1. Requirements for civil engineering before installation

1) The foundation, structure, reserved holes and embedded parts all meet the design requirements of electrical equipment.

2) After the construction of the roof and floor slab is completed, there shall be no leakage.

3) After the indoor ground construction is completed, mark the ground leveling line on the well wall.

4) The strength of the base and structure to reach the permissible device.

5) The decoration work that may damage the installed busway has been completed.

6) Anti-theft measures should be adopted locally related to densely packed bus devices.

                                  Dense busbar installation – Wiener

2. Personnel selection and training before installation

1) The device, operation and protection of densely packed busbars should be carried out by professionals.

2) Professional workers should be aware of the device, structure, operation and hazards of the equipment: they should also be subjected to systematic training on how to power the equipment and conduct tests.

3. On-site delivery and equipment preparation

1) Check whether the products and accessories have arrived at the capital verification site, and draw up the installation plan.

2) Equipment required for densely packed bus device: 1000V insulation tester (recommended): 10-12, 17-19, 21-24 open end wrench, socket and torque wrench; Flat gentle cruciform screwdriver: horizontal: tape measure, hanging wire; Scaffold; Calabash; herringbone ladder; percussion drills; cutting machines; electric welding machine; bench drills; Copper processing equipment and temporary power supply.

4. Disassembly of bus bar and device operation

1) According to the final information acknowledged by the manufacturer orderer. Such as original graphics, trend charts, shoveling of obstacles and reserved positions.

2) Generally, the size of the reserved hole should be 50mm -100mm larger than the overall size of the bus duct. For special data, please refer to the drawing requirements.

3) The distance from the dense busbar to the wall and the pattern board is necessary to ensure that there is enough horizontal and gentle straight space in the installation and protection process.

4) Take precautions to avoid leakage, dust and heat sources from corrosive busbars.

5) Manufacture of dense busbar device hanger: first recognize the position, draw a thin line to simulate the direction, and then fix the device bracket. Note that it is necessary to recognize whether the fixture bracket is firmly fixed and does not damage the structure of the building.

6) Conduct an insulation test on the bus unit to be installed, and the test value can be installed within the qualified range.

7) When hoisting, please pay attention to personal safety and equipment safety precautions. Avoid personal injury and damage to dense busbars.

8) When the straight device is straight, there is generally no special situation from the bottom to the top of the section-by-section device; It is necessary to take appropriate protective measures against the installed busbars to avoid the incursion of foreign objects.

9) It is advocated that in the process of installation, before the busway is not used, the packaging can be retained on the busway, and the protection can be increased at the joint.

10) When articulation is carried out between busbar units, it is necessary to keep the appearance of the articulation device clean and the busbar pipes in the same straight line. Then tighten the bolts. Once the adapter is tightened, mark it with a paint pen to acknowledge tightening.

11) When the bus unit is connected to other equipment, it is necessary to completely disconnect the power supply, and it is necessary for the equipment to be reliably grounded.

12) In the process of installation, all plug-in interfaces of densely packed bus bars must be in a dry closed state, and plug-in box switches must be in a dry disconnected state. It is forbidden to plug or unplug the plug box when the power is on.

More on that
Busway installation waterproofing work - Vernal Busway installation waterproofing work - Vernal

Most of the bus duct is the design standard for indoor use, so even if the humidity in the indoor air is relatively high, it will not have much impact on the operation of the busbar, but the bus duct enters the water during the use of the busway, which will definitely cause a certain degree of impact.

Introduction to the Wiener 3-pole adapter Introduction to the Wiener 3-pole adapter

1、32590 EQUES®30Compact Bus adapter 32 A 1 adjustable support rail 45 x 160 with conductor AWG 10 (6 mm²) 2、32591 EQUES®30Compact Bus adapter 63 A 1 ...

Types of corrosion of Wiener tubular busbars Types of corrosion of Wiener tubular busbars

Tubular bus is a new type of equipment that is widely used in our current days, and it itself has the characteristics of high current, outstanding insulation and wide range of application, so we don't seem to be too worried about its function and role when using it. But there is one thing that needs to be ...

The main components of the Wiener bus system in the distribution cabinet are composed The main components of the Wiener bus system in the distribution cabinet are composed

The Wiener bus system is divided into 40mm, 60mm, 100mm and 185mm systems according to the upper and lower spacing between the copper bars, and the ship unloader distribution cabinet mainly adopts a 60mm rectangular bus system. This is shown in the figure below. The 60mm system provides maximum operating space and maximum current with its smallest external size.

What are the characteristics of the bus wiring method of the power system? What are the characteristics of the bus wiring method of the power system?

(1) Single bus wiring. Single bus wiring has the advantages of simplicity and clarity, less equipment, less investment, and convenient operation and expansion, but its reliability and activity are poor. When the bus or bus separator is faulty or overhauled, all power to the bus must be disconnected. ...

Busbar wiring problems of busbars - Vernal Busbar wiring problems of busbars - Vernal

Bus, transformer, generator set unit wiring. It has the characteristics of simple wiring, less switchgear, easy operation, suitable for expansion, and because there is no generator outlet voltage bus, the short-circuit current of the low-voltage side of the generator and the main transformer is reduced. ...

What is tubular busbar and dense busbar - Wiener What is tubular busbar and dense busbar - Wiener

What is a tubular busbar Tubular bus bar is a kind of bus bar product with copper tube or aluminum alloy tube as conductor and external insulation. The tubular bus has the characteristics of high current (12000A), high mechanical strength, good insulation, wide application range, etc., ...

Applications in the power of busbar systems – Vernal Applications in the power of busbar systems – Vernal

The bus refers to the connection of voltage transformers and other voltage distribution devices at all levels in the substation, as well as the connection of electrical equipment such as transformers and corresponding distribution devices, and most of the bare wires or stranded wires with rectangular or circular cross-sections are selected. Follow the lines ...

Vernal fuse core Siemens fuse alternative Vernal fuse core Siemens fuse alternative

Due to the long delivery time of the Wiener melt core, whether the Wiener fuse can be replaced by Siemens' fuse, the answer is yes, so it is recommended to use Siemens' Rong Xin, which corresponds to the following 3NA38012C NH-Fuse NH-,00(0 ...

The difference between metal busbar and closed busbar - EVOC The difference between metal busbar and closed busbar - EVOC

The nature is different Busbar: It is a common path on which multiple devices are connected in the form of side-by-side branches. Busway: It is a closed metal equipment composed of copper and aluminum busbars. Different uses Mother...

There are several main ways to wiring the Wiener bus There are several main ways to wiring the Wiener bus

Bus line refers to a product made of copper (copper bar) and aluminum material with high conductivity to transmit electrical energy and have the ability to collect and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the output of the generator, transformer or rectifier ...

Technical features of Wiener closed busbar Technical features of Wiener closed busbar

The out-of-phase shut-off bus adopts a fully connected structure, with optimized design, reasonable design, stable and reliable operation. Choose either natural cooling or forced air cooling. The out-of-phase closing bus is to support the conductors of each phase bus with insulators and close them in their respective shells, and the shells themselves are electrically connected, ...

Wiener enclosed busbar installation Wiener enclosed busbar installation

Closed busway is a busbar system composed of metal plates (steel plates or aluminum plates) as protective shells, conductive strips, insulating materials and related accessories. It can be made into a piercing closing bus with spaced piercing junction boxes, or a feed-in closing bus without a junction box in the middle. ...

Features of busway power supply system - Wiener Features of busway power supply system - Wiener

1. Trunk power distribution system, simple wiring and reliable operation. 2. It is convenient to tap, and you can tap without cutting off the main power supply. Large power supply capacity up to 6300A current-carrying capacity. 3. High dielectric strength, strong overload, superior fire performance. Good heat dissipation performance, low impedance ...

Bus voltage non-system equipment fault handling method - Wiener Bus voltage non-system equipment fault handling method - Wiener

In order to ensure the safe and economical operation of the power system and its power generation, supply and electrical equipment, power grid users require voltage separation to operate in three ways: forward voltage regulation, reverse voltage regulation and constant voltage regulation. However, in the actual operation of the power grid, due to the change of active and reactive power output, the increase or decrease of the electrical load, the system wiring party...

The technology of the main bus bar in the low-voltage open light cabinet - Winer The technology of the main bus bar in the low-voltage open light cabinet - Winer

One of the characteristics of the Wiener low-voltage switchgear is the multi-functional busbar system. The bus bar is a conductor that connects large electrical equipment such as generators and transformers with various electrical devices. The role of the bus bar is to transmit electric energy with the, and the bus bar is the main equipment constituting the electrical wiring. ...

Wiener plug-in busway features Wiener plug-in busway features

The plug-in busway has a high overload capacity The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105C is selected for the insulation material used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed ( ...

Temperature rise requirements and safety of Wiener busway Temperature rise requirements and safety of Wiener busway

With the rapid development of our economy and technology, the trend of urbanization is becoming more and more popular, and people's electricity consumption is also increasing. In this case, the busway has developed significantly, and the use of instead of cable has become the development trend of the times. Therefore, what are the requirements for the temperature rise of the busway and ...

Wiener busway plug-in box wiring method Wiener busway plug-in box wiring method

The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection. ...

Ferromagnetic resonance occurs in the busbar system – Vernal Ferromagnetic resonance occurs in the busbar system – Vernal

The ferromagnetic resonance of the bus system is divided into parallel ferromagnetic resonance and series ferromagnetic resonance. Parallel ferromagnetic resonance refers to the resonance of the ground capacitance of the bus system and the nonlinear inductance of the bus electromagnetic voltage transformer (primary neutral grounding) in the neutral point ungrounded system or small current grounding system.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top