Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is transmitted to individual users or other substations.
In the power system, the bus connects the various current-carrying branch circuits in the distribution unit and plays the role of accumulating, distributing and transmitting electrical energy.
According to the appearance and structure, the bus bar is roughly divided into the following three categories:
1. Hard busbar: including rectangular busbar, round busbar, tubular busbar, etc.
2. Soft busbar: including aluminum stranded wire, copper stranded wire, steel-core aluminum stranded wire, expanded hollow wire, etc.
3. Close busbar: including common box bus, split-phase bus, etc.
Performance:
The bus bar is made of copper or aluminum, which has high current density, small resistance, and small skin effect, so there is no need to reduce the capacity of the busbar. A small voltage drop also means less energy loss, which ultimately saves the user's capital. As for the cable, because the cable core is a multi-strand thin copper wire, its root area is larger than that of the bus bar of the same current level. Moreover, its "skin effect" is severe, reducing the current rating, increasing the voltage drop, and simply generating heat. The energy loss of the line is large, and it is simply aged.
The bus refers to the connection of voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices. The effect of the busbar is to gather, distribute and transmit electrical energy.
Difference Between Busbar and Cable:
The busbar is used to gather current. Many power and power supply circuits are connected to the bus, through which the power is gathered and sent to each circuit. Therefore, the current carrying capacity of the bus bar is relatively large, and the cross-section of the bus bar is large, so the bus bar is generally selected as a bare bus type;
Cables are used to transmit cables, and some of them use the type of cable to transmit power from the power supply to the load at a long interval. The current carrying capacity of the cable is relatively small, and the insulation method is selected, which can be laid underground, trenches and overhead structures.
From the perspective of current carrying capacity, wires and cables carry small currents, and bus bars carry large currents;
From the perspective of structural form, the wire and cable are flexible (the internal copper core and the outer insulation layer) can be bent, and the bus bar is rigid (the internal hard copper bar and the external steel or aluminum alloy shell) can not be bent, and the bend is specially manufactured;
From the point of view of the use characteristics, the wire and cable device is troublesome, each electrical equipment needs to be independently pay-off and wiring, and the bus bar is convenient and sensitive, not simple device error, a bus can be used for many points of equipment together.
|
More on that
|
The advantage of closed busbar over open busbar is Wiener
1) Closing the bus duct can reduce the grounding fault, prevent the short circuit between the phases, and fundamentally eliminate the grounding fault caused by external moisture, dust and foreign objects, and improve the continuity of generator operation.
2) Eliminate the surrounding ...
|
|
How to solve the fault of the busway
If there is a problem in the bus duct of the double bus wiring, it is necessary to pay attention to the operation mode of bus maintenance in the process of dealing with the problem, and if necessary, the bus maintenance should be stopped for a short time. After the bus voltage disappears, the dispatcher should immediately swing the switch (including the bus tie switch) that may call, and notify the operation team to ...
|
|
The role of plug-in busway – Wiener
Generally speaking, plug-in busway is mainly used for power transmission. We know that all conductors will have losses, and the losses caused by the flow of electricity through conductors are larger and some are smaller. For example, compared with the aluminum wire with the same wire diameter and the copper wire, the loss of aluminum is larger, and the loss of copper is smaller. That is, the conductivity ...
|
|
Several faults of the Wiener bus system can be avoided
Cause of bus failure
1. The inner network of the bus insulator and the breaker sleeve caused by the dirty appearance
2. The voltage transformer installed on the bus and the current transformer between the bus and the circuit breaker fail
3. Reverse gate ...
|
|
Precautions for the installation of explosion-proof distribution boxes - Vernal
The protection level mark of explosion-proof distribution box is the protection level of IP products that we often mention, which has two parameters, one represents the level of avoiding foreign objects from entering the shell, and the second represents the level of waterproof entering the shell.
Installation of explosion-proof ...
|
|
The importance of busbar systems in low-voltage switchgear
One of the characteristics of low-voltage switchgear is the multi-functional busbar system.
The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical equipment. The role of the bus is to, sub-...
|
|
Aluminum alloy busway circuit continuity - Wiener
The continuity of the aluminum alloy bus duct maintenance circuit is related to the PE line, and the crossover PE wire conductor bus of the maintenance conductor and the two-unit bus bar should reach 50% of the phase line, the equivalent cross-sectional area. The continuity resistance of the housing and PE line maintenance circuit is ≤ 0.005 ohm female, and the unit with jumper wire is not less than the maintenance conductor.
|
|
Busbar system segmentation understanding - Wiener
The so-called "section" of the bus bar is that the data that constitutes the bus are directly connected, and there is no circuit breaker or blocking switch in the center. A circuit breaker or barrier switch in the center is called a "segment".
Different voltage levels cannot be connected in the same section. No...
|
|
Uses and technologies of cable junction boxes – Wienal
XBT series mine flameproof communication cable distribution box has the characteristics of small size, reasonable cable import and export, and wide coverage. Each distribution box has 4-10 inlet and outlet bells, which is suitable for HUYV type mine signal cable in coal containing sexual gas (methane) mixture (non-mining face).
|
|
Introduction to the Wiener data center bus system
Although the service life cost of the bus system is usually lower than that of the traditional wiring method, the bus system still bears a considerable cost compared with other structural elements of the water supply and drainage or HVAC system.
In addition, customized busbar equipment allows the busbar system to be routed around obstacles ...
|
|
Detailed explanation of Wiener DC bus
1. Three-phase AC power supply inlet
The power input of each inverter is connected in parallel on the same AC bus, and the power phase of the input end of each inverter is ensured. The circuit breaker QF is the incoming line protection device for each inverter. LR is an incoming reactor, when multiple inverters are operating in the same environment.
|
|
The difference between the busbar system and the traditional wiring
The advantages of the busbar system are:
1. The Wiener bus system adopts the bus bar non-perforation connection technology, and the electrical components are firmly connected to the busbar;
2. It saves the device space, saves the redundant wiring, saves the device time and labor;
3. The busbar ...
|
|
Bus voltage non-system equipment failure and solution - Wienal
In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...
|
|
Fast protection of medium and low voltage busbars – Wienal
1.It is necessary to install arc light maintenance
Arc maintenance in foreign countries has nearly 20 years of history, the first set of maintenance devices in 1995 has been put into operation, China's previous imported units in the introduction of foreign complete sets of arc light maintenance (such as Guohua Tianjin Panshan Power Plant), domestic units ...
|
|
Advantages of pluggable busway
1. The plug-in bus duct has strong overload capacity
The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105 is selected for the insulation data used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed.
|
|
Wiener bearing repair technology
1. Comprehensive correction of bearings
The comprehensive correction of the bearing includes the comprehensive and strict correction process of the damaged bearing after cleaning, dismantling, inspection, roller table grinding or replacement of inner and outer rings, new rolling element manufacturing/original rolling element grinding, rolling element replacement, assembly, clearance adjustment and inspection and packaging.
|
|
The essence of Wiener busbar technology
1. Closed busbar hooking technology
Circuit breakers and contactors can be hooked on the bus through the bus adapter, and fuse switches and other products are directly attached to the bus, so the bus bar plays a two-layer effect of conductive and fixed rotation.
|
|
How to choose the right fuse - Wiener
1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses.
...
|
|
Temperature rise requirements and safety of Wiener busway
With the rapid development of our economy and technology, the trend of urbanization is becoming more and more popular, and people's electricity consumption is also increasing. In this case, the busway has developed significantly, and the use of instead of cable has become the development trend of the times. Therefore, what are the requirements for the temperature rise of the busway and ...
|
|
Composition of medium and low voltage bus protection - Wiener
On the medium and low voltage side of the main transformer, the bus tie switch and the original electromagnetic relay maintenance DC circuit of each outlet, the PLC is used for logical comparison to determine whether it is a fault in the maintenance area or a fault outside the area.
...
|
|