1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences:

(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the effect of arcing, and the insulation between the fractures after the main contact is broken is destroyed, which is difficult to arc or arc re-ignition, and in severe cases, the arc extinguishing chamber will burst.

(2) The insulation strength of the supporting porcelain bottle and the arc extinguishing chamber is reduced, and the discharge along the surface is formed.

(3) Foreign objects such as patent leather and rust slag in the pipeline may block the air port, causing the main circuit breaker to malfunction and cause the phenomenon of jamming.

(4) If the foreign matter enters the arc extinguishing chamber, it may form a poor contact of the main contact, which will cause the nonlinear resistance to burn due to long-term energization, and in severe cases, the nonlinear resistance will be formed and the porcelain bottle will burst.

Therefore, an oil-water separator is installed on the inlet pipe of the main circuit breaker air storage cylinder, and there is a water discharge valve at the lower part, and the water should be drained regularly during operation and maintenance to insist on the clean air circuit.

2. Replace rubber parts regularly

The main circuit breaker is a kind of pneumatic and electrical structure with messy structure, and each component has high requirements for sealing function, so in order to ensure outstanding sealing function, rubber parts should be replaced regularly.

                               Schneider circuit breaker maintenance method

3. Check the main components regularly

Each primary component should be regularly reviewed to maintain the outstanding skill status.

(1) Arc extinguisher

The dynamic and static contacts will be worn out due to the conflict between the dynamic and static contacts due to the frequency of division and combination, so as to reduce the overtravel and reduce the contact pressure. When the overtravel is reduced to a certain extent, the dynamic and static contacts should be replaced. When the deformation of the moving contact recovery tension spring exceeds a certain limit, it is necessary to replace it in time.

(2) Nonlinear resistance

Adhere to the internal control and cleaning of nonlinear resistance porcelain bottles, excellent sealing, and regularly replace the desiccant in nonlinear resistance porcelain bottles. Detect the resistance value of the nonlinear resistor, and when the resistance value changes beyond a certain limit, it is necessary to replace it in time.

(3) Main valve

Check the size of the cooperation between the piston and the valve body regularly, and replace it in time if the size does not meet the requirements.

(4) Transmission air cylinder

Properly adjust the buffer of the transmission air cylinder to ensure that the disconnector operation is excellent. Check the accuracy of the cooperation between the piston and the cylinder block at regular intervals, and ensure its outstanding operation by trimming or replacing parts.

(5) Ventilation plug door

It is necessary to replace the packing material in the plug door regularly, check the ventilation volume of the plug door, and adjust it to the promised range.

1. Voltage quick break maintenance

When the line is short-circuited, the bus voltage drops sharply, and when the voltage drops to the voltage maintenance setting value, the low-voltage relay acts, jumps the circuit breaker, and instantly removes the fault. This is called voltage quick break maintenance.

Second, the current quick break maintenance

Current quick break maintenance is divided into no time limit current quick break and time limited current quick break, when the line presents a problem, no time limit quick break maintenance can act instantaneously, but it can only be a part of the line, with time limit current quick break maintenance can maintain the whole line in addition to the time limit speed break maintenance is a time limit difference greater than the next level of line no time limit maintenance, so when the first end of the next section of the line is short circuit, the maintenance will not be misoperated.

3. Differential quick-break maintenance of transformer

Differential maintenance is the main maintenance of the transformer, which is installed according to the principle of circulating current.

It is mainly used to maintain various interphase short circuit faults that occur inside the winding of double or triple winding transformer windings and their lead wires, and can also be used to maintain transformer single-phase inter-turn short circuit faults.

Differential quick-break maintenance, in order to prevent the differential maintenance from being rejected due to the addition of high-order harmonics that occur when the current transformer is full at a high short-circuit current level, and a large braking torque occurs; When the short-circuit current reaches 4-10 times the rated current, the quick-break component is quickly exported

Differential maintenance is very useful and can instantly remove the entire line of faults, and is generally only used for component maintenance, such as transformers and generators. The principle is to compare the magnitude and direction of the current on both sides of the element.

Current quick break maintenance reflects the problem of interphase short circuit, and is widely used in 10-35KV distribution lines and small-capacity transformers. Its action current is set according to the short-circuit current, the value is large, as long as the short-circuit current at the beginning of the line will be greater than its action current, that is, the quick-break maintenance will act, so its maintenance scope is limited to the first part of the line.

The function of the time-limited quick break:

The MGK31C recloser controller is an outdoor controller specially designed for ZW □ permanent magnet switches of medium voltage 35kV and below. It can be convenient to cooperate with the permanent magnet switch on the column to realize the management of opening and closing... Line maintenance function ̈ Overcurrent I.Section: Quick break maintenance function ̈ Overcurrent II.Section: Time-limited quick-break maintenance ̈ Overcurrent III.Section: Time-limited overcurrent maintenance ̈ Active overlap

Overcurrent maintenance function:

Over-relay current maintenance appliances have overload, locked-rotor, overvoltage, undervoltage, phase failure, current unbalanced maintenance functions, overcurrent maintainers can be used for any type of three-phase motor for fast and reliable maintenance. The overcurrent maintainer has the characteristics of simple structure, easy to use, low price, no power consumption, long life and small size.

More on that
Common analysis method for electrical control line faults - Schneider Common analysis method for electrical control line faults - Schneider

1) Survey and research method. The investigation and research method is to understand the obvious problem phenomena through "seeing", "listening", "smelling", "touching" and "asking"; After visiting the operator, understand the cause of the failure; A common way to help find the fault point after asking others or consulting information ...

Schneider PLC control cabinet installation wiring method Schneider PLC control cabinet installation wiring method

(1) When placing signal cables with different properties into the same conduit, they must be isolated (2) Try to avoid accommodating multiple power cords in the same conduit. When it is necessary to set up, a partition should be placed inside the conduit and the partition should be grounded. ...

Inverter control motor speed method - Schneider Inverter control motor speed method - Schneider

1. Why can the rotation speed of the motor be changed freely? Motor rotation speed unit: r/min number of rotations per minute, can also be expressed as rpm. Example: 2-pole motor 50Hz 3000 [r/min] 4-pole motor 50Hz 1500 [r/min] Conclusion:...

Inverter selection principle - Schneider Inverter selection principle - Schneider

1. Select the inverter according to the load characteristics. 2. When selecting the inverter, the actual motor current value should be used as the basis for the selection of the inverter, and the additional power of the motor can only be used as a reference. Secondly, the output content of the inverter should be fully considered.

Factors influencing the differential thermal analysis of instrumentation - Schneider Factors influencing the differential thermal analysis of instrumentation - Schneider

The operation of differential thermal analysis is simple, but in practical work, it is often found that the same sample is measured on different instruments, or different measurements are measured on the same instrument, and the results of the differential thermal curve of industrial electrical appliances are different. The high temperature, shape, area, and size of the peaks will all change. ...

Schneider instrumentation winter insulation measures Schneider instrumentation winter insulation measures

The methods adopted usually are: selection, thermal insulation and heat tracing, protection (point inspection, sewage discharge) and so on. Selection method Choose the appearance of the type with insulation equipment. According to the category and use of the appearance and the geographical location of the proposed equipment, the insulation and antifreeze requirements of the appearance are proposed, and then submitted to the manufacturer for processing. ...

Schneider inverter and PLC connection problems Schneider inverter and PLC connection problems

When the inverter is used to form an automatic control system for control, in many cases, PLC and inverter are used together, and how to correctly connect the PLC and inverter together has become the key to the success of the system. 1.PLC switch ...

The ultimate short-circuit breaking capacity of Schneider circuit breakers The ultimate short-circuit breaking capacity of Schneider circuit breakers

The limit short-circuit breaking ability (ICU) refers to the short-circuit current that can be turned on and broken under certain experimental parameters (voltage, short-circuit current, power factor) and through a certain experimental procedure, and after this on-off, it will no longer continue to carry its rated current. It's experiments ...

Analysis of the causes of Schneider touch screen touch deviation Analysis of the causes of Schneider touch screen touch deviation

(1) Fault--: Contact error Phenomenon 1: The direction of the finger does not coincide with the mouse arrow. Reason 1: After installing the driver, there is no vertical contact with the bullseye center when correcting the bearing. Solution 1: Re-align the bearing. Phenomenon 2: Some districts ...

Precautions for trial operation of Schneider motors Precautions for trial operation of Schneider motors

1. Check during the test run of the motor 1.1 Before the motor starts It is necessary to carefully check whether the insulation resistance is qualified, check whether the wiring of the secondary circuit is correct, and the inside of the motor should be boring, clean and free of debris. Investigate whether the fastening bolts of the motor are loose and the bearing is ...

Schneider UPS power supply installation precautions Schneider UPS power supply installation precautions

The quality of UPS power supply devices directly affects the long-term operation of the UPS system in the future, especially the large and medium-sized UPS power supplies, so the large and medium-sized UPS power supplies should be standard in the process of planning to the device. Generally speaking, UPS power supply ...

Steps for wiring and installation of rotary encoders – Schneider Steps for wiring and installation of rotary encoders – Schneider

Rotary encoder to roll the output pulse, through the counting equipment to know its position (PLC) we usually use incremental encoders, the incremental encoder output pulse signal can be directly input to the PLC, the high-speed counter of the PLC to count its pulse signal, in order to obtain the ...

Schneider AC contactor precautions Schneider AC contactor precautions

There are many series of contactors: LC1-SK series: below 6ALC1-K series: 6A-16ALC1-D series: 9A-150ALC1-F series: 115A-800ALC1-B series: 750A-1800A When installing, it should be in accordance with the regulations...

Analysis of 10 reasons for frequent tripping of Schneider leakage switches Analysis of 10 reasons for frequent tripping of Schneider leakage switches

1. Defective device If the lead wire of each pile head is not firmly connected and loosened for a long time, it will cause the pile to heat and oxidize, burn out the outer insulation of the wire, and announce sparks and burnt smell, resulting in undervoltage of the line and air switch action. 2. Leakage switch with ...

Troubleshooting methods in electrical circuit control - Schneider Troubleshooting methods in electrical circuit control - Schneider

The troubleshooting method of the electrical control line is not the same as a thousand people, and various methods can be used cooperatively, but do not copy the rigid set. In general, investigative research can help us to find out the problem. The experimental method can not only find out the fault phenomenon, but also find the fault location or fault circuit; Logic...

Schneider low-voltage circuit breaker selection method Schneider low-voltage circuit breaker selection method

1. Determine the type and maintenance situation of Schneider circuit breaker according to the maintenance requirements of the line, and determine the selection of frame type, device type or current limiting type. Generally speaking, the short-circuit current breaking ability of Schneider frame circuit breaker is larger and larger than that of device type. Usually, the branch line chooses ...

The inverter has a problem supplying power to the motor – Schneider The inverter has a problem supplying power to the motor – Schneider

A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply. The inverter is a supporting operation with the inverter motor.

The form of power input and output - Schneider The form of power input and output - Schneider

1. Single-phase input/single-phase output: If the capacity is relatively small, the single-entry UPS hanging on any phase of the mains will not be troublesome to the three-way distribution balance of the mains, the load capacity is small, and the output line diameter (current value) of the single-phase output is not ...

Maintenance and overhaul of frequency converters and soft starters Maintenance and overhaul of frequency converters and soft starters

The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.

Pressure reducing valves in Schneider instrumentation Pressure reducing valves in Schneider instrumentation

A kind of pressure reducing valve in instrumentation refers to a device used to control the pressure value. Pressure reducing valves are usually used in water-related categories, because from the perspective of the transmission medium, the transmission medium of the equipment is mainly water, but we all know that water is a thing that will ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top