A: A800 series inverters are generally used in heavy-duty occupations, such as lifting occupations, mixer occupations will use A800 series. At the same time, it is also a vector inverter, so customers can use the A800 series when they need to do closed-loop speed control, torque control or position control.
Q: What is the meaning of HD, ND, LD, SLD separation in the extra column of A840 selection sample?
A: HD: Heavy Load, ND: Normal Load, LD: Light Load, SLD: Ultra Light Load.
Q: How should Mitsubishi inverter A840 be selected (one belt and one belt)?
A: The selection method of Mitsubishi inverter is consistent with reference to additional capacity and additional current. Generally speaking, the additional current of a frequency converter with a motor is greater than 1.1 times of the additional current of the motor if the selection conditions are satisfied.
Q: How should Mitsubishi inverter A840 be selected (more than one belt)?
A: The selection method of Mitsubishi inverter is consistent with reference to additional capacity and additional current. Generally speaking, the additional current of a frequency converter with multiple motors is greater than 1.1 times of the sum of the additional currents of multiple motors. If the demand is started sequentially, an additional 6-8 times of the additional current of the final motor is added.
Q: Can the A840 inverter have a motor with the same power? Example: 7.5kw inverter with 7.5kw motor.
A: The selection method of Mitsubishi inverter is consistent with reference to additional capacity and additional current. The same power may not be completely compatible, we also have to verify whether the additional current of the inverter is satisfied, if the additional current of the motor X1.1 is greater than the additional current of the inverter, then there may be an overload alarm during operation, unable to work.
Q: Can the high-power A840 inverter be equipped with a low-power motor, and the power difference is large?
A: It is not appropriate for high-power inverter with low-power motor, if the difference in the power segment is too large, it will also produce an alarm of output phase loss (E.LF), the power difference is too much, if the maintenance parameters are not set properly, it will also produce the situation of burning the motor, so the selection is still rigorous, and the inverter and the motor must be matched.
Q: Can the low-power A840 inverter be equipped with a high-power motor?
A: The selection method of Mitsubishi inverter is consistent with reference to additional capacity and additional current. Generally speaking, the extra current of the low-power inverter will be less than that of the high-power motor, so this selection is not possible, and the selection still refers to the additional current of the inverter is greater than 1.1 times of the additional current of the motor, and the selection is carried out together with power and current.
|
More on that
|
Mitsubishi Electric expands 6th generation 1200V large-scale DIPIPM
Power semiconductor module for 40kW class commercial air conditioner
Expansion of the "6th Generation 1200V Large DIPIPM" product lineup
Mitsubishi Electric Corporation will sell the power of inverters that drive commercial air conditioners and other products on August 30.
|
|
Installation and maintenance of Mitsubishi inverters
1. Mitsubishi inverter is more and more widely used because of a series of advantages such as wide speed regulation range, high speed regulation accuracy, fast dynamic response, high work efficiency, convenient operation and easy interface with other equipment. Because of the high common sense content of Mitsubishi inverter and the messy technology, how to use Mitsubishi inverter well...
|
|
Mitsubishi PLCFX2NCPU plate fault solution
Customer's description of the problem: Mitsubishi FX2N-32MR-001, the PLC running light does not light up after powering on, and the alarm light is always on (hardware problem)
Inspection and repair: turn on the power supply, power on the PLC, according to the detection process, the PLC is in the POWER...
|
|
Troubleshooting methods for Mitsubishi overload
1. Check whether the motor is heated
If the temperature rise of the motor is not high, the first thing to check is whether the electronic thermal protection function of the Mitsubishi inverter is preset reasonably, if the Mitsubishi inverter still has margin, the preset value should be relaxed; For example, the allowable current of Mitsubishi inverter is now out of margin, not ...
|
|
Mitsubishi servo motor is now commonly used
1. Torque control: Torque control is based on external simulation simulation type or direct address assignment to set the output torque of the motor shaft. For example, 10V matches 5Nm. When the external simulation simulation is set to 5V, the output of the motor shaft is 2.5Nm. If the load on the motor shaft is less than 2.5Nm, ...
|
|
Introduction to Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. The CC-Link fieldbus connection greatly reduces the number of wirings and improves the maintainability of the system. Whereas...
|
|
Introduction to Mitsubishi PLC network structure
1. The equipment layer/fieldbus CC-Link equipment layer is a field network that connects PLC and other control equipment, sensors and drive equipment, which is the lowest layer of the entire network system. The CC-Link fieldbus connection is adopted, and the number of wiring is greatly reduced, and the maintainability of the system is improved. Combine...
|
|
Mitsubishi PLC selection 5 elements
Mitsubishi PLC selection - element 1: IO points
The number of ZUI IOs that can be accessed by the Mitsubishi PLC control system.
Mitsubishi PLC FX series now commonly used basic unit host is: FX1SFX1N, FX1NC, FX2N, FX2NC, FX3U. FX3UCFX3G, FX5U, 9 series.
...
|
|
The Mitsubishi QnUDVCPU module records the write function of the settings
The models of QnUDVCPU series products are Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, and Q26UDVCPU.
Data logging settings can be written to the target memory of the Mitsubishi QnUDVCPU module. When writing data recording settings, you should write data in the purpose of the writing settings.
|
|
Mitsubishi Electric develops satellites for greenhouse gas and water cycle observations
TOKYO, March 30, 2020 – Mitsubishi Electric Corporation (Tokyo: 6503) announced today that it has been appointed by the Japan Aerospace Agency (JAXA) as the contractor for the Global Satellite Observing Satellite for the Greenhouse Gas and Water Cycle (GOSAT-GW), the third satellite in the GOSAT series, ...
|
|
PLC commonly used physical memory - Mitsubishi
(1) Random Access Memory (RAM) The user can read out the content of the RAM with the programming device, and can also write the user program to the RAM, so the RAM is also called read/write memory. It is volatile memory, and when its power is interrupted, the stored information is lost. The use of the computer's memory module ...
|
|
Introduction to the Mitsubishi FX PLC Outage Service
1. What is suspension?
The so-called suspension refers to the fact that in the process of sequentially performing the program scanning, when there is a request to respond immediately, the scanning work performed at that time is immediately suspended, and the service work specified in the request is performed first. When the service job is complete, go back to ...
|
|
Mitsubishi Electric appeared at the 2021 China Smart Expo
From August 23 to 25, 2021, the 2021 China International Intelligent Industry Expo (hereinafter referred to as the Smart Expo) was held in Chongqing International Expo Center. Mitsubishi Electric (China) ...
|
|
Mitsubishi fx2n AC power supply · DC input table of discontinued replacement models
FX2N-16MR Discontinued Replacement: FX3U-16MR/ES Input: 8 DC 24V Drain Output: 8 Relay
FX2N-16MR-ES/UL Discontinued Replacement Model: FX3U-16MR/ES Input: 8 points DC24V drain/source output: 8 points Relay
FX2N-16MS ...
|
|
Mitsubishi PLC module model
FX3S-10MR/ES AC power supply · DC input type input: 6 points DC24V drain/source type output: 4 points relay
FX3S-10MT/ES AC power supply · DC input input: 6 points DC24V drain/source output: 4 points transistor drain type
FX3S-10MT/E ...
|
|
Performance comparison of Mitsubishi servo motors
First, the control accuracy is different
The step angle of the two-phase hybrid Mitsubishi servo motor is generally 1.8 ° and 0.9 °, and the step angle of the five-phase hybrid Mitsubishi servo motor is generally 0.72 ° and 0.36 °. Mitsubishi servo motors are also smaller in some functions according to the segmentation. Such as Sanyo ...
|
|
Capacitive action in Mitsubishi inverters
Introduction to the names and effects of capacitors in different circuits
Capacitor is a kind of energy storage element, with the characteristics of "straight through AC, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand ...
|
|
The connection of the Mitsubishi inverter FR-A800
The connection of the Mitsubishi inverter FR-A800
|
|
Advantages of Mitsubishi Electric fresh air system
Mitsubishi Electric's fresh air system realizes indoor ventilation, but of course, we can't just be limited to simply replacing the outdoor air into the room, a good fresh air should filter the harmful substances in the air, so that the air entering the room is not only fresh, but also clean and harmless.
...
|
|
Mitsubishi AnS series analog module bias and gain applications
In today's industrial field, when using analog-to-digital conversion or digital-to-analog conversion, most of them do not only use the standard input characteristics of -10V-+10V, 0-20mA, but according to the practical voltage and current values to do the process requirements, then it is necessary to do the AD or DA module ...
|
|