Schneider ATV630 VFD series advantages

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Depending on the customer's requirements, wall-mounted drives, built-in cabinets and floor-mounted free-standing solutions in protection classes IP 21, IP 23, IP 54 and IP 55 are available.

Thanks to the built-in pump monitoring function, the device reacts immediately when pump efficiency drops, making it useful to monitor your production processes.

Tell critical operating points without the need for additional sensors.

Build a production process that integrates pressure, flow, and level control, including compensation for flow loss.

                               Schneider ATV630 VFD series advantages

The innovative "Stop & Go" abort function provides up to 60% energy savings in standby mode.

In addition, the device has a data recording function and can display the power consumption graphically.

The Altivar ATV630 from Schneider comes with an Ethernet-based embedded web server interface that allows you to monitor your production process with your daily work tools.

Users can access energy consumption data locally and remotely, and self-defined dashboards mean you can check your energy consumption anytime, anywhere using your computer, tablet or smartphone.

These devices are user-friendly and easy to integrate with standardized FDT/DTM and ODVA skills and powered by the Unity Pro library of Pre-Bounds.

It can be easily accessed via a computer, tablet or smartphone and securely connected via "Ethernet for Security".

Modular planning is adopted, with a proven service concept, which makes it easy to organize spare parts logistics.

Integrated monitoring monitors individual components, allowing flexibility in organizing protection plans and optimizing protection costs.

Power modules and fans are super simple to replace.

With a dynamic QR code and customer service app, support is available quickly.

More on that
Maintenance and overhaul of frequency converters and soft starters Maintenance and overhaul of frequency converters and soft starters

The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.

Fault check steps for frequency converters - Schneider frequency converters Fault check steps for frequency converters - Schneider frequency converters

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...

Heat dissipation strategy for frequency converters – Schneider Heat dissipation strategy for frequency converters – Schneider

Drives power and operate commercial and industrial motors, and thermal protection is necessary in accordance with their planning and operating environment. The main advantages of the frequency converters are flexible handling, smooth start-up and shutdown functions, and significant energy savings due to centrifugal fans and pumps operating under variable loads. ...

Measures to reduce the interference of Schneider inverters themselves Measures to reduce the interference of Schneider inverters themselves

(1) Add inductance and capacitance on the input side of Schneider inverter to form an LC filtering network (2) The power cord of the Schneider inverter is supplied directly from the transformer side. (3) If conditions permit, a separate ...

Whether an AC circuit breaker can be used in a DC circuit Whether an AC circuit breaker can be used in a DC circuit

Schneider circuit breakers are used to open and break communication loops. The arc extinguishing of the communication system is simple, but the arc extinguishing of the DC system is more difficult. Because the system is different and the arc extinguishing principle is different, there is a big difference in structure and performance between the communication circuit breaker and the DC circuit breaker. Compared with the communication circuit breaker, the DC circuit breaker ...

Schneider Electric has announced a partnership with RMSI Schneider Electric has announced a partnership with RMSI

Schneider Electric has named RMSI North America, an IT services company that provides geospatial and software solutions, as an ArcFM Specialty Partner. RMSI is well positioned to provide GIS solutions for utilities and telecommunications companies across the entire geospatial value chain...

Schneider PLC failure steps Schneider PLC failure steps

(1) If the signal is controlled on a counter, first look at the logic that controls the reset, then the counter signal. Follow steps 2 to 5 above. (2) If Schneider PLC aborts in some places where the output is encouraged, generally in the middle of the situation, then look for the next step ...

How to choose the right inverter for the motor? How to choose the right inverter for the motor?

The inverter is an electric transmission element that is used in frequency conversion skills and microelectronics skills to control and communicate with the motor by changing the frequency and fluctuation of the power supply of the motor. The birth of the inverter cabinet originated from the communication motor ...

Key points of operation of Schneider disconnectors Key points of operation of Schneider disconnectors

Features of Schneider Barrier Switch: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and can also see the obvious disconnection point on it. Secondly, Schneider barrier switches can cooperate with circuit breakers to change the operation of the system.

The control mode of low-voltage inverter - Schneider The control mode of low-voltage inverter - Schneider

From the perspective of skills alone, the control method of the low-voltage inverter also indicates its skill portal to a certain extent. Here, we've broken down the following manipulation methods: 1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by the simple structure of the control circuit, the cost of ...

How Schneider contactors work How Schneider contactors work

1. Contactor refers to an electrical appliance that uses a coil to flow through an electric current to generate a magnetic field, so that the contact is closed, and then the load can be controlled. Because it can quickly block the main circuit and frequently connect the equipment with high-current control circuits, it has been widely used in electrical engineering.

Schneider inverter ATV310 instruction with given Schneider inverter ATV310 instruction with given

The instructions of the inverter are given with the given conf→400- → 401 (given channel), → 01 (given analog terminal), 163 (given by remote display terminal), 164 (given by mudobus communication), 183 (navigation knob ...

Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award Two of Schneider's low-voltage power distribution products won the Germany Red Dot Award

Beijing, China, April 6, 2022 – Recently, the list of "Red Dot Planning Awards", known as one of the world's three cutting-edge industrial planning awards, was grandly announced in Germany.

Schneider inverter frequently asked questions Schneider inverter frequently asked questions

1. Schneider inverter uses analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA? Answer: Because of the large output frequency parameter "TFR" of the inverter, the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is ...

Schneider UPS power supply common fault analysis Schneider UPS power supply common fault analysis

1. When there is mains power, the UPS output is normal, and when there is no mains power, the buzzer beeps for a long time and there is no output Fault analysis: From the phenomenon to identify some problems of the battery and inverter, you can view it according to the following procedures: 1. Check the battery voltage to see if the battery is undercharged.

The difference between an inverter and a servo drive – Schneider The difference between an inverter and a servo drive – Schneider

In terms of frequency converters: The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...

Schneider touch screen touch deviation causes Schneider touch screen touch deviation causes

(1) Problem 1: Contact deviation Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye when checking the alignment. Deal 1: Correct the position from the beginning. Phenomenon 2: ...

Schneider diode selection experience and substitution method Schneider diode selection experience and substitution method

1. Selection of detection diode Point-contact germanium diodes are generally used for detection diodes, such as 2AP series. When selecting, the detection diode with high operating frequency, small reverse current and large forward current should be selected according to the specific requirements of the circuit. Although the detection and rectification of ...

The difference between vector and general use of inverter - Schneider The difference between vector and general use of inverter - Schneider

1. The control accuracy of the vector type is higher than that of the general-purpose type. 2. The vector type has a large output torque at low speed, which can make the motor get a larger starting torque, which is suitable for application in the occasion of heavy load starting, such as: high-power long belt, hoist, etc. If used in some of the more common fields ...

Schneider low-voltage circuit breaker selection method Schneider low-voltage circuit breaker selection method

1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the short-circuit current breaking ability of Schneider frame circuit breaker is larger and larger than that of device type. Usually, the branch line chooses ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top