Sensitive operation form, satisfactory business operation policy:
Four-level inverter technology: Galaxy VX uses innovative patented four-level inverter technology to reduce power consumption and pressure on power components, and complete the perfect unity of high power and component reliability.
Sensitive operation form: Galaxy VX supply e change form is a combination of energy-saving form and double change form, three operation forms can be switched freely, each form is · All have different power and performance, even at very low load factors, high power can be achieved and cost saving;
Scalable planning, satisfying the way transactions work:
The Galaxy VX uses a 250kW power cabinet, which can be used to increase the load capacity or redundancy after the initial installation is completed. Reinventing the UPS system's approach to satisfying the operation of transactions, and its agility to pay as it grows provides an aspirational channel for the expansion and rebuilding of critical use. Thanks to the innovative skills of Galaxy VX, customers can choose the most suitable UPS according to the transaction policy, and ensure the increasing transaction demand on demand.
Diversified energy storage is compatible with future energy demand changes:
Galaxy VX is compatible with a variety of forward-looking energy storage skills, including lead-acid batteries, lithium batteries, nickel-cadmium batteries, and flywheel energy storage, providing customers with an easy solution to meet future energy demand changes in supply.
|
More on that
|
Schneider Electric has announced the launch of its Pacific Foundation
Schneider Electric has announced the launch of its Pacific Foundation, which will provide financial and advisory support to charitable foundations in the Pacific region to address fundamental human rights issues of access to energy. Four foundations were selected as the Foundation's initial recipients.
|
|
Inverter maintenance inspection steps – Schneider
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is in normal operation, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in operation conditions, and do the corresponding recording operations; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...
|
|
Electrical Control Line Fault Analysis Method - Schneider
1) Survey and research method. The investigation and research method is to "see", "listen", "smell", "touch" and "ask" to understand the significant faulty phenomena; After visiting the operator, understand the cause of the problem; A common way to help find faults after consulting others or consulting information ...
|
|
Schneider circuit breaker maintenance method
1. Insist that the air is moist or unclean, and the pipes are not clean, which may have the following consequences:
(1) The wet gas is decomposed into mixed gases such as hydrogen and oxygen under the effect of arcing, destroying the insulation between the fractures after the main contact is broken, which is difficult to arc or arc re-ignition, and in severe cases, arc extinguishing will be formed.
|
|
Inverter power settings, waveform test issues
1. After the inverter is repaired, the power number demand is corrected, don't forget
Generally, an inverter corresponds to a power number (also known as the number of horsepower), for example, a 75 kilowatt inverter is set under heavy load, and 100 kilowatts is set under light load. In this way, the customer will not use it to present ...
|
|
Schneider inverter Eplan file download
Product line:
Frequency converters and soft starters
Solution(s):
All Eplan software users can visit the Eplan website (directly from the Eplan software). The EPLAN database includes ...
|
|
Fault check steps for frequency converters - Schneider frequency converters
1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is running normally, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in the operating state, and do the corresponding recording work; When repairing the inverter, check whether the voltage value and current value exceed the allowable ...
|
|
Pay attention to the problem when using UPS power supply - Schneider
1. The parameters set in the host cannot be changed at will during use. In particular, the parameters of the battery pack will directly affect the service life. With the change of ambient temperature, the float charge voltage should be adjusted accordingly. Generally, 25 °C is the standard, and when the ambient temperature rises or falls by 1 °C, the float charge ...
|
|
The difference between an inverter and a servo drive – Schneider
In terms of frequency converters:
The abbreviated inverter can only regulate the speed of the communication motor, and the open-loop or closed-loop can be determined depending on the control method and the inverter, which is the traditional V/F control method. Now many of the frequency conversion has been set up by mathematical models, which will communicate electricity ...
|
|
Schneider instrumentation accuracy
It refers to the degree to which the average value measured repeatedly under certain test conditions is consistent with the true value, which is indicated by error. It is used to indicate the magnitude of the error in the system. In practice, control tests are generally carried out with standardized substances or normative methods, and when there are no standardized substances or normative methods, it is often used to add ...
|
|
Schneider circuit breakers, contactors, thermal relays selection
In daily work, the combination of circuit breaker, contactor and thermal relay is the most common combination of motor power supply circuit, and the circuit breaker is generally the short-circuit instantaneous action of magnetic maintenance, the contactor realizes relay logic control, and the thermal relay overload maintenance. The parameter selection method of these three kinds of gas parts is as follows: ( ...
|
|
Calculation method of inverter capacity - Schneider
1. Accounting of inverter capacity when the load is continuously changed periodically
In many cases, the load of the motor changes periodically. Obviously, in this case, picking the capacity of the inverter according to the minimum load will be overloaded, and it will be uneconomical to select according to the maximum load.
|
|
There is a remote code execution vulnerability in Schneider industrial equipment
Recently, Armis security researchers have reported that Schneider Electric's programmable logic manipulators (PLCs) have serious and unpatched gaps in long-distance code fulfillment, allowing intruders to manipulate their various industrial systems.
Schneider ...
|
|
The inverter controls the speed of the AC motor – Schneider
Most of the motors used in the industry are of this type. The rotational speed of an induction AC motor (henceforth referred to as a motor) is approximately determined by the number of poles and frequency of the motor. The number of poles of the motor is fixed by the working principle of the motor. Since the pole ...
|
|
Schneider Modicon M100 Programmable Controller Features and Benefits
The Schneider Electric Modicon M100 programmable controller is part of the Easy Series and is suitable for simple I/O logic control machines.
characteristic
AC power supply
High-speed processor with 0.2μs/boolean amount
Built-in a ...
|
|
Analysis of common problems of Schneider inverter
1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA?
Because the maximum output frequency parameter of the inverter is "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...
|
|
Schneider UPS power supply common fault analysis
1. When there is mains power, the UPS output is normal, and when there is no mains power, the buzzer beeps for a long time and there is no output
Fault analysis: From the phenomenon to identify some problems of the battery and inverter, you can view it according to the following procedures:
1. Check the battery voltage to see if the battery is undercharged.
|
|
Precautions for false load connection in Schneider inverter debugging
There are many novices who are not familiar with the fake load when repairing the inverter, and the repair of the inverter saves many of their modules with the false load, because the novice repairer generally does not know how to do this, and now the light is on to make it clear that the module is going to be broken. A false load is a resistor with a few hundred ohms ( ...
|
|
Maintenance and overhaul of frequency converters and soft starters
The protection and viewing of inverters and soft starters is a useful means to prevent occasional equipment problems. In order to be useful for protection and inspection, inspection orders should be created to record and save the inherent characteristics of the equipment and the stability of the constituent parts, so as to prevent problems and problems that occur.
|
|
Schneider inverter knowledge points
1. Use the analog output port to indicate the motor frequency, when the motor frequency is 50Hz, why is the output only 16mA?
Due to the maximum output frequency parameter of the inverter "TFR", the factory default value is 60Hz. So when the inverter output is 50Hz, the analog output is 16mA. At this time, only ...
|
|