MiCOM P5 Series Intelligent Relay Protection Device P5 Series New Products: P5T30 Schneider Electric Powerlogic P5 Series Transformer Differential Protection New Product P5T30 improves the gap in the differential protection of motor generators in the P5 series, making the P5 series more widely applicable.
In terms of appearance, mechanical characteristics, number of I/O, communication capability, and control functions, the P5T30 is the same as the P5F30. Different from P5F30, P5T30 supports 8 groups of CT, 1 group of VT, and has some more transformer protection functions: transformer differential protection, non-electric power protection, and over-excitation protection. Its differential action time is less than 30ms. P5T30 is suitable for medium size double winding transformers (35kv/10kv, 110kv/35kv).
Transformer Differential Protection:
Scenario: The transformer will have a serious impact on the power system due to short-circuit fault or abnormal current damage, and differential protection can be effectively prevented as the main protection.
Overexcitation Protection:
Scenario: The transformer will be overexcited due to the increase of voltage or frequency decrease, the core of the belt will be saturated, the excitation current will increase sharply, the excitation current waveform will be distorted, and the higher harmonics will be generated, which will increase the internal loss and increase the temperature of the core, and in severe cases, cause the core to deform and damage the dielectric insulation.
The advantage of the P5T30 is that it has the excellent basic configuration of the P5 and the powerful transformer protection function, which is a cost-effective transformer differential protection device.
|
More on that
|
Schneider inverter debugging steps and brief description
Commissioning process of the Schneider 61 series
1. Preparations
1. Measure insulation. Connect the power supply side (R.S.T) and the motor side (U.V.W) of the inverter
Disconnect the cable, insulate the cable with a 500 megaohm or 1000 megaohm shake meter, and if it meets the requirements, restore it.
|
|
Schneider EZD series molded case circuit breaker is recommended
Create a high-quality circuit breaker for secondary power distribution
EZD molded case circuit breaker is a product series of molded case circuit breakers specially designed for secondary power distribution, especially suitable for secondary power distribution, civil construction market and mechanical and electrical market.
|
|
Pay attention to the problem when using UPS power supply - Schneider
1. The parameters set in the host cannot be changed at will during use. In particular, the parameters of the battery pack will directly affect the service life. With the change of ambient temperature, the float charge voltage should be adjusted accordingly. Generally, 25 °C is the standard, and when the ambient temperature rises or falls by 1 °C, the float charge ...
|
|
The inverter controls the speed of the AC motor – Schneider
Most of the motors used in the industry are of this type. The rotational speed of an induction AC motor (henceforth referred to as a motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed by the working principle of the motor. Since the pole ...
|
|
Precautions for the use of Schneider AC contactors
There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A
When installing, it should be in accordance with the regulations...
|
|
Instrumentation mechanical equipment system - Schneider
1. Power system:
The wire and cable products selected in the power system mainly include overhead bare wires, busbars (busbars), power cables (plastic cables, oil-paper power cables (fundamentally replaced by plastic power cables), rubber cables, overhead insulated cables), branch cables (replacing part of the busbars), ...
|
|
Schneider Instrumentation Classification
1. Industrial automation appearance and control system. This is generally referred to as PA, FA in foreign countries. PA is called process automation, and FA is called factory automation. The appearance and control system used in process automation and factory automation belong to this category, and some parts of the appearance of analytical instruments and electrical instruments also belong to the ...
|
|
Schneider instrumentation maintenance precautions
1. When installing and adjusting the appearance, the original status should be recorded for rehabilitation.
2. When repairing the appearance of fine instruments, if you accidentally bounce small parts away, you should first determine the direction where you can fly.
|
|
Introduction of Schneider Electric three-phase uninterruptible power supply
Sensitive operation form, satisfactory business operation policy:
Four-level inverter technology: Galaxy VX uses innovative patented four-level inverter technology to reduce power consumption and pressure on power components, and complete the perfect unity of high power and component reliability.
Sensitive operating form ...
|
|
How to operate the transformer DC resistance tester – Schneider
1. The instrument test has a total of YN winding three-phase test, YN winding three-phase phase-by-phase test, low-voltage winding magnetization method test of iron-core five-column low-voltage angular transformer, low-voltage winding phase selection test and general four-terminal method of ironcore three-column low-voltage angular transformer.
...
|
|
Schneider AC contactor precautions
There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A
When installing, it should be in accordance with the regulations...
|
|
Schneider XPS safety control module selection method
(1) Evaluate the safety control level that the machinery and equipment need to reach
(2) Confirm the type of input signal to be monitored
and (3) the number of input signals that need to be monitored
(4) The number and type of channels that the module needs to output
(5) Whether it is necessary to control the output device (such as ...
|
|
Schneider Multi9 Series C120 FAQs
1. What are the characteristic curves of Schneider Multi9 series C120L?
A: C/D curve.
2. What is the rated current level of Schneider Multi9 series C120?
A: 63A, 80A, 100A, 125A.
3. Shi ...
|
|
Turbine flowmeter selection factor - Schneider
Turbine flowmeter is a kind of speed appearance, it has high precision, good repeatability, no zero drift, high range ratio, simple structure, few moving parts, high pressure resistance, wide measurement scale, small size, light weight, small pressure loss, convenient repair and other advantages, turbine flowmeter has high quality ...
|
|
Schneider ATV32 inverter malfunction
1. The ATV32 inverter reports that the bLF is a brake control fault.
Possible causes: 1. The brake release current is not reached. 2. When the braking logic control is assigned, only the closing frequency threshold [brake closure frequency] (bEn) is adjusted.
Repair measures: 1. Check the inverter/electric ...
|
|
Schneider PLC signal light meaning
Take the Schneider PLC with model number TWDLCAA40DRF as an example:
The first PWR: is the meaning of power supply;
The second RUN: is the PLC operation indicator; Long dark: The application is not fulfilling; Shine: The controller is in a stay or a mistake in performance; Solid on: The controller is in operation ...
|
|
Schneider inverter external potentiometer connection
The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal.
The red thread is attached to the blackhead and inserted in a small hole.
Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI.
...
|
|
Switching power supply circuit fault phenomenon - Schneider
1. The power supply voltage of the secondary load is 0V. There is no response after the inverter is powered on, there is no indication on the operation display panel, and the 24V and 10V voltages of the measurement and control terminals are 0V. Check that the charging resistance or pre-charging circuit of the main circuit is correct, which can be identified as a switching power supply fault. The overhaul process is as follows:
1 ...
|
|
Schneider TRSS telemetry system solution
Schneider Electric provides safe, reliable, end-to-end telemetry solutions to help you meet the challenges of long-distance operations. With an outstanding reputation in the fields of appearance, manipulation and data collection, wireless communications, IT, and other industries and common sense, Schneider Electric telemetry system solutions can help ...
|
|
Schneider inverter maintenance power settings, waveform test problems
1. After the inverter is repaired, the power number needs to be modified, don't forget it
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|