of the variable frequency power supply is composed of a ditch ...

Circuit breaker failure protection - Schneider Circuit breaker failure protection - Schneider

Circuit breaker failure maintenance refers to the relay maintenance action of faulty electrical equipment when the trip command is announced and the circuit breaker refuses, the maintenance action information of the faulty equipment and the current information of the rejected circuit breaker constitute the judgment of circuit breaker failure, and other related problems in the same plant and station are cut off in a shorter time limit.

The meaning of the inching of Schneider inverter The meaning of the inching of Schneider inverter

The inch movement in Schneider inverter means that the control signal can drive the motor intermittently according to the certain rules, and the motor acts in strict accordance with the dynamic and stop instructions of the control signal, and the motor does not roll by inertia during the shutdown. It's like moving an inch and then stopping. The full name of Schneider inverter is "...

Schneider EZD series molded case circuit breaker is recommended Schneider EZD series molded case circuit breaker is recommended

Create a high-quality circuit breaker for secondary power distribution EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution, especially suitable for secondary power distribution, civil construction market and mechanical and electrical market.

The comprehensive utility of the inverter control circuit - Schneider The comprehensive utility of the inverter control circuit - Schneider

(1) The operation circuit compares the external speed, torque and other instructions with the current and voltage signals of the detection circuit to determine the output voltage and frequency of the inverter. (2) The voltage and current detection circuit are the same as the main loop potential ...

Analysis of 10 reasons for frequent tripping of Schneider leakage switches Analysis of 10 reasons for frequent tripping of Schneider leakage switches

1. Defective device If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action. 2. Leakage switch with ...

The layout of the inverter is composed of Schneider The layout of the inverter is composed of Schneider

rectifier Many converters use diodes, which convert the power frequency power supply to DC power. It is also possible to form a reversible converter with two sets of transistor converters, because the purpose of the power target is reversible and can be regenerated for operation. Flat wave back After the rectifier rectification ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top