1. Shell current and rated current
The size of the shell current is 100 (rated current 16 25 32 40 63 80 100) 250 (rated current 160 250 400 (rated current 250 400) 630 (rated current 630A.)
2. Segmentation talents
N ------- breaking ability, F is 36KA N, N is 50KA H is 70KA L is 100KA
3. Trip unit
TMD -------- trip actuator, with TMD-Thermomagnetic Trip MIC2.2 MIC5.2A 5.2E 6.2A 6.2E electronic tripper
4. Number of poles
The number of poles ------ 3P3D has 3P2D, 3P3D, 4P3D, 4P4D
|
More on that
|
Precautions for false load connection in Schneider inverter debugging
There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...
|
|
The inverter has a problem supplying power to the motor – Schneider
A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.
The inverter is a supporting operation with the inverter motor.
|
|
How to choose a Schneider circuit breaker?
First, calculate the value of the current of each branch
(1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...
|
|
Frequency converter and PLC connection problems - Schneider
When the inverter is used to form an automatic control system for control, in many cases, the PLC and the inverter are used together, and how to correctly connect the PLC and the inverter together has become the key to the success of the system.
1.PLC switch ...
|
|
Frequency characteristics of frequency converters – Schneider
a. Output frequency scale. The output frequency scale that can be controlled by the general inverter is generally 0.1Hz, and the highest frequency is different according to the functional indicators of the inverter, generally 400Hz, and some models are 650Hz. No matter how high the output frequency is, it belongs to the scale of high-frequency inverter.
...
|
|
About the characteristics of Schneider explosion-proof inverter cabinet
1. Aluminum alloy shell or steel plate welding, surface spraying;
2. Built-in inverters, circuit breakers, signal lights and other components produced by domestic or Schneider and other companies;
3. It mainly regulates ordinary three-phase by changing its output frequency ...
|
|
Schneider ATV630 VFD series advantages
Depending on the customer's requirements, wall-mounted drives, built-in cabinets and floor-mounted free-standing solutions in protection classes IP 21, IP 23, IP 54 and IP 55 are available.
Thanks to the built-in pump monitoring function, the device reacts immediately when pump efficiency drops, resulting in ...
|
|
Schneider instruments measure error factors
When measuring, because various elements will constitute a small number of errors, these elements need to be understood and effectively solved, so that the errors in the whole measurement process can be reduced to the smallest. When measuring, the main errors that constitute errors are system errors and random errors, and system errors have the following conditions: misreading, ...
|
|
Introduction of Schneider Electric three-phase uninterruptible power supply
Sensitive operation form, satisfactory business operation policy:
Four-level inverter technology: Galaxy VX uses innovative patented four-level inverter technology to reduce power consumption and pressure on power components, and complete the perfect unity of high power and component reliability.
Sensitive operating form ...
|
|
How to distinguish the authenticity of Schneider products
One. QR code scanning
Mainly for low-voltage power distribution and industrial control products produced from September 25, 2013
Method: Scan the QR code on the left side of the product anti-counterfeiting label to enter the self-service inquiry channel
Two. The official website ...
|
|
Schneider ATV71 selection and letter meaning
The type of Schneider inverter generally reflects the rated voltage, rated power, and load requirements of the inverter (heavy or light load).
Here are two examples:
Example 1:
Schneider Inverter Type: ATV71HD11N ...
|
|
Schneider diode selection experience and substitution method
1. Selection of detection diode
Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...
|
|
MiCOM P5 Series Intelligent Relay Protection Device P5 Series New Product: P5T30
MiCOM P5 Series Intelligent Relay Protection Device P5 Series New Products: P5T30 Schneider Electric Powerlogic P5 Series Transformer Differential Protection New Product P5T30 improves the gap in the differential protection of motor generators in the P5 series, making the P5 series more widely applicable.
In appearance, mechanical ...
|
|
Key points of maintenance of Schneider battery
(1) Insulating pads should be arranged in the maintenance channel of the battery pack.
(2) It is strictly forbidden to use batteries of different manufacturers, different capacities and different models in the same system.
(3) VRLA batteries do not need to be charged for the first time before use, but should be recharged. Replenish the charge ...
|
|
Analysis of 10 reasons for frequent tripping of Schneider leakage switches
1. Defective device
If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action.
2. Leakage switch with ...
|
|
Schneider PLC series features
Schneider TSX08 series NEZA PLC
It is a small PLC with abundant functions, small size, strong general-purpose type, and high cost performance.
NEZA series adopts a new generation of handheld programmer, and the operating system adopts PL707-WinCE to support Chinese interface. In the process of use, whether it is ...
|
|
Schneider inverter enters the parameter setting method
1. The first step is to check whether the inverter is connected to the line, and whether the wiring of the control line and the power circuit is correct
2. Next, turn on the power of the inverter, enter the motor parameters, and perform motor identification
3. Next, set the function parameters to launch the ...
|
|
Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award
Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.
|
|
Schneider selection of different types of circuit breakers
Miniature circuit breakers are: A9 (iC65, iDPN, etc.), M9 (C65, DPN, C120, NG125, etc.), E9, OSMC32N/OSMC65H, etc.
Molded case circuit breakers are: NSX, NSE, EZD, NSC, large molded case NS.
Structural circuit breakers include: MT, MTE, etc.
...
|
|
Schneider circuit breaker maintenance method
1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences:
(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the effect of arcing, destroying the insulation between the fractures after the main contact is broken, which is difficult to arc or arc re-ignition, and in severe cases, arc extinguishing will be formed.
|
|