Advantages of busbar mounted electrical equipment - Wiener

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The novelty, flexibility and originality of the busbar device appliance. It indicates the vitality of this skill and its broad market prospects. This is the real reason why we pay attention to it.

                               Advantages of busbar mounted electrical equipment - Wiener

First of all, this kind of small electrical equipment is a novel concept, using the "non-hole lap technology" (the author's right to call it so), and the electrical equipment is directly installed on the busbar to form a power distribution or control loop. The representative creations are busbar device fuses and fuse load blocking switches.

Secondly, WOHNER Electrical Systems has developed a multi-standard modular bus system, and its bus system is diversified in modulus and standard, and the additional value is serialized. The modulus of the bus system is 40mm, 60ram, 100/185mm; The bus cross-section forms are rectangular, double "T" (i.e., "H" shape) and three "T" shapes (i.e., "state" shapes); The standard of the bus bar can be three-wire, four-wire or five-wire, or even seven-wire, of course, it should be determined according to the need. Additional voltage of the bus system: 690V; Additional currents are: 630A/800A (rectangular), 1600A (double "T") and 2500A (triple "T"). The short-time withstand current of the bus system reaches 50kA (1s), and the peak withstand current reaches 117kA (three-wire)/120kA (four-wire).

WOHNER Electrical Systems has also developed a series of busbar adapters and a variety of busbar terminal blocks using the "Holeless Lap Technique" – universal busbar adapters, wire nose bolt couplings and three-phase combination terminal blocks.

The busbar adapter clamp is suitable for both rectangular busbars and double "T" type or triple "T" type busbars; There are direct hard connections and soft connections; There are straight splint types with hard joints, and there are 90 types. Angular lap type; There are straight and 900 corner joints: the cross-section of the wire can be connected to the rectangular copper and aluminum bar, and the circular or even fan-section cable can be connected. Wire nose bolt adapter clamps are suitable for connecting cables with "O" or "U" type crimp terminals. The three-phase combined terminal block can be connected with a protective cover, or without a protective stripe, it can be connected to a rectangular copper and aluminum bar, or it can be connected to a cable or a soft flat copper foil busbar. The additional current of the busbar adapter clamp varies from 630 to 2500A; The additional current of the general-purpose busbar adapter clamp is 1 80-800A; The additional current of the wire nose bolt coupling clamp is 63-250 # 4 The additional voltage of the three-phase combined terminal board is 690V, and the additional current is 63-1250A.

Thirdly, another creation of WOHNER Electric's "non-porous articulation skills" is the busbar adapter. The bus adapter is a transition part of the electrical equipment directly installed on the bus system. It can be used to install air circuit breakers, contactors and control appliances and other components of major companies in the world such as Germany Siemens, AEG, Klckner-Moeller, United States GE, France Schneider, Switzerland ABB, Japan Mitsubishi and other major companies in the world on the busbar. There are several types of bus adapters: the Eques Easycontroller and the Eques Easyconnectorer with integral insulated panels. The additional voltage is 690V; There are four standards for each type by additional ammeter: 25, 32, 63 and 80A. They can be carried without a standard rail or with 1 or 2 standard rails. There is also a universal bus adapter with an additional voltage of 690V; There are 160, 200 and 630A_ standards for additional currents. The universal busbar adapter is suitable for the direct installation of electrical components of larger standards.

Eventually, w6HNER Electrical Systems has developed a series of other products, such as a series of universal fuses for electrical cabinets, fuse blocking switches, generalized and serialized insulating components and protective parts.

More on that
The advantage of busway over cable in construction - Wienal The advantage of busway over cable in construction - Wienal

Modern power supply lines play a very important role like the aorta of the human body, and if something goes wrong, it can have serious consequences. Before the 80s of the 20th century, many stable cables were used in modern construction. With the rapid development of the city, the power load of the building ...

Difference Between Busbar and Cable in Power System – Wiener Difference Between Busbar and Cable in Power System – Wiener

Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is delivered to individual users.

Laminated busbar system – Wiener Laminated busbar system – Wiener

In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar. ...

Bus voltage non-system equipment fault handling method - Wiener Bus voltage non-system equipment fault handling method - Wiener

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require voltage separation to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, in the actual operation of the power grid, due to the change of active and reactive power output, the increase or decrease of the electrical load, the system wiring party...

Dense busbar installation – Wiener Dense busbar installation – Wiener

1. Requirements for civil engineering before installation 1) The foundation, structure, reserved holes and embedded parts all meet the design requirements of electrical equipment. 2) After the construction of the roof and floor slab is completed, there shall be no leakage. 3) After the indoor ground construction is completed, mark the ground leveling line on the well wall. ...

Characteristics of single bus wiring in the switchgear - Wiener Characteristics of single bus wiring in the switchgear - Wiener

In power distribution equipment such as voltage distribution cabinets and switchgear at all levels of power plants and substations, the conductors connected between large electrical equipment such as generators and transformers and various electrical equipment are called busbars. Busbars, also known as busbars, are used to gather, distribute, and transmit electrical energy. The connection methods of the bus bar are ...

Temperature rise requirements and safety of Wiener busway Temperature rise requirements and safety of Wiener busway

With the rapid development of our economy and technology, the trend of urbanization is becoming more and more popular, and people's electricity consumption is also increasing. In this case, the busway has developed significantly, and the use of instead of cable has become the development trend of the times. Therefore, what are the requirements for the temperature rise of the busway and ...

Comparison of several insulated tubular busbars Comparison of several insulated tubular busbars

The use of insulated tube bus in China has a history of nearly 20 years, and it has made a historic contribution to reducing the layout space of the distribution bus and improving the reliability of the bus operation. There are many manufacturers who supply this product, and their production processes are uneven, and the differences in processes are mainly reflected in the ...

What are the common types of fuses - Wiener What are the common types of fuses - Wiener

Plug-in fuse: It is commonly used at the end of the line at the voltage level of 380V and below, as a short-circuit maintenance for distribution branch lines or electrical equipment. Spiral fuse: The upper end of the melt is covered with a fuse indicator, once the melt is melted...

The difference between metal busbar and closed busbar - EVOC The difference between metal busbar and closed busbar - EVOC

The nature is different Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches. Busway: It is a closed metal equipment composed of copper and aluminum busbars. Different uses Mother...

Busway installation method - Wiener Busway installation method - Wiener

1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm; 2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts. 3. In the process of installation construction, priority should be given to the power supply system, ...

The difference between air-type busway and dense busway - Vernal The difference between air-type busway and dense busway - Vernal

1. The insulating medium is different: there is a certain open space between the copper bars of the air bus duct, that is to say, the insulation between the copper bars mainly depends on air, and the insulation medium between the copper bars of the dense bus duct (many people call it a closed bus duct) is an organic insulating material. 2. Copper bar placement ...

Analysis of the product characteristics of Wiener busway Analysis of the product characteristics of Wiener busway

Since the busway is made of copper bars or aluminum as conductors, it has a large current capacity and good electrical and mechanical properties. In addition, it is made of a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution or ...

What are the characteristics of the bus wiring method of the power system? What are the characteristics of the bus wiring method of the power system?

(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected. ...

220V DC Hazard of Bus System – Wiener 220V DC Hazard of Bus System – Wiener

The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of the DC are insulated from the ground, and when the ground of one pole is generated, there is no grounding current due to the fact that there is no grounding current.

Difference Between Busbar and Busway – Vernal Difference Between Busbar and Busway – Vernal

The connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, mostly use bare wires or stranded wires of rectangular or circular cross-section, which are collectively referred to as busbars. The role of the bus bar is to collect, distribute and transmit electrical energy. Because the busbar ...

Standard parameters of busway specification - Wiener Standard parameters of busway specification - Wiener

1. The standard scale of the bus duct This specification regulates the terminology, skill requirements and test methods of the insulated bus trunk system (bus duct) and its plug-in feed box (hereinafter referred to as the feed box). This specification specification applies to additional voltage AC to 660V...

The common DC bus of the inverter system - Wiener The common DC bus of the inverter system - Wiener

1. Three-phase AC power supply inlet The power input of each inverter is connected in parallel on the same AC bus, and the power supply phase of the input of each inverter is consistent. In Figure 3, the circuit breaker QF is the incoming protection device for each inverter. LR is an incoming reactor, when multiple inverters are in the same ...

Low-voltage dense busway uses and applications Low-voltage dense busway uses and applications

Densely insulated bus duct (hereinafter referred to as bus duct) can be communication three-phase three-wire, three-phase four-wire, three-phase five-wire system, frequency 50-60Hz, voltage to 400V, rated operating current of 250-5000A, mainly as a new type of power supply and distribution equipment in industrial and mining, enterprises and high-rise buildings. Mother with insertion day ...

Busbar system segmentation understanding - Wiener Busbar system segmentation understanding - Wiener

The so-called "section" of the bus bar is that the data that constitutes the bus are directly connected, and there is no circuit breaker or blocking switch in the center. A circuit breaker or barrier switch in the center is called a "segment". Different voltage levels cannot be connected in the same section. No...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top