The Mitsubishi QnUDVCPU module records the write function of the settings

Create Date: 2024-8-30 12:03:23|Source: Mitsubishi Electric/Mitsubishi Electric

The models of QnUDVCPU series products are Q03UDVCPU, Q04UDVCPU, Q06UDVCPU, Q13UDVCPU, and Q26UDVCPU.

Data logging settings can be written to the target memory of the Mitsubishi QnUDVCPU module. When writing data logging settings, the data logging to the destination of the writing settings should be stopped. In addition, if you write to the public settings, all data records are stopped.

First, the operation process

1. The "Online Operation (Write Logging Setting)" screen is displayed.

[Online] [Write Logging Setting]

2. Select the memory that stores the written data from "Target memory".

3. Select the "Target logging setting data" to write target data.

4. Click the "Write" button.

[Points]

. If there is data in the CPU module before writing, the data with the same setting as the common setting and the data being written will be overwritten.

Data other than the above will still remain in the CPU module. As a result, the data that is written is sometimes inconsistent with the data that was written.

. If the long-distance password input screen is displayed, enter the set password.

. If the automatic recording function is set to useful, the data recording file transmission function cannot be used.

Therefore, it should be recognized that the automatic recording function is not in a useful state before writing.

2. Set up the screen

                                  The Mitsubishi QnUDVCPU module records the write function of the settings

3. Set up the project

Common settings must be written to the CPU module before data logging can be performed.

1. Data recording settings

The data record setting is displayed as "Set No. [Data record name] (record type, file transfer setting status)".

2. The display of public setting data

The appearance of public data settings varies depending on the target memory.

· Specification ROM: Only the "buffer memory capacity setting" is displayed.

· SD memory card: "Buffer memory capacity setting" and "Auto recording setting (automatic recording setting status)" are displayed.
More on that
Mitsubishi FX2N Series Extended PLC Module Selection Chart Mitsubishi FX2N Series Extended PLC Module Selection Chart

Mitsubishi servo controller AL512 alarm Mitsubishi servo controller AL512 alarm

1. The acceleration and deceleration time constants are at fault. Solution: Increase the acceleration and deceleration time constants to check whether it is normal. 2. The torque constraint value is abnormal. Solution: Increase the torque constraint value to investigate whether it returns to normal. ...

How does Mitsubishi PLC work? How does Mitsubishi PLC work?

1. A scanning cycle is divided into input sampling, program fulfillment, and output rewriting. 2. Each scan process. The convergence samples the input signal. The convergence rewrites the output signal. 3. The inner ...

Mitsubishi FX1N switching power supply fault repair Mitsubishi FX1N switching power supply fault repair

Problem description: The power supply of the Mitsubishi FX1N-60MR-001 has no display (the safety guard, filter, temperature protection element, and rectifier are damaged). Inspection and repair: After the PLC is connected to the power supply, the power indicator (POWER light) does not light up.

Introduction of Mitsubishi PLC series Introduction of Mitsubishi PLC series

1. Main substrate There are a variety of models such as Q32SB, Q33SB, Q35SB, Q33B, Q35B, Q38B, Q312B and other main substrates for Q series PLC, and the meaning of the model is as follows: In the meantime, the "S" stands for ultra-thin main substrate, and only Q61SP power modules can be used, and they cannot be ...

Anti-interference measures for PLCs and touch screens - Mitsubishi PLC Anti-interference measures for PLCs and touch screens - Mitsubishi PLC

1. Select the power supply with excellent performance and press the disturbance introduced by the power grid The power supply of the PLC controller is powered by a non-power line, and is powered by a special line directly led by the main bus of the low-voltage distribution room. Isolation transformer should be selected, the transformer capacity should be 1.2-1.5 times larger than the actual need, and can be used in isolation...

Mitsubishi touch screen GT10 series models and their features Mitsubishi touch screen GT10 series models and their features

GT1020 touch screen ● The palm is large, the wide screen displays, and the ultra-small size is 3.7 inches ●3-color LED backlight for added visibility ●High brightness liquid crystal, clear under light ● Resolution 160×64, standard memory 512K ●Inside ...

Mitsubishi tension controller principle Mitsubishi tension controller principle

1. Tension Manipulator Principle - Introduction The tension manipulator can be called the tension manipulator, which is usually used with magnetic particle brake, magnetic particle clutch and tension detector, and is suitable for winding, unwinding, tension control, etc. It also has the so-called manual control function, which generally refers to the human ability to ...

Mitsubishi PLC login password setting operation Mitsubishi PLC login password setting operation

Method 1 1. Hit the PLC from RUN to STOP Mitsubishi's PLC has a special method of setting landing keywords, and it is necessary to ensure that the PLC is in a state of shutdown in order to successfully write the landing keywords. In the run running condition, the performance of the write will appear "Unable to ...

Mitsubishi FX3u interrupts the location command Mitsubishi FX3u interrupts the location command

The main effect of aborting the positioning instruction is that in some machine tools, when we give the abort signal and can walk to the distance we set, for example, if the mechanical structure needs to use the sensor to determine the position to go, you can use the abort positioning instruction to do, when the induction gives the abort.

Mitsubishi PLC commonly used model features Mitsubishi PLC commonly used model features

FX Series PLC: The FX3G PLC has a built-in large-capacity program memory, 32K steps, and the basic instruction processing speed can reach 0.21μs in standard mode. In the meantime, the FX series 5U is suitable for any industry, and is widely used by small and medium-sized enterprises. For example, this year's very popular mask machine is suitable for FX5U, and he can ...

Mitsubishi inverter setting parameter adjustment method Mitsubishi inverter setting parameter adjustment method

Mitsubishi inverter has many setting parameters, each parameter has a certain selection scale, and the inverter can not work normally due to improper setting of a single parameter in the application. Let's take a look at the Mitsubishi inverter parameter setting operation. ...

Troubleshooting methods for Mitsubishi overload Troubleshooting methods for Mitsubishi overload

1. Check whether the motor is heated If the temperature rise of the motor is not high, the first thing to check is whether the electronic thermal protection function of the Mitsubishi inverter is preset reasonably, if the Mitsubishi inverter still has margin, the preset value should be relaxed; For example, the allowable current of Mitsubishi inverter is now out of margin, not ...

PLC Processor Performance Test – Mitsubishi PLC Processor Performance Test – Mitsubishi

The processor performance test should be carried out in accordance with the requirements of the system manual, to ensure that the system has the function described in the manual, and is stable and reliable, including the system communication, backup battery and other special modules to view. Redundancy testing is necessary for systems with redundant equipment. i.e. the redundant design ...

Explanation of Mitsubishi pIc source type and drain type Explanation of Mitsubishi pIc source type and drain type

The source type is the power supply of the device, which has an input drive source and an output point with a power supply; Drain type means that the device does not have its own power supply, and the drive of the input point requires an external power supply, and the output is only a passive contact signal. The general input points are ...

Electronic gear ratio calculation for Mitsubishi servo motors Electronic gear ratio calculation for Mitsubishi servo motors

When calculating the electronic gear ratio of the Mitsubishi servo motor, the first thing to pay attention to is to check whether your Mitsubishi servo motor has been directly set to XX pulse one turn, if this parameter is not directly set, we can go through a simple formula to calculate the electronic gear ratio of the Mitsubishi servo motor. ...

Mitsubishi PLC control inverter method Mitsubishi PLC control inverter method

1. Mitsubishi PLC's analog signal control inverter Hardware: FX1N, FX2N PLC hosts, equipped with 1 simple FX1N-1DA-BD extended analog output board; or analog input-output hybrid module FX0N-3A; or FX2N-2DA with two outputs; or four outputs ...

How to write a holding circuit for Mitsubishi PLC How to write a holding circuit for Mitsubishi PLC

There is a very common kind of circuit in Mitsubishi PLC - the persistence circuit. The insistence circuit means that when the external input switch is a button, it can be pressed once through the insistence circuit to insist on the output, similar to the self-locking in the electrical diagram. We use Mitsubishi PLC as an example to write a sticking circuit. ...

Z series and A200 series inverter fault solving Z series and A200 series inverter fault solving

Low-power Z024 series inverter, our common problems include OC, ERR, no appearance, etc. There are two possible causes of OC. (1) Aging of the drive circuit Because the use of a long period of time will inevitably lead to the aging of components, which will cause the driving waveform to occur.

The difference between the measurement of ordinary motors and inverter motors - Mitsubishi The difference between the measurement of ordinary motors and inverter motors - Mitsubishi

1. The actual output waveform of the inverter is PWM wave, which contains carrier signals in addition to the fundamental wave. The carrier signal frequency is much higher than that of the fundamental wave, and it is a square wave signal, which contains a lot of higher harmonics, and the test system requires a higher sampling frequency and bandwidth. ...

CATEGORIES BYPASS
Customer Service Center

Online Consultation:QQ


ContactContact

Contact: Manager Huang

Contact QQ: 3271883383

Contact number: 13522565663


Scan the code to add WeChat (please save the picture first on the mobile phone)

working hoursworking hours

Weekdays: 9:00-17:00

Holidays: Only emergencies are handled

Contact us

Contact us

Contact number QQ consultation
QQ consultation

3271883383

Company address
Back to top