Schneider Barrier Features: First of all, Schneider Barrier Switch can be used to block the power supply, it is able to disconnect the live equipment from the high-voltage maintenance equipment, and it can also see a significant disconnection point on it. Secondly, the Schneider barrier switch can cooperate with the circuit breaker to achieve the purpose of changing the wiring mode of the system operation. Schneider block switches turn small current circuits on or off. In the high-voltage power distribution equipment, the barrier switch is used more, which can well ensure the safety of maintenance work.
Regarding the operation method of Schneider barrier switch, here Kexu editor will answer for you. It is divided into 3 parts. It includes the operation method when the barrier switch is closed, the barrier switch is opened, and the barrier switch with electromagnetic locking fails.
When performing the reverse operation, the operator must carefully check the true disconnection position of the circuit breaker. Regarding the three-phase linkage barrier switch, the three-phase rise and fall should be at the same time, and the difference should not be greater than 3mm, so that the blocking switch can be opened and closed.
1. Barrier switch closing operation method
If it is a manual operation, the operator should first dial out the interlocking pin and then close, the beginning should be slow, and when the moving contact is close to the static contact, it should be closed quickly to prevent arc light. If the arc is generated at the beginning of closing, the barrier switch should be closed immediately, and the operator is prohibited from pulling the barrier switch back, because the pullback will expand the arc light and cause further damage to the equipment. At the end of closing, the force should not be too strong to prevent the closing from being too deep and causing damage to the supporting porcelain bottle. After the barrier switch is closed, the operator should carefully check whether the closing is outstanding and whether the moving contact has completely entered the static contact, so as to prevent the dynamic and static contact from heating due to poor touch. With regard to the reversing barrier switch on the rotating shaft, the blade should be placed on the plane of the vertically fixed contact after closing, so as to ensure the pressure at the contact and the necessary touch resistance; For casement barrier switches, the blade should be turned to a horizontal position after closing, and its arm should be straightened. If the movable cap of the static contact is on the right, it means that the hammer rod of the moving contact arm is too closed.
When operating the field barrier switch in winter, the frozen ice and frost and snow on the contact can be rubbed off by several times of connection and disconnection, so that the barrier switch can ensure that the dynamic and static contacts are excellent after closing. The condition for the reliable operation of the barrier switch is that when the barrier switch has transmission equipment, it should be ensured by its correct adjustment; If there is no transmission equipment, the correct operation of the insulating rod should be ensured. Barrier switches of various specifications are not promised to fall automatically in the event of a short circuit, so the barrier switch should be locked with five anti-locking equipment when closing the azimuth. The personnel on duty need to carefully check these equipment, buckle the blocking switch with a pin after each blocking switch is closed, and lock the five-proof blocking equipment to prevent the blocking switch from automatically disconnecting and forming an incident.
2. Operation method of barrier switch opening
When the moving contact leaves the static contact, if an arc is generated, the operator should immediately close the barrier switch and stop the operation. However, when blocking the small load current and charging current, the arc will be generated when the blocking switch is opened, and the blocking switch should be disconnected quickly in order to eliminate the arc smoothly. At the end of the brake, it should be slow, this is to prevent the impact force on the damage to the supporting porcelain bottle and the operating tissue, * after the operation personnel should check whether the interlocking pin is sold well. After the barrier switch is opened, the operator should carefully check the true disconnection direction of the barrier switch, the air insulation distance of the disconnection should be qualified, and check that the moving contact has indeed been pulled to the end, and the point of view of the swing should meet the requirements of the manufacturer. Regarding the indoor barrier switch, if the disconnected insulation distance is not good, the insulating partition should be pierced, otherwise there will be a discharge short circuit incident between the live side and the side of the ground wire hanging in the power failure.
|
More on that
|
Schneider Category VI unshielded RJ45 information module
Product Introduction
compose
1. RJ45 module body, 8 IDC contact pins
2. Crimping module
3. Back cover 7751S (optional)
Operating temperature range
-40°C to +70°C (65°C for non-stop use)
...
|
|
Schneider low-voltage circuit breaker selection method
1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the short-circuit current breaking ability of Schneider frame circuit breaker is larger and larger than that of device type. Usually, the branch line chooses ...
|
|
Schneider instrumentation maintenance precautions
1. When assembling and adjusting the appearance, the original position should be recorded for rehabilitation.
2. When repairing the appearance of precision instruments, if you accidentally bounce small parts away, you should first determine the position where you can fly down.
|
|
Schneider inverter ATV310 instruction with given
The instructions of the inverter are given with the given
conf→400-
→ 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...
|
|
Measures to reduce the interference of Schneider inverters themselves
(1) Add inductance and capacitance on the input side of Schneider inverter to form an LC filtering network
(2) The power cord of the Schneider inverter is supplied directly from the transformer side.
(3) If conditions permit, a separate ...
|
|
Schneider disconnector operation inspection content and requirements
(1) Whether the closing of the barrier switch is defective, whether there is no failure or dislocation;
(2) The porcelain insulation of the barrier switch should be free of cracks, discharge phenomena and flashover traces;
(3), contact viewing: a, view ...
|
|
Schneider PLC failure steps
(1) If the signal is controlled on a counter, first look at the logic that controls the reset, then the counter signal. Follow steps 2 to 5 above.
(2) If Schneider PLC aborts in some places where the output is encouraged, generally in the middle of the situation, then look for the next step ...
|
|
Schneider ATS48 soft starter issue
1. What type of ATS48 power supply is?
The control power supply of ATS48 selects communication input, and supplies power to the controller, input and output ports through internal power processing;
The control power supply of Q series products is 220V-415V;
Handling of the Y-Series ...
|
|
Schneider inverter ATV32 book type performance and advantages
Schneider ATV32 book inverter has built-in programmable controller function, flexible and intelligent; Integrated safety functions, 30% cost savings compared with external security modules; First-class Schneider patented synchronous motor open-loop control technology; Book-type design, support side-by-side installation, space-saving; Many...
|
|
Schneider miniature circuit breaker model and parameter difference
Schneider miniature circuit breakers are commonly used in C65, C120, EA9, INT125 and other products.
Parameter differences:
N -------- breaking ability, N is 6000A, H is 10000A, L is 15kA
...
|
|
The difference between Schneider and Siemens PLC
There are three main differences, namely: different uses, different products, and different characteristics.
1. Different use cases: The programmable manipulator produced by Siemens in Germany is also widely used in China, and has been used in metallurgy, chemical industry, printing production lines and other fields.
|
|
Schneider Electric has announced the launch of its Pacific Foundation
Schneider Electric has announced the launch of its Pacific Foundation, which will provide financial and advisory support to charitable foundations in the Pacific region to address fundamental human rights issues of access to energy. Four foundations were selected as the Foundation's initial recipients.
|
|
Knowledge of Schneider Lexium32 servo motors
Schneider Lexium32 servo motor new generation servo release enriches Schneider Electric's high-end product line, its outstanding product functions, sensitive openness and user-friendly planning will better meet the high functional and safety requirements of industrial customers. In China's industrial production is increasingly moving towards energy-saving ...
|
|
Schneider inverter has misunderstandings in practical applications
Myth 1: Whether the inverter can complete power saving
The use of inverters can save electricity Some literature claims that inverters are power-saving control products, giving people the impression that only the use of inverters can save electricity. In practice,
The reason why the inverter can save electricity is because it can ...
|
|
How to prevent counterfeiting from Schneider switch sockets
1. Logo
The logo of the product is a status symbol, so it will be made very exquisitely. Schneider switches are also very careful in the production of logo, each letter is like an independent work of art, and let's see that the letter "A" is flat and wide. But the imitation ...
|
|
Power wiring requirements for Schneider PLC
The power supply of the DPLC should be taken from the trunk line with a relatively stable voltage or the special line led by the bus of the substation to ensure the voltage quality of the PLC. If the voltage fluctuates too much, consider installing a voltage regulator or uninterruptible power supply (UPS). 2. The power cord is best to use twisted pair, and its cross-sectional area should not be less than 2 square millimeters.
|
|
Automatic control instrument construction content and procedures - Schneider
1. Construction preparation. Including the preparation of operating conditions (construction skills documents and detailed planning documents), construction organization planning, equipment list, data budget, and list of machined parts;
2. Cooperate with civil engineering majors to do a good job of embedding, ...
|
|
Schneider UPS power supply common fault analysis
1. When there is mains power, the UPS output is normal, and when there is no mains power, the buzzer beeps for a long time and there is no output
Fault analysis: From the phenomenon to identify some problems of the battery and inverter, you can view it according to the following procedures:
1. Check the battery voltage to see if the battery is undercharged.
|
|
Inverter fault repair - Schneider
To repair the output board driven by the inverter, we must first investigate whether the components on the PCB board are burned out, replace them first, and then analyze what causes the burned out and deal with this problem.
And then...
|
|
The difference between an inverter and a servo drive – Schneider
In terms of frequency converters:
The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...
|
|