Busbar system segmentation understanding - Wiener

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

The so-called "section" of the bus bar is that the data that constitutes the bus are directly connected, and there is no circuit breaker or blocking switch in the center. A circuit breaker or barrier switch in the center is called a "segment".

                            Busbar system segmentation understanding - Wiener

Different voltage levels cannot be connected in the same section. Different power supplies generally do not operate on the same bus section at the same time.

The center of the segmented bus is connected by a circuit breaker or barrier switch, but pay attention to the difference with the double bus or bypass bus.

The incoming and outgoing wires connected on the double bus or bypass bus are the same. For example, if the high-voltage side of a main transformer and each bus of the double bus are connected, if it is a segmented bus, one side of the same transformer will not be hung on the two buses.

More on that
Example of the application of the Wiener busbar system Example of the application of the Wiener busbar system

The motor control cabinet uses the Wiener bus system, and the copper bus is used as both a hooking element and a conductive element; The incoming molded case circuit breaker is connected to the copper bar through a special bus adapter, and all the motor maintenance switches and contactors are hooked on the bus adapter in an orderly manner.

Structural characteristics of high-voltage busway - Vernal Structural characteristics of high-voltage busway - Vernal

If you understand the scope of application of the busway, you can see that the excellent effect of the busway has the upper hand, which has a lot to do with the structural features. Therefore, if you want to have more confidence with the bus duct, you still need to understand it from the structural characteristics. At a time when China's economy is developing rapidly, ...

What are the common types of fuses - Wiener What are the common types of fuses - Wiener

Plug-in fuse: It is commonly used at the end of the line at the voltage level of 380V and below, as a short-circuit maintenance for distribution branch lines or electrical equipment. Spiral fuse: The upper end of the melt is covered with a fuse indicator, once the melt is melted...

Ferromagnetic resonance occurs in the busbar system – Vernal Ferromagnetic resonance occurs in the busbar system – Vernal

The ferromagnetic resonance of the bus system is divided into parallel ferromagnetic resonance and series ferromagnetic resonance. Parallel ferromagnetic resonance refers to the resonance of the ground capacitance of the bus system and the nonlinear inductance of the bus electromagnetic voltage transformer (primary neutral grounding) in the neutral point ungrounded system or small current grounding system.

Technical requirements for busway system – Wiener busbar Technical requirements for busway system – Wiener busbar

1. The conductor of the bus bar is a high conductivity TMY electrical hard copper bar rolled by T2 electrolytic copper, and the purity of copper must be ≥ 99.95%, and copper-aluminum alloy or other mixed alloy non-pure copper conductor materials shall not be used, and the copper plate is tin plated on the full length. 2. The raw material of the neutral wire and the phase wire in the bus system is the same.

Vernal fuse replacement method Vernal fuse replacement method

1. Prepare for replacement. For example, construction personnel should wear labor protection equipment, such as insulating gloves. 2. Determine the type of fault. Check the distribution box with a test pen first, and after making sure that there is no leakage, open the door of the distribution box. Then use a voltage tester to detect the three-phase power supply, if the three-phase ...

Low-voltage cabinets need temperature and humidity controllers for the reason - Vernal Low-voltage cabinets need temperature and humidity controllers for the reason - Vernal

Why is the temperature and humidity controller of the low-voltage cabinet? The application field of low-voltage cabinet is very wide, high-voltage switchgear should be one of the key electrical equipment and equipment for electromagnetic energy production scheduling and transportation, there will be some simple reasons to form high-voltage switchgear hot in specific work, low-voltage cabinet I remind you that at this time ...

Strip Switch vs. Disconnector Circuit Breaker Comparison – Wiener Strip Switch vs. Disconnector Circuit Breaker Comparison – Wiener

Bar switches are different from regular switches. They are critical to ensuring effectiveness. For example, when the current exceeds a certain amount of time, they cause heat to be generated, allowing the fuse to switch the fuse to further assist in breaking the circuit. Therefore, as a kind of current protection device, they can achieve ...

185Power - The solution for the 185mm busbar system 185Power - The solution for the 185mm busbar system

Since the launch of the 185Power system in 2014, Wiener has continued to develop new connection technologies and fuse-type disconnector technologies for the 185Power system on the basis of the 185mm bus technology. In addition to the application of 1600A below ...

Closed busway essentials – Wiener Closed busway essentials – Wiener

Before the closed busway device, it should be ensured that the electrical shaft, the transformer and distribution room, the decoration project of the place through which the busway passes, and the heating and ventilation project are all completed to ensure that the closed busway is not polluted. The reserved holes and embedded parts of the floor and wall should be embedded and reserved according to the position required by the design. ...

Protection of medium and low voltage busbars – Wienal Protection of medium and low voltage busbars – Wienal

There are three types of maintenance commonly used in medium and low voltage bus systems: (1) Transformer backup overcurrent maintenance (typical maintenance action time is 1.2s - 1.4s) (2) Transformer voltage with feeder quick-break maintenance locking ...

The main components of the Wiener bus system in the distribution cabinet are composed The main components of the Wiener bus system in the distribution cabinet are composed

The Wiener bus system is divided into 40mm, 60mm, 100mm and 185mm systems according to the upper and lower spacing between the copper bars, and the ship unloader distribution cabinet mainly adopts a 60mm rectangular bus system. This is shown in the figure below. The 60mm system provides maximum operating space and maximum current with its smallest external size.

Avoidable failures in busbar systems – Wienal Avoidable failures in busbar systems – Wienal

Cause of bus failure 1. The internal network of bus insulators and breaker sleeves caused by surface pollution 2. The voltage transformer installed on the bus and the current transformer between the bus and the circuit breaker are faulty 3. The support of the circuit breaker or isolation switch caused by the reverse operation ...

Wiener busway plug-in box wiring method Wiener busway plug-in box wiring method

The bus duct bracket has to be firmly installed, and the bus duct should be correctly placed according to the segment sequence number, phase sequence, number, direction and device mark, and when the sections are connected, the adjacent section of the bus duct should be aligned, and the conductor and shell of the bus duct should not accept mechanical stress after the connection. ...

Scope of application of busbar - Wiener busbar system Scope of application of busbar - Wiener busbar system

Busbars are divided into hard busbars and soft busbars. According to its different shapes, hard buses can be divided into: rectangular busbars, tubular busbars, trough busbars, diamond busbars and so on. Rectangular busbars are the most commonly used busbars and are also busbars. ...

220V DC Hazard of Bus System – Wiener 220V DC Hazard of Bus System – Wiener

The grounding of the DC system should include two situations: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of the DC are insulated from the ground, and when the ground of one pole is generated, there is no grounding current due to the fact that there is no grounding current.

220V DC Hazard in Busbar System – Wiener 220V DC Hazard in Busbar System – Wiener

The grounding of the DC system should include two conditions: the one-point grounding of the DC system and the two-point grounding of the DC system. In the DC system, the positive and negative poles of DC are insulated from the ground, and they do not cause any harm when generating a ground current because there is no path to constitute a grounding current, but the ground of one pole is long.

The advantage of busway over cable in construction - Wienal The advantage of busway over cable in construction - Wienal

Modern power supply lines play a very important role like the aorta of the human body, and if something goes wrong, it can have serious consequences. Before the 80s of the 20th century, many stable cables were used in modern construction. With the rapid development of the city, the power load of the building ...

Wiener plug-in busway features Wiener plug-in busway features

The plug-in busway has a high overload capacity The overload capacity of the bus duct is strong, depending on the high working temperature of the insulation material it uses, and the working temperature of 105C is selected for the insulation material used in the bus duct, and the radiation cross-linked flame retardant winding tape with a working temperature of more than 140 °C has been developed ( ...

Introduction to busbars, busway, and busbridges - Wiener Introduction to busbars, busway, and busbridges - Wiener

generatrix In the field of electricity, the busbar can also be called the busbar, busbar, etc., which mostly refers to the busbar or power supply trunk in the high and low voltage cabinet, which is used to connect multiple electrical lines. The system will install various interface cards through the bus, and transmit various data to the devices connected to the interface cards.

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top