Modern power supply lines play a very important role like the aorta of the human body, and if something goes wrong, it can have serious consequences. Before the 80s of the 20th century, many stable cables were used in modern construction. With the rapid development of cities, the power load of buildings has increased dramatically, and the limitations such as difficult to disconnect cables and small capacity have become more and more obvious. At this moment, the bus duct with large capacity and convenient branches is widely used in various modern constructions, rather than cables, so let's learn about the six advantages of bus ducts relative to cables in modern construction!
1. Large ampacity and low power loss
The maximum rated operating current of a single bus duct reaches 6300A, which can meet the power demand of the current large load. The maximum rated operating current of a single circuit cable is only 800 amps. The current carrying capacity of the busway is stable, which can avoid unnecessary power loss. The cables are placed in sealed trays in such a way that unnecessary power loss is added.
2. The cooling conditions are good, and the temperature rise is low
The busway is a flat conductor, and the gross insulation material is also a thermal insulation material, which uses air to conduct heat and emit heat, which is emitted through the outer part of the metal shell. Compared with round conductor cables and pre-branch cables, busway has the characteristics of good heat dissipation and low impedance.
3. Foldable and convenient, adaptable
The busway is easy to separate, and when adding equipment, you only need to add a pin box nearby. When adding capacity, simply replace the maintenance unit capacity inside the plug box. After disconnecting the prefabricated disconnect cable, it is necessary to add a long parallel cable between the distribution cabinet and the load from scratch, and it is necessary to block the power supply for normal operation. Faults can affect the safety of adjacent circuits.
Long service life and high safety function
The service life of the bus duct can be more than 30 years, and the operation is relatively safe. Because of the high short-term withstand current, it is possible to equip the plug box of the branch circuit with special maintenance devices such as fuses and circuit breaker maintenance, and there are fewer natural defects in the circuit. The life of the cable is barely more than 15 years, the line aging is simple and faulty, for the tap maintenance of each layer, the power distribution room must be operated and maintained alone.
The device is simple and the maintenance is less in the later stage.
The bus duct structure is small, occupies a small space, and is composed of a special device bracket, which does not require rated support. In routine maintenance, it is only necessary to measure the temperature rise of the shell, new bolts, wire boxes, etc. After the fault, only the faulty plug box needs to be replaced, and the power transmission and distribution of other equipment will not be affected. After decomposition, it can be reused. The cable placement structure is messy, the clear steamer needs to equip the cable tray, the underground routing needs to dig trenches, and the construction cost is high. After the fault occurs, the whole line should be stopped, the replacement cycle is long, and the loss is large.
6. Strong overload capacity and good constant temperature effect
The busway insulation material is made of materials with an operating temperature of more than 100 °C. For example, busway products use DuPont polyester film that is insulated at room temperature up to Class B 130. Together, the busway shell is made of metal, which is simple to burn and has good fire resistance. As mentioned above, compared with the current carrying capacity, safety, service life, energy saving, and convenience of installation, the busway has more advantages than cables. It is believed that in the near future, in industrial plants, high-rise buildings, commercial complexes, rail transit, etc., bus stadiums will be more widely used in our lives, rather than cables.
|
More on that
|
Rectangular busbar, trough busbar, and tubular busbar analysis
The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...
|
|
Vernal fuse replacement method
1. Prepare for replacement. For example, construction personnel should wear labor protection equipment, such as insulating gloves.
2. Confirm the fault type. Check the distribution box with a test pen first, confirm that there is no leakage, and then open the distribution box door. Then use the voltage tester to detect the three-phase power supply, if the three-phase ...
|
|
What is the difference between a Wiener busbar and a cable
The difference between busbar and cable
The busbar is used to gather current. Many power and power supply circuits are connected to the bus, through which the power is gathered and sent to each circuit. Therefore, the current carrying capacity of the bus bar is relatively large, and the current carrying capacity of the bus ...
|
|
185Power - The solution for the 185mm busbar system
Since the launch of the 185Power system in 2014, Wiener has continued to develop new connection technologies and fuse-type disconnector technologies for the 185Power system on the basis of the 185mm bus technology.
In addition to the application of 1600A below ...
|
|
Introduction to the advantages of busway - Wiener
The advantage of the busway is that its structural design is simple, it is composed of metal plates, which can connect the circuits together, so as to achieve the safe and reliable transmission of electric energy. In addition, its structural design can effectively assist in reducing the occurrence of short circuits, reducing heat loss, and can effectively ensure the power ...
|
|
Wiener Data Center Bus System
Although the service life cost of the busbar system is usually lower than that of the traditional wiring method, the busbar system still bears a considerable cost compared to other structural elements of the water supply and drainage or HVAC system.
In addition, customized busbars ...
|
|
220V DC Hazard of Bus System – Wiener
The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system.
In the DC system, the positive and negative poles of the DC are insulated from the ground, and when the ground of one pole is generated, there is no grounding current due to the fact that there is no grounding current.
|
|
Precautions for terminal block wiring - Wiener
1. The fastening wiring force should be moderate, avoid sliding the bolts and nuts with excessive force, and replace the bolts and nuts that have been slid in time, and prohibit the operation.
2. When tightening or loosening the screws with a screwdriver, it is necessary to force the screws to ...
|
|
The advantage of closed busbar over open busbar is Wiener
1) Closing the bus duct can reduce the grounding fault, prevent the short circuit between the phases, and fundamentally eliminate the grounding fault caused by external moisture, dust and foreign objects, and improve the continuity of generator operation.
2) Eliminate the surrounding ...
|
|
How to optimize the busbar system of the computer room - Wiener
In today's information society, the computer room is a very common equipment, so the most important thing in a computer room is the bus system, which is the center and skeleton of the power distribution of the entire computer room. Then a reasonable bus system will greatly improve the efficiency of the equipment room. So how do you optimize ...
|
|
Development of the busbar trunk system – Wiener
(1) Air-type busway
Since the mid-50s of the last century, represented by Beijing Baizhifang Airport Electrical Appliance Factory, the conductive row has been supported in the shell with insulating liner and insulated by air medium. The phase-to-phase distance is 50mm.
(2) Secret ...
|
|
Temperature rise requirements and safety of Wiener busway
With the rapid development of our economy and technology, the trend of urbanization is becoming more and more popular, and people's electricity consumption is also increasing. In this case, the busway has developed significantly, and the use of instead of cable has become the development trend of the times. Therefore, what are the requirements for the temperature rise of the busway and ...
|
|
Bus voltage non-system equipment failure and solution - Wienal
In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require the voltage to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, when the power grid is in practice, due to the change of active and reactive power output, the increase or decrease of electricity load, and the system wiring party...
|
|
Bus load forecasting method and characteristics - Wiener
Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load supplied by the main transformer of the substation to a relatively small power supply area, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the result is ...
|
|
The difference between metal busbar and closed busbar - EVOC
The nature is different
Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches.
Busway: It is a closed metal equipment composed of copper and aluminum busbars.
Different uses
Mother...
|
|
Tubular busbar structure layout - Wienal
1. The tubular bus is in the form of a split-phase fully insulated shielded copper tube bus.
2. The cylindrical capacitor structure is selected, and the voltage equalizing capacitor layer, the main insulation layer, and the bottom layer of the shielding street are set between the conductor and the insulating sheath, and the shielding grounding layer on the outside is connected to the grounding grid. The quantity of each layer is determined by the seller.
|
|
Conductor and bus welding requirements - Wiener
1. Before welding, it is necessary to check whether the welding equipment is defective, whether the grounding of the electrical equipment is reliable, and strictly abide by the "welder safety operation procedures" when welding.
2. Correct wires and busbars, and prohibit the use of handleless files.
...
|
|
Precautions for the operation of low-voltage cabinets - Wienal
1. To carry out work in all and part of the energized panels, the equipment should be overhauled and separated from the operating machinery and equipment with obvious markings.
2. The secondary winding of the voltage transformer and the transformer should have reliable grounding maintenance.
3. On the secondary circuit of the voltage transformer in operation...
|
|
Laminated busbar system – Wiener
In the power system, the bus connects the various current-carrying branch circuits in the power distribution device together, and plays the role of collecting, distributing and transmitting electric energy; According to the appearance and structure, the bus bar is roughly divided into three categories: hard busbar, soft busbar and closed busbar.
...
|
|
Composition of medium and low voltage bus protection - Wiener
On the medium and low voltage side of the main transformer, the bus tie switch and the original electromagnetic relay maintenance DC circuit of each outlet, the PLC is used for logical comparison to determine whether it is a fault in the maintenance area or a fault outside the area.
...
|
|