Schneider PLC series features

Create Date: 2024-8-30 12:03:23|Source: Schneider/Schneider

Schneider TSX08 series NEZA PLC

It is a small PLC with abundant functions, small size, strong general-purpose type, and high cost performance.

NEZA series adopts a new generation of handheld programmer, and the operating system adopts PL707-WinCE to support Chinese interface. In the process of use, whether it is programming, monitoring, debugging or on-site operation, it is very fast. In addition, it is worth mentioning the customization of utility blocks, which allow you to put your algorithm directly into the utility block, and the system is able to run it as a standard instruction. I/O points can be scaled from 20 to 80.

Schneider TSX 57 Series Premium PLC

Medium-sized rack with strong CPU power, fast speed, and large memory.

Abundant networking and communication functions. Compact and sensitive switching and a wide range of analogue modules.

Special modules: high-speed counting module, axis control module, stepping control module, communication module and weighing module.

The programming environment is the same as that of a Micro PLC.

                                 Schneider PLC series features

Schneider 140 Series Quantum PLC

Easy configuration and simple protection.

Sensitive selection of structures and modules.

With tens of thousands of installed bases worldwide, it has been proven to meet the needs of various applications in countless applications.

Powerful processors, advanced IEC method programming, support a variety of networks.

Schneider TSX37 Series Micro PLC

Compact rack, small size, strong function, sensitive configuration, low price. Suitable for the characteristics of the Chinese market

Powerful CPU power. Fast speed, large memory, integrated LED display, and multitasking.

Compact I/O module design with high switching I/O capacity (up to 248 points). The analog I/O has a large number of points (up to 41 points) and strong function (there is a 40KHz high-speed counting module and an integrated 10KHz hardware counting and 500Hz software counting, etc.).

More on that
Inverter selection and capacity matching - Schneider Inverter selection and capacity matching - Schneider

In addition, it is unscientific to select the inverter body alone, without considering whether the inverter selection and capacity matching are appropriate. ...

Schneider inverter frequency signal source mode Schneider inverter frequency signal source mode

In order for the inverter to operate normally, it must have two basic conditions, that is, the frequency signal and the operating signal, let's talk about the first condition, which is the frequency signal of the inverter. Our intention to use the inverter is to change the ...

Precautions for external wiring of the inverter Precautions for external wiring of the inverter

In the process of connecting the line of the inverter, it is necessary to pay attention to the following aspects: 1. The power supply must be connected to the main circuit power terminal L1/R, L2/S, L3/T, if the power supply is connected to other terminals by mistake, the inverter will be damaged. 2. It is necessary for the grounding terminal to be well connected.

Schneider TRSS telemetry system solution Schneider TRSS telemetry system solution

Schneider Electric provides safe, reliable, end-to-end telemetry solutions to help you meet the challenges of long-distance operations. With an outstanding reputation in the fields of appearance, manipulation and data collection, wireless communications, IT, and other industries and common sense, Schneider Electric telemetry system solutions can help ...

Schneider inverter inverter field interference solution Schneider inverter inverter field interference solution

1. Use software anti-disturbance method In detail, the carrier frequency of the inverter is lowered through the human-machine interface of the inverter to an appropriate scale. If this method does not work, then the following hardware anti-disturbance method can only be adopted. 2. Carry out positive ...

Precautions for setting parameters of Schneider inverter Precautions for setting parameters of Schneider inverter

 Debugging parameters: ​ 1. Acceleration and deceleration time Speed up the time setting requirements: the acceleration current is constrained below the overcurrent capacity of the inverter, so that the overflow will not cause the inverter to trip; Deceleration time setting key ...

How to operate the transformer DC resistance tester – Schneider How to operate the transformer DC resistance tester – Schneider

1. The instrument test has a total of YN winding three-phase test, YN winding three-phase phase-by-phase test, low-voltage winding magnetization method test of iron-core five-column low-voltage angular transformer, low-voltage winding phase selection test and general four-terminal method of ironcore three-column low-voltage angular transformer. ...

Schneider Lexium ILA all-in-one AC servo Schneider Lexium ILA all-in-one AC servo

The Schneider Lexium integrated drive consists of an electric motor and a control circuit that announces the control signal via a fieldbus, pulse/direction interface or I/O interface (for internal motion tasks). High compactness: motor and control circuits ...

The difference between the highest frequency and the basic frequency of the inverter - Schneider The difference between the highest frequency and the basic frequency of the inverter - Schneider

1. There are two ways to say the fundamental frequency: (1) The frequency corresponding to the maximum output voltage of the inverter is called the fundamental frequency; (2) When the output voltage of the inverter is equal to the additional voltage, the minimum output frequency is called the fundamental frequency. The fundamental frequency is expressed in fBA. ...

Schneider Electric Innovation Summit "The future is digital" Schneider Electric Innovation Summit "The future is digital"

The name of a company's product was mentioned more than anyone could remember, but on the first day of the Schneider Electric North America Innovation Summit in Atlanta on Tuesday, another word appeared even more often ...

Schneider PLC intelligent parameter features Schneider PLC intelligent parameter features

Characteristic: 1. NEZA PLC (TSX08 series) EZA series is a small PLC with rich functions, high performance-to-price ratio, small size and strong versatility. A new generation of handheld programmer - Chinese PDA PL707WinCE, supports Chinese interface, whether it is programming, ...

Schneider disconnector operation inspection content and requirements Schneider disconnector operation inspection content and requirements

(1) Whether the closing of the barrier switch is defective, whether there is no failure or dislocation; (2) The porcelain insulation of the barrier switch should be free of cracks, discharge phenomena and flashover traces; (3), contact viewing: a, view ...

Schneider inverter maintenance inspection steps Schneider inverter maintenance inspection steps

1. Check whether the appearance of the inverter is in good condition, including whether the indicator light is in normal operation, whether the task control function of the operation panel is complete, and carefully observe the appearance of the inverter in operation, and do the corresponding recording operation; When repairing the inverter, check whether the voltage value and current value exceed the promised ...

There is no indication on the UPS boot panel that UPS is not working - Schneider There is no indication on the UPS boot panel that UPS is not working - Schneider

Fault analysis: judging from the fault phenomenon, the fault is in the mains input, battery and mains detection part and battery voltage detection loop: 1. Check whether the mains input wire is incinerated; 2. If the mains input is stable...

A brief description of the working principle of Schneider power soft starter A brief description of the working principle of Schneider power soft starter

Schneider ATS48 soft starter is composed of three opposite parallel thyristors, which are connected in series between the three-phase power supply and the motor, by changing the trigger angle of the thyristor gate pulse, the conduction angle of the thyristor gradually increases from zero, according to the pre-set soft starter parameter curve, the motor output torque ...

Key points of operation of Schneider disconnectors Key points of operation of Schneider disconnectors

Features of Schneider Barrier Switch: First of all, Schneider Barrier Switch can be used to block the power supply, it can disconnect the live equipment from the high-voltage maintenance equipment, and can also see the obvious disconnection point on it. Secondly, Schneider barrier switches can cooperate with circuit breakers to change the operation of the system.

Turbine flowmeter selection factor - Schneider Turbine flowmeter selection factor - Schneider

Turbine flowmeter is a kind of speed appearance, it has high precision, good repeatability, no zero drift, high range ratio, simple structure, few moving parts, high pressure resistance, wide measurement scale, small size, light weight, small pressure loss, convenient repair and other advantages, turbine flowmeter has high quality ...

AC-DC inverter composition and function - Schneider AC-DC inverter composition and function - Schneider

The AC-DC inverter main circuit consists of three components: the rectifier main circuit, the center circuit and the inverter circuit. 1. The main circuit is the power replacement part that provides voltage regulation and frequency regulation power supply for the asynchronous motor, and the main circuit of the inverter can be roughly divided into two categories: the voltage type is the voltage source ...

Where the inverter filter is suitable - Schneider Where the inverter filter is suitable - Schneider

1. LC filter LC filter is suitable for occasions with low requirements for harmonic content, and a good LC filter can control the distortion rate at 8-10%; 2. Harmonic filter This filter is suitable for harmonic ...

The control mode of low-voltage inverter - Schneider The control mode of low-voltage inverter - Schneider

From the perspective of skills alone, the control method of the low-voltage inverter also indicates its skill portal to a certain extent. Here, we've broken down the following manipulation methods: 1. Sinusoidal pulse width modulation Sinusoidal Pulse Width Modulation (SPWM) is characterized by the simple structure of the control circuit, the cost of ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top