In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar.
Laminated busbar, laminated busbar or laminated busbar system is a composite component that consists of two primary materials, namely copper plate and sheet molded composite material. The copper bus bar is pressed into a sandwich bus system through sheet molded composite materials or epoxy materials.
After the use of thin copper plate, the heat dissipation area is increased a lot, the skin effect is small, and the amount of copper used is greatly reduced; For example, the 2mm thick copper plate, the width of the copper bar is 400mm, and the cross-sectional area is 800mm2, which can carry 2000A current, eliminating the dangerous exposure of the live busbar parts; The arc protection zone can ensure the safety of the protection personnel; Reduces the risk of arcing caused by mechanical failures, resulting in a significant reduction in protection and downtime moments; There are fewer bus parts than traditional switchgear; Fewer electrical connectors for maximum switchgear availability; Excellent cooling power, reducing heat emittion, saving power and reducing costs; Less space required – reduced switchgear footprint saves space; The connection between the laminated bus bar and the main busbar, the main bus adopts a tubular structure, 100mm outer diameter, 10mm pipe thickness, the laminated bus system and the main bus bar are connected by plugs, copper pipe slots, and bus contact system.
After the laminated bus system and plug-in contact system, the switch cabinet can complete the thin structure similar to that of a tablet computer, and the modular combination plug-in and unplug is safe and reliable.
|
More on that
|
Bus load forecasting method and characteristics - Wiener
Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load supplied by the main transformer of the substation to a relatively small power supply area, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the result is ...
|
|
Application advantages of industrial busway - Wiener
1. It has a modern beauty;
2. Small dimensions;
3. Strong and light weight, simple operation;
4. The connection is very simple (just like connecting water pipes, connecting sections through tees, elbows and other joints to make them into a system;
...
|
|
Busbar system in detail – Vernal
1. In the 60mm bus system, the square fuse type blocking switch can be directly hooked.
2. The 60mm bus system refers to the three-wire or four-wire bus spacing of 60mm.
3. Strip NH-fuse type load barrier switch with scale 00 ...
|
|
How to solve the fault of the busway
If there is a problem in the bus duct of the double bus wiring, it is necessary to pay attention to the operation mode of bus maintenance in the process of dealing with the problem, and if necessary, the bus maintenance should be stopped for a short time. After the bus voltage disappears, the dispatcher should immediately swing the switch (including the bus tie switch) that may call, and notify the operation team to ...
|
|
Busway installation method - Wiener
1. Busway horizontal device, the interval between the two brackets is ≯2500mm, and the interval between straight devices is ≯3600mm;
2. When the device bracket is straight, it should be drilled with the channel side plate and fastened with M6-M8 bolts.
3. In the process of installation construction, priority should be given to the power supply system, ...
|
|
Several faults of the Wiener bus system can be avoided
Cause of bus failure
1. The inner network of the bus insulator and the breaker sleeve caused by the dirty appearance
2. The voltage transformer installed on the bus and the current transformer between the bus and the circuit breaker fail
3. Reverse gate ...
|
|
Vernal fuse replacement method
1. Prepare for replacement. For example, construction personnel should wear labor protection equipment, such as insulating gloves.
2. Confirm the fault type. Check the distribution box with a test pen first, confirm that there is no leakage, and then open the distribution box door. Then use the voltage tester to detect the three-phase power supply, if the three-phase ...
|
|
Features of the use of closed busway - Wiener
Compared with other air-type busway, Wiener closed busway has many similarities in appearance, and its difference lies mainly in the shell, the structure of the closed busway is more distinctive, which also makes its use have certain advantages. As long as it is in contrast ...
|
|
Rectangular busbar, trough busbar, and tubular busbar analysis
The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...
|
|
Fuse selection method - Wiener busbar
1. Select the model of the fuse according to the circuit requirements and device conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses.
...
|
|
Wiener bus adapters are suitable for use with Siemens 3VA1 and 3VA2 circuit breakers
For the use of Siemens' new 3VA1 series circuit breakers in the 30Compact system with currents up to 160A, Wiener has developed an EQUES® bus adapter.
A spring-loaded base and high-performance internal power rails ensure safe connection to the circuit breaker.
advantage
...
|
|
Wiener fixed and busbar mounting
Precautions for the device
VDE 0660 Specification Section 107 / EN 60947-3 Specification / IEC 60947-3 Specification
3 poles are broken at the same time, double breakpoints.
Operator-independent, safe opening/closing, in position ...
|
|
What is the Wiener bus system
The Wiener bus system is a standardized system for bus spacing, which is used in low-voltage power supply and distribution switchgear, so that the bus can both conduct electricity and support electrical components. The system is divided into 40, 60, 100 and 185mm systems.
...
|
|
The technology of the main bus bar in the low-voltage open light cabinet - Winer
One of the characteristics of the Wiener low-voltage switchgear is the multi-functional busbar system. The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical devices. The role of the bus bar is to transmit electric energy with the, and the bus bar is the main equipment constituting the electrical wiring. ...
|
|
How to choose the right fuse - Wiener
1. Select the type of fuse according to the line requirements and installation conditions. Circuits with small capacity are semi-enclosed or enclosed without fillers; The selection of large short-circuit current has a packing closed type; Semiconductor component maintenance selection of quick fuses.
...
|
|
Precautions for installation of Wiener busway
1. Before the bus duct installation, it should be ensured that the electrical shaft, substation and distribution room, the decoration project of the place through which the bus duct passes, and the heating and ventilation project are all completed to ensure that the bus duct is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design. The functions of the busway are single ...
|
|
Difference Between Busbar and Cable – Vernal
When the busway has not been developed and introduced, the cable is still an indispensable figure in the low-voltage distribution system, when the busway system is introduced and widely used. Whether to choose the cable or the bus duct has become a topic of endless debate. So it's hard to say which of the two is better ...
|
|
Operating regulations for the use of busbars - Wiener
1. Charging to the bus should be carried out with a switch (bus tie, bypass or line switch) with snap-action maintenance that reflects various types of faults. Before charging the bus, it should be considered whether the system may be unstable if the charging bus trips, and if necessary, the active power flow of the relevant line can be reduced. ...
|
|
The advantage of closed busbar over open busbar is Wiener
1) Closing the bus duct can reduce the grounding fault, prevent the short circuit between the phases, and fundamentally eliminate the grounding fault caused by external moisture, dust and foreign objects, and improve the continuity of generator operation.
2) Eliminate the surrounding ...
|
|
Common Bus Application Considerations – Wiener
In the common DC bus system of multiple inverters, especially the common DC bus of inverters of different power levels, it is very important that the connection between the bus bars is maintained by fuses. When one of the inverter power equipment in the common bus is damaged by short circuit breakdown, the other inverter bus ...
|
|