Capacitive action in Mitsubishi inverters

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

Introduction to the names and effects of capacitors in different circuits

Capacitor is a kind of energy storage element, with the characteristics of "straight through cross, low frequency through high frequency", people in order to know and identify the capacitor in different circuits, according to its effect in the line and give it many names, understand these names and effects, to read the map is to help. Here's what some common names mean.

                               Capacitive action in Mitsubishi inverters

1. Filter capacitor

It is connected between the positive and negative poles of the circuit to remove the useless communication current in the circuit, and large-capacity electrolytic capacitors are generally selected, and other fixed capacitors are also selected.

2. Decoupling capacitor

It is connected between the positive and negative poles of the circuit to prevent the parasitic vibration caused by the positive reaction path formed by the internal resistance of the power supply.

3. Coupling capacitor

It is connected between the signal source and the signal processing circuit or two-stage amplifier to separate the direct current, so that the communication current or pulsating signal passes through, so that the DC operation point of the trusted amplifier does not affect each other.

4. Bypass capacitor

It is connected to both ends of the resistor or directly from a certain point to the common telecom, which sets up a path for the communication or pulsation signal in the AC and DC signals to prevent the voltage drop of the communication components when passing through the resistor.

5. Neutralize the capacitance

It is connected between the base and collector of the triode and is used to overcome the self-excited vibration caused by the capacitance between the transistor poles.

6. Groove capacitor (tuned capacitor)

Capacitors connected to both ends of a resonant circuit or vibrating circuit.

7. Pad the capacitor

In the circuit, the frequency scale of the vibration signal can be reduced, and the capacitance of the vibration frequency at the low frequency end is significantly improved, which is connected in series with the main capacitor of the groove.

8. Compensate capacitance

In the vibration circuit, the capacitor that expands the frequency scale of the vibration signal is connected in parallel with the main capacitor to provide an auxiliary effect.

9. Reverse path capacitor

It is also connected between the collector and the emitter of the row output tube, and is used to generate the reverse path of the line scan sawtooth wave.

10. Self-bootstrap boost capacitor

Its energy storage is used to increase the potential of the circuit so that its potential value is higher than the power supply voltage that supplies power to that point.

11. "S" calibrate capacitor

It is connected in series in a deflection coil circuit and is used to correct the extension distortion on both sides.

12. Frequency stabilized capacitor

In a vibration circuit, a capacitor used to stabilize the vibration frequency.

13. Punctual capacitor

In the RC punctuality circuit, it is connected in series with the resistor R to determine the length of the capacitor.

14. Step-down current-limiting capacitor

It is connected in series in the communication circuit and is used to divide the voltage and limit the current of the capacitive reactance of the communication electric.

15. Shorten the capacitance

This capacitor is a capacitor that is connected in series in UHF high-frequency heads to shorten the length of the vibration inductance.

16. Clapped capacitors

In a capacitor three-point vibration circuit, the capacitor connected in series to the vibrating inductor coil improves frequency stability due to the influence of the capacitor of the transistor junction of the water transport.

17. Thira capacitors

In a capacitor three-point vibration circuit, the capacitor connected to both ends of the vibrating inductor coil is made easier to vibrate at a vibration frequency in order to eliminate the influence of the transistor junction capacitance.

18. Speed up the capacitance

It is connected to the vibration reaction circuit to accelerate the positive reaction process and improve the vibration fluctuations.

19. Pre-weighted capacitance

In order to prevent the attenuation or loss of the high-frequency components during the modulation of the audio modulation signal, the capacitance in the RC network of the high-frequency components should be appropriately increased.

20. De-weighted capacitance

The pre-increased high-frequency component of the audio signal is attenuated along with the noise, and the capacitance in the RC network is restored to the original appearance of the accompanying signal.

21. Amplitude stabilization capacitance

In the frequency discriminator, it is used to stabilize the output signal fluctuations.

22. Spot reduction capacitance

In CRT subassembly circuits, capacitance is used to eliminate shutdown highlights.

23. Phase-shifting capacitance

A capacitor used to change the phase of a communication electrical signal.

24. Reaction capacitance

The capacitor 25, the soft-start capacitor that is used to react to the signal at the input and output terminals of the amplifier

It is usually connected to the base of the power switch to prevent the inrush current or voltage added to the switch base when the machine is turned on and the switch tube is too large and damages the switch.

26. Starting capacitor

It is connected in series to the secondary winding of the single-phase motor, and the phase-shifting communication current for the starting of the secondary winding of the motor is supplied, and the motor is disconnected from the secondary winding when it is working normally.

27. Working capacitor

It is connected in series to the secondary winding of the single-phase motor, and the phase-shifting communication current is supplied to the secondary winding of the motor, and the secondary winding is still in series in the circuit when the motor is working normally.

More on that
Mitsubishi PLCFX3U positioning control Mitsubishi PLCFX3U positioning control

Origin regression command with DOG lookup function Mitsubishi PLCFX3U origin regression command with DOG lookup function: DSZR. 1. The workbench runs in the direction of the value reduction of the current value register (generally runs in the opposite direction M8342 ...

The role of PLC power module - Mitsubishi The role of PLC power module - Mitsubishi

Internal memory programs, logic operations, sequential manipulation, punctuality, counting, arithmetic operations, and other programmable memories are used to manipulate a variety of machinery or production processes with digital or analog inputs/outputs. PLC-related peripherals should be easy to operate with industry to form a whole, easy to expand...

Mitsubishi fx2n AC power supply · DC input table of discontinued replacement models Mitsubishi fx2n AC power supply · DC input table of discontinued replacement models

FX2N-16MR Discontinued Replacement: FX3U-16MR/ES Input: 8 DC 24V Drain Output: 8 Relay FX2N-16MR-ES/UL Discontinued Replacement Model: FX3U-16MR/ES Input: 8 points DC24V drain/source output: 8 points Relay FX2N-16MS ...

Advantages and disadvantages of different output types of PLC – Mitsubishi Advantages and disadvantages of different output types of PLC – Mitsubishi

The three output types of PLC are: transistor output, thyristor output and relay output, what is the difference between these three different output types? (1) Transistor output: The big advantage is that it is accustomed to high-frequency action, and the echo time is short, generally about 0.2ms, but ...

Maintenance method of Mitsubishi inverter Maintenance method of Mitsubishi inverter

Electrical characteristics view Mitsubishi inverters that have been running and placed for a long time, due to the influence of the environment and the aging of inverter equipment, it is necessary to check and maintain the electrical performance of Mitsubishi inverters regularly. A comprehensive review of the input, rectifier and inverter, DC input fuses found ...

Mitsubishi inverter FR-E700 series is selected Mitsubishi inverter FR-E700 series is selected

Q: When will I choose the E740 series inverter? A: E700 is an economical and small inverter with high driving performance, with the function of holding the brake, and can also add options to expand the function, which can be used for transportation, lifting occupations, and has high cost performance. Q: Mitsubishi inverter E740 should ...

Mitsubishi PLC module model Mitsubishi PLC module model

FX3S-10MR/ES AC power supply · DC input type input: 6 points DC24V drain/source type output: 4 points relay FX3S-10MT/ES AC power supply · DC input input: 6 points DC24V drain/source output: 4 points transistor drain type FX3S-10MT/E ...

Introduction to Mitsubishi tension controllers Introduction to Mitsubishi tension controllers

1. Tension Manipulator Principle - Introduction The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, which is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the fact that human beings can ...

Mitsubishi servo motor method Mitsubishi servo motor method

1. Torque control: Torque control sets the output torque of the motor shaft through external imitation input or direct address assignment. For example, 10V is equivalent to 5Nm. When the external analog is set to 5V, the output of the motor shaft is 2.5 Nm. If the motor shaft load is less than 2.5 Nm, when the external load is 2.5 N...

Mitsubishi PLC set and reset command use example Mitsubishi PLC set and reset command use example

1 SET Directive The SET instruction is called an enthronement instruction. Its function is: to drive the coil, so that it has a self-locking function, and insists on the connection condition. In the diagram, when the moving contact X0 is closed, the SET command is executed to turn on the Y0 coil. After X0 is disconnected, the Y0 coil continues to insist on the ON condition, ...

The relationship between torque and performance of Mitsubishi servo motors The relationship between torque and performance of Mitsubishi servo motors

1. Additional torque The torque that occurs on the motor shaft under additional voltage, extra load is called the extra torque of the motor. 2. Starting torque The torque generated by the motor at the moment when a voltage is applied to the motor in a stopped condition is called the starting torque. The starting torque characterizes the electrical...

One-button adjustment function for Mitsubishi servo motors One-button adjustment function for Mitsubishi servo motors

After the first installation of different servo motors on the machine, they may be poorly matched to the machine during operation, resulting in vibration, noise and other phenomena. The cause of the problem is a mismatch between parameters such as the rigidity of the servo motor and the load-inertia ratio and the machinery. Due to the large number of parameters that affect ...

PLC Processor Performance Test – Mitsubishi PLC Processor Performance Test – Mitsubishi

The processor performance test should be carried out in accordance with the requirements of the system manual, to ensure that the system has the function described in the manual, and is stable and reliable, including the system communication, backup battery and other special modules to view. Redundancy testing is necessary for systems with redundant equipment. i.e. the redundant design ...

How does Mitsubishi PLC work? How does Mitsubishi PLC work?

1. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting. 2. Each scan process. The convergence samples the input signal. The convergence rewrites the output signal. 3. The inner ...

The cause of the failure caused by OC - Mitsubishi inverter The cause of the failure caused by OC - Mitsubishi inverter

1. Aging of drive circuit Due to the long-term use, it will inevitably lead to the aging of components, and then cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm often appears as soon as it is running. ...

Mitsubishi takes instructions and outputs instructions Mitsubishi takes instructions and outputs instructions

1) LD (take instruction) A command to connect a normally open contact with the left bus, and every logic line that starts with a normally open contact is used with this instruction; 2) LDI (Reverse Instruction) A normally closed contact is connected to the left bus to the instruction, each ...

Mitsubishi Electric Solutions serves the entire process of lithium battery production Mitsubishi Electric Solutions serves the entire process of lithium battery production

Mitsubishi Electric's MES system MELNAVI has a standard database, which can meet the needs of the 11 major functions required by MES, and also supports flexible secondary development, which can easily connect the upper ERP and lower automation products in a short time, and can also be connected to other APS scheduling software and analysis systems. ...

Built-in time adjustment in Mitsubishi PLC Built-in time adjustment in Mitsubishi PLC

How do I adjust the built-in moments in my Mitsubishi PLC? In the case of Mitsubishi PLC, sometimes technical engineers forget to adjust the PLC well, but they also need to pay attention to some key points and introduce how to adjust the built-in moments in Mitsubishi PLC. ...

Mitsubishi tension controller principle Mitsubishi tension controller principle

1. Tension Manipulator Principle - Introduction The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the human ability to ...

Mitsubishi low-power Z024 series inverter failure OC cause Mitsubishi low-power Z024 series inverter failure OC cause

(1) Aging of the drive circuit Due to the use of a long period of time, it will inevitably lead to the aging of components, which will cause the drive waveform to be distorted, and the output voltage will be unstable, so OC alarm will often appear as soon as it is running. ( ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top