Solutions to Schneider drive fault codes

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

PHF: 1. The power supply of the inverter is not right or the fuse is blown; 2. There is a transient problem in a certain phase. 1. Check the power connection and fuse; 2. Reset.

USF: 1. Power supply voltage undervoltage; 2. Instantaneous voltage drop; 3. The load resistor is damaged. 1 Check the power supply voltage; 2 Replace the load resistor.

                                 Solutions to Schneider drive fault codes

OSF, OHF, OLF, ObF, OPF, LFF, OCF: the supply voltage is too high Check the supply voltage The heat sink temperature is too high Monitor the motor load; inverter ventilation; Wait for the inverter to cool down and then reset; Thermal maintenance tripping due to long overload time. 1 Check the thermal maintenance settings; Monitor motor load 2 Wait about 7 minutes before restarting Braking too fast or overloaded Extend the deceleration time, if necessary, add a braking resistor Output phase loss View

The 4 -2 0 mA signal of the AI2 port of the motor connection is lost: Look at the given circuit 1. The slope is too short; 2. The inertia is too large or the load is too heavy; 3. Mechanical card position. 1. Review the settings; 2. Check the motor/inverter/load capacity; 3. Check the condition of the mechanical part.

SCF C F: Short circuit or ground disconnect the inverter on the output side of the inverter. View the bridge resistance of the connecting cable and the motor insulated drive. 1. Fault with load relay control; 2. The load resistance is damaged, check the joints in the inverter as well as the load resistance.

SLF O F S F EEF InF: The inverter interface is incorrectly connected. Check the connection of the inverter interface, the motor overheating (PTC sensor), check the ventilation of the motor and the ambient temperature, check the type of sensor used, detect the load of the motor The connection between the sensor and the inverter is faulty, check the connection between the sensor and the inverter EEPROM memory fault, block the power supply of the inverter and reset. 1. Internal faults; 2. Interface Faults Check the interface of the inverter.

EPF SPF AnF: External linkage problem. Look at the faulty device and reset it, no speed response, and see the wiring and mechanical coupling of the speed sensor. 1. Don't follow the slope; 2. The speed is reversed to the set point. 1. Check the speed response settings and connection; 2. Check if the settings for a specific load are appropriate; 3. Look at the capacity of the motor-inverter, and whether a braking resistor is required.

SOF: 1. Unstable; 2. Heavy load. 1. View settings and parameters; 2. Add braking resistor; 3. Check the capacity of the motor/inverter/load.

CnF: Communication glitch in fieldbus. 1. Check the network connection of the inverter; 2. Check the timeout communication issues between the ILF palette and the dashboard Review the connection between the palette and the dashboard.

CFF: Faults that can arise after replacing the plates. 1. Nominal change of power board; 2. Changing the type of the palette, or installing the palette with the original no palette and the macro - equipped with CUS; 3. Removal of the option plate; 4. Inconsistent equipment cannot be saved. 1. Check the hardware equipment of the inverter (power or other); 2. Intercept the power supply of the inverter and reset; 3. Store the equipment in a file in the display module; 4. Press the ENT key twice to restore the factory settings (**When you press the ENT key twice, the following information will appear: Fact. Set? Is ENT/ESC a factory reset? ENT/ESC)

CFI: The equipment that is fed to the inverter through the serial port is inconsistent. 1. Check what equipment has been delivered; 2. Send an identical outfit.

More on that
The type of signal output from the Schneider sensor The type of signal output from the Schneider sensor

The type of sensor output signal Sensors are commonly used detection devices that convert perceived information into electrical signal outputs, and are used in a variety of applications. What can be divided into the output signal mode of the sensor ...

Schneider miniature circuit breaker problem analysis and answer Schneider miniature circuit breaker problem analysis and answer

Fault 1: The shell of Schneider MCB product is yellowed or burned. Reason 1: It is very likely that the magnetic coil inside the circuit breaker is burned out because of harmonics or high-frequency signals. Method 1: * The good thing is that the filtering can be satisfied with the use of 50Hz/60Hz power frequency. ...

The difference between an inverter and a servo drive – Schneider The difference between an inverter and a servo drive – Schneider

In terms of frequency converters: The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...

About the characteristics of Schneider explosion-proof inverter cabinet About the characteristics of Schneider explosion-proof inverter cabinet

1. Aluminum alloy shell or steel plate welding, surface spraying; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; 3. It mainly regulates ordinary three-phase by changing its output frequency ...

Frequency converter control motor leakage solution - Schneider Frequency converter control motor leakage solution - Schneider

Because the current at the input and output ends of the inverter contains high-frequency components, the leakage current formed by the high-frequency components when the inverter is driven is greater than that when the grid power supply is supplied. Because there are many varieties of circuit breakers, in some cases, even the inverter wires and motors ...

Introduction to Schneider limit switch series Introduction to Schneider limit switch series

1. XCKN compact limit switch Light and medium load use; Waist-shaped device holes for easy adjustment of mechanical errors; Bipolar isolation definitely disconnects the contacts; External waterproof sealing joint, the protection level is higher than that of rubber sleeve sealing pipe; Engineering plastic body, avoid temperature ...

Features of Schneider explosion-proof inverter boxes Features of Schneider explosion-proof inverter boxes

1. Aluminum alloy shell or steel plate welding, plastic spraying on the surface; 2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies; ​ 3. It mainly regulates the general three-phase difference by changing its output frequency.

Design and calculation method of inverter braking resistance - Schneider Design and calculation method of inverter braking resistance - Schneider

1. The number of braking resistor boxes is roughly calculated as: motor power (KW)/11.2 (take the upper limit of the integer). 2. The selection of the power of the braking unit is generally (1-2) times the power of the inverter; 3. The function of braking resistor ...

Schneider ATV32 inverter malfunction Schneider ATV32 inverter malfunction

1. The ATV32 inverter reports that the bLF is a brake control fault. Possible causes: 1. The brake release current is not reached. 2. When the braking logic control is assigned, only the closing frequency threshold [brake closure frequency] (bEn) is adjusted. Repair measures: 1. Check the inverter/electric ...

Schneider improves plant performance with automated control Schneider improves plant performance with automated control

1. Engineering planning one by oneWith data at their fingertips and intelligent and sensitive functions, engineers can easily plan and test equipment, improve process availability, and easily complete system integration together – ultimately reducing the planning time by up to 25%. ...

Schneider circuit breaker technical issues Schneider circuit breaker technical issues

1. Overload maintenance failure: The circuit breaker should be tripped for maintenance when the current exceeds the rated current, but sometimes the overload maintenance failure may be due to some reasons. This may be due to incorrect overload maintenance settings, long overload periods, thermal aging due to successive overloads, etc. 2 ...

Schneider introduces the new Lexium28S servo Schneider introduces the new Lexium28S servo

The newly launched Lexium28S Sercos III bus servo with BCH2 servo motor is available as a pre-order product portfolio to meet the needs of motion control and optimize the function of the machine. Lexium28S servo drives, available in 4 sizes, 10 models, power mask 0.05KW to 4 ...

Schneider ATV312 inverter failure Schneider ATV312 inverter failure

1. OLF is motor overload. Possible reasons: 1. Triggered by high motor current. 2. The value of the [cold stator resistance] (rSC) parameter is wrong. Corrective measures: 1. Check the [Motor Thermal Current] (ItH) setting of the motor thermal maintenance function and check the motor load. Wait...

The difference between Schneider and Siemens PLC The difference between Schneider and Siemens PLC

There are three main differences, namely: different uses, different products, and different characteristics. 1. Different use cases: The programmable manipulator produced by Siemens in Germany is also widely used in China, and has been used in metallurgy, chemical industry, printing production lines and other fields.

Schneider inverter external potentiometer connection Schneider inverter external potentiometer connection

The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal. The red thread is attached to the blackhead and inserted in a small hole. Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI. ...

The contents of the daily inspection of Schneider inverters The contents of the daily inspection of Schneider inverters

1) Whether the ambient temperature is normal or not, it is required to be in the range of -10-+40 °C, and it is better to be about 25 °C. whether the humidity meets the requirements, and whether the ventilation and heat dissipation of doors and windows are outstanding; Whether the lower air inlet and upper air outlet of the inverter are dusty or blocked due to excessive dust. ...

Detailed explanation of the steps of Schneider inverter inverter setup Detailed explanation of the steps of Schneider inverter inverter setup

1. Macro equipment: In view of the control requirements of different loads, Schneider inverters have talked about the macro equipment in advance and the initial function of the I/O terminals. Changes to the macro rig can be corrected under the Abbreviated Boot Menu. If required, it is also possible to re-equip the end separately ...

Schneider UPS uninterruptible power supply debugging precautions Schneider UPS uninterruptible power supply debugging precautions

1. Check whether all switches are in the disconnected position; 2. Check whether there are foreign objects in the UPS uninterruptible power supply cabinet and transformer; Check whether the flat cable connection is correct and whether it is loose; 3. Check that the connected plug is ...

Anti-electromagnetic interference method - Schneider Anti-electromagnetic interference method - Schneider

There are three main sources of electromagnetic disturbance to the industrial system: first, space field disturbance, which enters the system through electromagnetic wave radiation; the second is power disturbance, which directly damages the system; The third is the signal disturbance channel, which enters the system through the front and rear channels connected to the host. In order to ensure that the instrumentation ...

Schneider inverter series at a glance Schneider inverter series at a glance

1. ATV11 series The Schneider ATV11 series is primarily used in three-phase asynchronous motor inverters with a power range of 0.18 to 2.2 kW. 2. ATV12 series ATV12 Schneider inverter for power scale 0.18k...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top