Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

A frequency converter is a device that converts power to other frequencies of power supply. The power frequency of our country is 50Hz, in the field of motors, in order to change the speed of the motor, or other performance changes, many motors choose inverter power supply.

Inverter is a kind of conversion equipment used with the inverter motor, from the equipment of the line, the inverter is between the motor and the power frequency power supply, and the motor with different load characteristics should match the inverter with different performance.

                               The inverter has a problem supplying power to the motor – Schneider

The relationship between the voltage and frequency of the inverter

In the case of an asynchronous motor, the torque of the motor is the result of the effect of the magnetic flux of the motor and the rotor current. When the frequency of the power supply is lowered, if the input voltage of the motor is kept unchanged, the magnetic flux of the motor will be full, which will cause the motor winding to burn in severe cases. Therefore, when reducing the frequency of the power supply, the input voltage of the motor should be lowered at the same time, and the magnetic flux of the motor should be controlled as the principle, which is generally used in the load of fans and pumps.

For power frequency motors, if the voltage is lower than the additional voltage, the current of the motor will increase a lot if the same power is output, especially for the motor running on the temporary line, and the winding incineration problem caused by this is particularly large. Then about the motor powered by the inverter, when running at low speed, if the same power is required to be output, that is, the constant power operation condition, there is the same problem of increasing the current, but if it is a constant torque operation condition, the current of the motor will not change much.

The control key of the 60Hz motor is the power frequency 50Hz power supply experiment

Regarding the newly built experimental institutions, most of them are equipped with variable frequency power supplies, which can be tested according to the practical frequency of the motor, but for some old experimental equipment or some repair units, it is not necessary to have variable frequency experimental conditions, and how to experiment about 60Hz motors?

According to the theoretical speculation in this paper, when the power frequency 50Hz power supply is selected, the voltage drop method should be selected, and the voltage experiment should be applied according to the calculated value of the motor additional voltage divided by 1.2.

More on that
Schneider inverter fault repair Schneider inverter fault repair

Inverter communication failure · Fault code: SLF Fault title: Inverter communication problem. Cause of the failure: Communication abort on the inverter communication bus. The way to deal with the fault: check whether the communication connection is normal: check the communication timeout setting: check the ...

Deterioration site and the principle of higher harmonic generation - Schneider Deterioration site and the principle of higher harmonic generation - Schneider

1. Electrical equipment will produce higher harmonics when it produces abnormality and deterioration, and the abnormality and deterioration of motors, loads, and inverters are used to distinguish the higher harmonics from 2 to 40 times, and the data is changed by FFT, and the analysis is made on the basis of the analysis data of long-term savings.

The control mode of low-voltage inverter - Schneider The control mode of low-voltage inverter - Schneider

From the perspective of skills alone, the control method of the low-voltage inverter also indicates its skill portal to a certain extent. Here, we've broken down the following manipulation methods: 1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by the simple structure of the control circuit, the cost of ...

Schneider inverter debugging steps and brief description Schneider inverter debugging steps and brief description

Commissioning process of the Schneider 61 series 1. Preparations 1. Measure insulation. Connect the power supply side (R.S.T) and the motor side (U.V.W) of the inverter Disconnect the cable, insulate the cable with a 500 megaohm or 1000 megaohm shake meter, and if it meets the requirements, restore it.

Pay attention to the problem of false load connection method in inverter debugging - Schneider Pay attention to the problem of false load connection method in inverter debugging - Schneider

There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...

Analysis of common problems of Schneider inverter Analysis of common problems of Schneider inverter

1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA? Because the maximum output frequency parameter of the inverter is "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...

Schneider servo drive fault code Schneider servo drive fault code

1. AL001: overcurrent, the current value of the main 2113 circuit exceeds the motor instantaneous 5261*** high current value 1.5 times when the action is 4102. 2. AL002: overvoltage, the voltage value of the main return 1653 channel is higher than the standard value. 3. AL003: low voltage, the voltage value of the main circuit is lower than the standard.

How to choose a Schneider circuit breaker? How to choose a Schneider circuit breaker?

First, calculate the value of the current of each branch (1) Purely resistive loads, such as bulbs, electric heaters, etc., are directly divided by the indicated power by voltage, that is, the formula I = power/220v; For example, a 20w bulb, branch current I=20W/220=0.09A electric air ...

Schneider circuit breakers, contactors, thermal relays selection Schneider circuit breakers, contactors, thermal relays selection

In daily work, the combination of circuit breaker, contactor and thermal relay is the most common combination of motor power supply circuit, and the circuit breaker is generally the short-circuit instantaneous action of magnetic maintenance, the contactor realizes relay logic control, and the thermal relay overload maintenance. The parameter selection method of these three kinds of gas parts is as follows: ( ...

The 7 peripherals of the inverter governor - Schneider The 7 peripherals of the inverter governor - Schneider

1. Air circuit breaker is an active electrical appliance that can not only touch and disconnect the circuit normally, but also operate under abnormal conditions such as overcurrent, reverse current, short circuit and loss (under)voltage. Its primary role is to maintain the electrical equipment in the AC and DC circuits, and it can also operate the circuits infrequently. ...

Introduction to Schneider PLC series Introduction to Schneider PLC series

1. LMC058 & LMC078 Modicon Motion Controller Product Information Faster machine planning The motion controller uses the same programming software as the PLC; Custom-made utility blocks for complex use; Dedicated motion function library for programming, debugging, and diagnosis ...

Input/output pins P0, P1, P2, P3 functions Input/output pins P0, P1, P2, P3 functions

P0.0——P0. 7 : Port P0 is an 8-bit open-drain bidirectional I/O port. When visiting off-chip memory, it is time-shared for a low-8-bit address and an 8-bit bidirectional data bus. When EPROM is programmed, the instruction byte is input by P0, and when the program is verified, it outputs ...

Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker Circuit breaker mechanical characteristics tester operation steps - Schneider circuit breaker

Circuit breaker action time test. The closing and opening control lines of the circuit breaker mechanical characteristics tester are respectively connected to the secondary control line of the circuit breaker, and the lead wires of each break of the circuit breaker are connected to the mechanical characteristics of the circuit breaker with the test wiring.

Schneider inverter external potentiometer connection Schneider inverter external potentiometer connection

The two wires are connected to the resistor, and the other wire is connected to the conditioning terminal. The red thread is attached to the blackhead and inserted in a small hole. Connect both ends of the IR potentiometer to +10V and ACM, and slide the termination to the voltage input terminal AVI. ...

Inverter maintenance mantra method - Schneider Inverter maintenance mantra method - Schneider

Don't worry about the damage of the frequency conversion, disassemble the machine after the discharge; It is indispensable to ask for a diagnosis and clarify the problem at the beginning of the test; Input and output PN junction, three-phase balance and then unshelling; Look at the nameplate before powering on, the wrong voltage will blow up; The bus has no electricity to see that it is safe, and the rectifier filter is wrong ...

There is no indication on the UPS boot panel that UPS is not working - Schneider There is no indication on the UPS boot panel that UPS is not working - Schneider

Fault analysis: judging from the fault phenomenon, the fault is in the mains input, battery and mains detection part and battery voltage detection loop: 1. Check whether the mains input wire is incinerated; 2. If the mains input is stable...

Schneider miniature circuit breaker problem analysis and answer Schneider miniature circuit breaker problem analysis and answer

Fault 1: The shell of Schneider MCB product is yellowed or burned. Reason 1: It is very likely that the magnetic coil inside the circuit breaker is burned out because of harmonics or high-frequency signals. Method 1: * The good thing is that the filtering can be satisfied with the use of 50Hz/60Hz power frequency. ...

How to operate the transformer DC resistance tester – Schneider How to operate the transformer DC resistance tester – Schneider

1. The instrument test has a total of YN winding three-phase test, YN winding three-phase phase-by-phase test, low-voltage winding magnetization method test of iron-core five-column low-voltage angular transformer, low-voltage winding phase selection test and general four-terminal method of ironcore three-column low-voltage angular transformer. ...

Where the inverter filter is suitable - Schneider Where the inverter filter is suitable - Schneider

1. LC filter LC filter is suitable for occasions with low requirements for harmonic content, and a good LC filter can control the distortion rate at 8-10%; 2. Harmonic filter This filter is suitable for harmonic ...

Schneider Category VI unshielded RJ45 information module Schneider Category VI unshielded RJ45 information module

Product Introduction compose 1. RJ45 module body, 8 IDC contact pins 2. Crimping module 3. Back cover 7751S (optional) Operating temperature range -40°C to +70°C (65°C for non-stop use) ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top