Densely insulated bus duct (hereinafter referred to as bus duct) can be communication three-phase three-wire, three-phase four-wire, three-phase five-wire system, frequency 50-60Hz, voltage to 400V, rated operating current of 250-5000A, mainly as a new type of power supply and distribution equipment in industrial and mining, enterprises and high-rise buildings. The busway with plug-in day can easily lead out the power supply shunt through the plug-in connector box or pull-out switch box. The busway has the advantages of small size, compact structure, large transmission current, and convenient protection. The device of the bus duct can be connected from the transformer to the low-voltage distribution cabinet, and can also be directly connected to the distribution system from the low-voltage cabinet as the distribution trunk line.
. Scope of application
The busway operates normally for a long time in the following environments:
a. The altitude does not exceed 2000m;
b. The nearby air temperature is between -5 and +40 °C, and its uniform leakage is not higher than +35 C within 24 hours;
C. Clean air, the relative humidity does not exceed 50% at a high of +40°C, and a higher relative humidity is allowed at a lower temperature; For example, 90% at +20°C, but it should be taken into account that due to temperature changes, there is a possibility that moderate condensation may occur inadvertently and accidentally.
d. The pollution level is level 2:
e. The device type is class III and IV;
f. The device method is delineated according to the use of imitation sheets.
2.2 Busway TH type products in 2.1 a.b.e.f listed in the article f'f and the following articles under the normal T operation;
a. The relative humidity of the air is not more than 95%;
b. Local areas with condensation and mold
|
More on that
|
The connection method of the tubular busbar
In the industry, tubular bus bar can be described as one of the more common equipment, with high mechanical strength, good insulation, wide range of application and other characteristics of many enterprises. So do you know what are the ways to link tubular busbars?
...
|
|
Strip Switch vs. Disconnector Circuit Breaker Comparison – Wiener
Bar switches are different from regular switches. They are critical to ensuring effectiveness. For example, when the current exceeds a certain amount of time, they cause heat to be generated, allowing the fuse to switch the fuse to further assist in breaking the circuit. Therefore, as a kind of current protection device, they can achieve ...
|
|
A detailed description of the Wiener comb busbar and connection terminals
The Wiener comb busbars and connection terminals are available with QUADRON®CrossLinkBreaker in size 000/00
Recommended installation: Wire entry at the lower end of the NH-fuse disconnector through the comb busbar.
In the mounting position ...
|
|
The main components of the Wiener bus system in the distribution cabinet are composed
The Wiener bus system is divided into 40mm, 60mm, 100mm and 185mm systems according to the upper and lower spacing between the copper bars, and the ship unloader distribution cabinet mainly adopts a 60mm rectangular bus system. This is shown in the figure below. The 60mm system provides maximum operating space and maximum current with its smallest external size.
|
|
Introduction to Laminated Busbar System – Wiener
In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar.
...
|
|
Lighting power busway service life - Wienal
The system consists of a current box, a bus body, a branch plug and device accessories.
When the heat dissipation of conductive copper strip has been effectively improved, the contact between the copper strip and the inner wall of the tube is reduced, and the insulation resistance and anti-aging ability of the tube body are strengthened, so as to prolong the service life of the pipe body. The life of the tube far exceeds ...
|
|
Introduction to the Wiener busbar system
The 60mm bus system refers to the three- or four-wire bus spacing of 60mm.
In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the optimal distribution of current intensity levels, ...
|
|
Features of the use of closed busway - Wiener
Compared with other air-type busway, Wiener closed busway has many similarities in appearance, and its difference lies mainly in the shell, the structure of the closed busway is more distinctive, which also makes its use have certain advantages. As long as it is in contrast ...
|
|
The essence of Wiener busbar technology
1. Closed busbar hooking technology
Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.
|
|
What is the difference between a Wiener busbar and a cable
The difference between busbar and cable
The busbar is used to gather current. Many power and power supply circuits are connected to the bus, through which the power is gathered and sent to each circuit. Therefore, the current carrying capacity of the bus bar is relatively large, and the current carrying capacity of the bus ...
|
|
Features of Wiener busway
The Wiener busway mainly acts on the aluminum conductor, which has a large current capacity and good electrical and mechanical properties. In addition, it uses a metal trough as the shell, so it is non-flammable, safe and reliable, and has a long service life. Compared with traditional power distribution, the equipment occupies a significantly smaller area and has a beautiful appearance.
...
|
|
Uses and characteristics of detached closed busbar - Wiener
Closing busbars include out-of-phase shut-off buss, co-box (including co-box phase isolation) shut-off busbars and cable busbars, which are used for power plants, substations, industrial and civil power supply leads.
Phase-off busbar
1. Usefulness
Out of phase ...
|
|
Mesh tray reduces the cost of replacing cables – Wiener
(1) Simple maintenance and repair operations
Equipment is often added or removed or changed in the computer room, and cables are removed or added at the same time, and the grid bridge with open structure can observe the cables to the maximum extent, so it is easy to distinguish the cables that need to be replaced, so that maintenance and repair ...
|
|
220V DC Hazard of Bus System – Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of the DC are insulated from the ground, and when the ground of one pole is generated, there is no grounding current due to the fact that there is no grounding current.
|
|
Spring bracket installation steps in busbar system – Vernal
The function of the tension spring bracket in the bus system is to fix the orientation and stability of the bus duct, and it must be very careful during construction, otherwise the bus duct will fall, which will cause a very serious accident.
The device step of the tension spring support in the bus system ...
|
|
Advantages of pluggable busway
1. The plug-in bus duct has strong overload capacity
The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105 is selected for the insulation data used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed.
|
|
Precautions for terminal block wiring - Wiener
1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation.
2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...
|
|
Performance characteristics of low-voltage busbar system - Wienal
Introduction to the performance of low-voltage bus system:
1. The bus bar is not perforated, and is connected with the cable and copper bar through the connection clip or terminal
2. Switches, contactors and other electrical components can be directly hung on the bus through adapters
3. Save ...
|
|
Dense busbar installation – Wiener
1. Requirements for civil engineering before installation
1) The foundation, structure, reserved holes and embedded parts all meet the design requirements of electrical equipment.
2) After the construction of the roof and floor slab is completed, there shall be no leakage.
3) After the indoor ground construction is completed, mark the ground leveling line on the well wall.
...
|
|
The Hazards of Arc Light – Wiener Busbar System
The arc of the switchgear cable spacing causes the pressure and temperature in the switchgear to increase rapidly, and if not removed in time, it will cause serious harm in the following aspects:
(1) The arc temperature is 2 times the appropriate solar temperature, and the large ...
|
|