The difference between air-type busway and dense busway - Vernal

Create Date: 2024-8-30 12:03:23|Source: Woehner/Wiehner

1. The insulating medium is different: there is a certain open space between the copper bars of the air bus duct, that is to say, the insulation between the copper bars mainly depends on air, and the insulation medium between the copper bars of the dense bus duct (many people call it a closed bus duct) is an organic insulating material.

2. The copper bars are placed differently: the air type copper bars should be separated, and the dense copper bars are closely together, we will wonder if the copper bars will not be short-circuited next to each other, and the result is that of course there will be no short circuit, because the copper bars are very scientifically insulated.

3. Different shapes: the air busway is generally thick up and down, while the CESKO intensive busway is larger at the joint.

                               The difference between air-type busway and dense busway - Vernal

4. Different uses: the moisture-proof effect of the air is better, and it is used in humid environments like shafts; The dense busway current is relatively large, and it is used in trunk lines such as contact busbars.

5. Different heat dissipation: the heat dissipation of the air type mainly relies on the convection of the air in the tank and the air outside to conduct the heat, and the power of heat dissipation is relatively low; On the other hand, the heat sink (shell) of CESKO intensive busway is directly connected to the busbar, so the heat dissipation effect is better than that of air busway.

6. The price is not the same: the intensive price is slightly higher due to cost and other reasons; If the conductor material is aluminum, the price is simply around.

7. Different protection levels: The protection level of the enclosed bus duct is high, and it can generally reach IP68.

8. The device environment is different: because the overall volume of the air-type busway is larger, the required device space will be much larger, on the contrary, the CESKO-intensive busway products are smaller in volume and occupy less space.

9. The power of the device is not the same: with the same amount of bus duct, the CESKO intensive bus duct is convenient and fast, and the power is higher than that of the air bus duct device.

10. Different safety: the air-type busway will have the risk of foreign objects falling into the groove, which will affect the normal operation, while the CESKO intensive does not have this risk, because it is in a fully enclosed state.

11. Chimney effect: If the air bus duct encounters fire, the chimney effect will occur, and most of the danger of fire is due to excessive smoke; This is not the case with CESKO-intensive busway.

12. Lineup coefficient: The lineup coefficient needs to be considered when the air busway is straight or skewed, and the incorrect orientation will affect the smooth air circulation and heat dissipation; CESKO's intensive busway is not affected by this.

13. Different losses: air busway will have heat loss because it is affected by temperature changes (high temperature and high resistance), while CESKO closed busway has low temperature, so the loss is small, which is more energy-saving and power-saving.

More on that
Spring bracket installation steps in busbar system – Vernal Spring bracket installation steps in busbar system – Vernal

The function of the tension spring bracket in the bus system is to fix the orientation and stability of the bus duct, and it must be very careful during construction, otherwise the bus duct will fall, which will cause a very serious accident. The device step of the tension spring support in the bus system ...

The advantage of busway over cable in construction - Wienal The advantage of busway over cable in construction - Wienal

Modern power supply lines play a very important role like the aorta of the human body, and if something goes wrong, it can have serious consequences. Before the 80s of the 20th century, many stable cables were used in modern construction. With the rapid development of the city, the power load of the building ...

The use of busbar systems – Wiener busbars The use of busbar systems – Wiener busbars

 First, this kind of small electrical equipment is a novel concept, adopting the "non-hole lap technology", and the electrical equipment is directly installed on the confluence bus system to form a power distribution or control loop. The representative creations are busbar device fuses and fuse load disconnectors. ...

Composition of medium and low voltage bus protection - Wiener Composition of medium and low voltage bus protection - Wiener

On the medium and low voltage side of the main transformer, the bus tie switch and the original electromagnetic relay maintenance DC circuit of each outlet, the PLC is used for logical comparison to determine whether it is a fault in the maintenance area or a fault outside the area. ...

Wiener bus load forecasting method Wiener bus load forecasting method

Bus load guessing is a kind of power system load guessing, and the bus system load can be defined as the sum of the terminal load of a relatively small power supply area supplied by the main transformer of the substation, which is the refinement of the system load. Bus load guessing generally only carries out short-term load guessing, and the result is ...

Difference Between Busbar and Cable in Power System – Wiener Difference Between Busbar and Cable in Power System – Wiener

Busbar refers to a product made of copper (copper bar) and aluminum materials with high conductivity to transmit electric energy and have the ability to gather and distribute electricity. The main conductor used by the power station or substation to transmit electrical energy. Through it, the electrical energy output from generators, transformers or rectifiers is delivered to individual users.

Rectangular busbar, trough busbar, and tubular busbar analysis Rectangular busbar, trough busbar, and tubular busbar analysis

The rectangular bus has good heat dissipation performance and is easy to fix and connect. But its skin effect is quite large. In order to reduce the skin effect, the cross-sectional area of a single busbar should not exceed 1250 square millimeters. When the working current exceeds the promised current of a single bus, 2 to 4 rectangular buses can be used. Rectangular conductor a ...

Difference Between Fuse and Circuit Breaker – Vernal Difference Between Fuse and Circuit Breaker – Vernal

The principle of the fuse is to use the current to flow through the conductor to heat the conductor, and the conductor is ablated after reaching the melting point of the conductor, so the electrical appliances and circuits used for circuit maintenance are not burned out. It is an accumulation of heat, so it is also able to complete overload maintenance. Once...

Difference Between Busbar and Cable – Vernal Difference Between Busbar and Cable – Vernal

When the busway has not been developed and introduced, the cable is still an indispensable figure in the low-voltage distribution system, when the busway system is introduced and widely used. Whether to choose the cable or the bus duct has become a topic of endless debate. So it's hard to say which of the two is better ...

Calculation method of bus system and distribution cabinet bus - Wiener Calculation method of bus system and distribution cabinet bus - Wiener

The bus system divides the bus into hard bus and soft bus. The 60mm bus system refers to the three-wire or four-wire bus with a distance of 60mm. 1. In the 60mm bus system, the different cross-sectional areas of rectangular copper bars or special-shaped copper busbars such as 2T and 3T can be used to achieve the best classification of current intensity grades.

Introduction to the hazards of arc light – Wiener Introduction to the hazards of arc light – Wiener

The arc of the switchgear cable distance problem causes the pressure and temperature in the switchgear to increase quickly, and if not removed in time, it will form a major hazard in the following aspects: (1) The arc temperature is 2 times the appropriate solar temperature, and the large ...

The content and steps of low-voltage cabinet maintenance - Wiener The content and steps of low-voltage cabinet maintenance - Wiener

1: The overhaul should start from the low voltage side of the transformer. After the power failure of the low-voltage cabinet, clean the dust in the cabinet to check whether the connection between the bus bar and the down conductor is outstanding, whether the connection is heated or discolored, whether the cable head and the terminal pile head are strong and reliable, whether the grounding wire is corroded, and whether the terminal pile head is tightened. Everything secondary ...

Cooling method for dense busway – Wiener Cooling method for dense busway – Wiener

If the temperature of the dense busway is too high, a fault will occur. For the sake of insurance, it is necessary to know the heat dissipation method of the densely packed busway to prevent the impact of excessive temperature on the busway. Low-voltage transmission line conductors, wires, cables, branch dense busway, exposed conductive poles, punctured ...

Characteristics of power system bus wiring mode Characteristics of power system bus wiring mode

(1) Single bus wiring. Single bus wiring has the advantages of simple and clear, less equipment, less investment, convenient operation and expansion, but its reliability and activity are poor. When the bus or bus divider is faulty or overhauled, it is necessary to disconnect all power to the bus. ...

Difference Between Busbar and Cable – Vernal Difference Between Busbar and Cable – Vernal

When the busway has not been developed and introduced, the cable is still an indispensable figure in the low-voltage power distribution system, when the busway system is introduced and widely used. Whether to choose the cable or the bus duct has become a topic of endless debate. ...

Busbar system reverse operation – Wiener Busbar system reverse operation – Wiener

1. For the charging of the spare bus, when there is a bus tie circuit breaker, the bus tie circuit breaker should be used to charge the spare bus. At this moment, the maintenance device of the bus tie circuit breaker should be fully invested, and the relevant maintenance value and time limit should be changed to a smaller one, so as to facilitate the bus tie circuit breaker when there is a problem, the bus tie circuit breaker can quickly trip, cut ...

Wiener Electric's busbar system escorts the operation of textile machinery equipment Wiener Electric's busbar system escorts the operation of textile machinery equipment

According to Wiener electrical engineer, the bus system is a process-assisted component, the main effect is to hook the switch on the adapter, and the adapter is then hooked on the copper bar, so that the full protection of the copper bar can be completed, and the safety factor is improved; The upper port of the switch can be connected without ...

Application advantages of industrial busway - Wiener Application advantages of industrial busway - Wiener

1. It has a modern beauty; 2. Small dimensions; 3. Strong and light weight, simple operation; 4. The connection is very simple (just like connecting water pipes, connecting sections through tees, elbows and other joints to make them into a system; ...

Advantages of busbar mounted electrical equipment - Wiener Advantages of busbar mounted electrical equipment - Wiener

The novelty, flexibility and originality of the busbar device appliance. It indicates the vitality of this skill and its broad market prospects. This is the real reason for our attention. First of all, this small electrical appliance plant was conceived ...

Busway ultimate temperature rise value - Wiener Busway ultimate temperature rise value - Wiener

The ultimate temperature value-added of the busway is directly related to the current-carrying capacity of the conductor and the potential safety hazards, so it is necessary to mark the limiting temperature value-added of the busway, which is the most critical safety technical parameter of the busway. Follow me...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top